Filter Results By:

Products

Applications

Manufacturers

Showing results: 166 - 180 of 289 items found.

  • Channel Emulator

    ACE9600 - dBm

    The dBm Advanced Channel Emulator (ACE) is the most advanced non-terrestrial RF channel emulation solution to date. The emulated impairments include delay, signal Doppler, attenuation, phase offset, AWGN, frequency hopping, payload and multipath fading. The instrument can house up to four 600 MHz instantaneous bandwidth channels.

  • High Impedance Active Probes

    34A - Picoprobe

    Engineered to meet the stringent demands of advanced high frequency circuit designers. This high impedance probe combines full DC capability, rise/fall times of 120 ps, and a nominal loading input impedance of 10 megohm shunted by 0.1 pf. Signal attenuation is 20:1 with a 50 ohm oscilloscope input.

  • Programmable Step Attenuator, DC to 4 GHz, 0 to 11 dB, 1 dB steps

    8494G - Keysight Technologies

    The Keysight 8494G dc to 4 GHz programmable step attenuator offers exceptional repeatability and reliability. Attenuation is provided in 1 dB steps from 0 to 11 dB. Precision gold-plated leaf springs ensure long-life (over 5 million cycles) and very high attenuator repeatability (typically 0.01 dB). To improve measurement accuracy, NIST traceable data (SWR and attenuation) is available as Option UK6. A maximum switching time of 20 ms (including contact settling) speeds automatic testing. Custom step attenuator/switch combinations are possible. The Keysight 11716A/B/C interconnect kits provide quick connection of Keysight 8494/5/6/7 1 dB and 10 dB step attenuators in series for greater dynamic range with 1 dB steps.

  • Programmable Step Attenuator, DC to 26.5 GHz, 0 to 11 dB, 1 dB steps

    84904K - Keysight Technologies

    The Keysight 84904K programmable step attenuator offers coaxial measurements to 26.5 GHz in a compact, rugged design. It offers repeatability of better than 0.03 dB, excellent life (greater than 5 million switching cycles per section) and attenuator range of 0 to 11 dB in 1-dB steps. This latest design evolution sets new standards for size and performance. High attenuation accuracy and low SWR are achieved through the use of miniature thin-film attenuation cards composed of high-stability tantalum nitride film of saphire substrate. Insertion loss is outstanding, with less than 2 dB of loss at 26.5 GHz. The compact size of the unit, 35% smaller than the Keysight 8495/7 (26.5 GHz) family, allows for easy integration into instruments and ATE systems.

  • T3DSO Passive Probe, 350 MHz, 10X, 10 MOhm, 300V/600V

    T3PP350A - Teledyne LeCroy

    Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.

  • T3DSO Passive Probe, 350 MHz, 1X/10X, 1 MOhm/10 MOhm, 300V/600V

    T3PP350 - Teledyne LeCroy

    Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.

  • 500 MHz Passive Probe for WaveJet Touch, 10:1, 10 MOhm

    PP006D - Teledyne LeCroy

    Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.

  • 10:1 500 MHz 10 MOhms Passive Probe

    PP005A - Teledyne LeCroy

    Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MO. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.

  • Series Two Channel Low Pass Filter

    SR600 - Stanford Research Systems, Inc.

    The SR600 series consists of three dual-channel instruments. Each instrument channel has a low-noise preamplifier, a precision high pass or low pass filter section, and an output amplifier. The filters are 8-pole, 6-zero elliptic-type with 115 dB per octave rolloff, 0.1 dB of passband ripple, and 80 dB of stopband attenuation. 

  • Remote Control Panel For Outdoor SSPAs

    RCP2-1000-CO - Teledyne Paradise Datacom

    The Teledyne Paradise Datacom RCP2-1000-CO remote control panel allows the operator to monitor and control a remoteCompact Outdoor or High Power Outdoor SSPA.The control panel features a color touchscreen display and anintuitive menu structure. Adjustments to the attenuation leveland changes to the mute state can be made with a few taps onthe touchscreen.

  • Optical Variable Attenuator

    TW3303 - Techwin(China) Industry Co., Ltd

    The Perfect Handhold Tester Series Optical Variable Attenuator TW3303 TW3303 handhold optical variable attenuator is used for continuously variable optical signal attenuation. As the attenuator is used in the laser system for the on-line testing, there, thereforeTW3303 can be used in the digital system of communication devices (such as: PHD, SDH) and also in the system of adopting analog modulation (CATV

  • OTDR w/ Automatic Measurement Mode

    TW3100 - Techwin(China) Industry Co., Ltd

    Features:Automatic Measurement Mode: Only by selecting the measurement wavelength, the measurement parameters are automatically set, and the trace data is automatically saved and automatically analyzed. Multi-wavelength Measurement Mode: In the parameter setting, the wavelength can be automatically switched into the multi-wavelength measurement mode. Under this mode, the analysis can be achieved on the attenuation state of the same fiber section under different wavelengths.

  • RF Reference Sources

    Fluke Calibration

    The 27 GHz 96270A and 4 GHz 96040A Low Phase Noise Reference Sources are designed specifically for RF calibration, featuring a calibration-oriented interface, precision signal level and attenuation, high signal purity and precision low distortion modulation. Both instruments simplify the process of RF calibration by reducing the amount of equipment and simplifying the calculations required.

  • "Standard" RF Low Pass Filters

    Coaxial Dynamics

    Coaxial Dynamics "Standard" line of RF Low Pass Filters offers several models to choose from at CW power ratings of 100 watts and 200 watts. These filters cover operating frequencies from 88 MHz to 400 MHz with less than 0.5 dB insertion loss and attenuation levels of 40, 50 and 60 dB.

  • Variable Attenuator

    VAXE - Elmika

    The VAXE Variable Attenuators are waveguide components for tunable signal leveling or reflection compensation in waveguide networks. The Attenuators consist of waveguide section with a resistive film evaporated on the mica surface. The Attenuators has 0 ÷30 dB minimum attenuation range. The VAXE Attenuators are available in four waveguide bands between 33 GHz and 170 GHz.

Get Help