Filter Results By:

Products

Applications

Manufacturers

Atmosphere

1) a planet's exosphere, surface to space, space. 2) a unit of atmospheric pressure.

See Also: Atmospheric, Air, Earth, Climate, Space


Showing results: 91 - 101 of 101 items found.

  • Photoelectric Direct Reading Spectrometer

    TY-9610 - Wuxi Tianmu Instrument Technology Co., Ltd.

    1, Optical SystemStructure: Pa type - RungeRaster: Radius of curvature: 750mmIncident slit width: 20 μ mExit slit: high-precision photolithography of the entire slit, according to different elements set up 30u-75u slit width.Detector: Photomultiplier tube ( PMT ) detector2, all digital excitation light source1. Fully digital intelligent composite light source DDD technology, which can automatically adjust the excitation parameters of light source according to the excitation characteristics of different materials, and truly realize full digital control. 2. Using the all-digital control mode, high-energy pre-combustion technology ( HEPS ), ultra-stable energy release stimulates the sample in an argon atmosphere. 3. The application of all-digital light source improves the measurement accuracy and similarity of the sample, improves the sample excitation speed, improves the spark stability, and makes the sample have better reproducibility. The maximum discharge current reaches 400A .

  • Test Gas Generation Systems

    TU Series - HORIBA, Ltd.

    The test gas generation systems in the TU Series include a test gas generation system for evaluating the performance of various kinds of gas sensors, as well as systems for generating simulated gases for evaluating catalysts. These systems are personally tailored to customers’ intended uses.Among the systems we offer some utilise multiple mass flow controllers to mobilize functions (e.g. to generate gases of any concentration, to add moisture, to control supplied gas pressure and to heat gases) thereby allowing for comprehensive control via a PC or PLC.A common use of this product within the biotechnology field is as an atmosphere gas supply system inside fermenters.

  • Gas Analysis

    Dexter Research Center, Inc.

    Our infrared gas detectors provide superior sensitivity and reliability that may be translated into a more effective early warning system when monitoring atmospheres for gases at trace levels.  Our technology also offers the opportunity to perform sophisticated gas analysis.  One example: To assure personal safety during a medical procedure, our gas detectors deliver a precise monitoring of the ratio of exhaled gases of a hospital patient who is under general anesthesiology.  Another example, no canary need die in a mine if Dexter gas detectors are installed on the job.  Infrared lead detectors, whether mobile or mounted, can be a critical element in your health and safety strategy at home and on the job, whatever life forms it is your responsibility to protect.

  • Air Ion Detector

    DLY-71 - KILTER ELECTRONIC CO.,LTD

    The DLY's Air Ion counter is designed for measuring the concentration and the mobility of air ion. This instrument incorporates very high sensitivity. So,it can measure very low air ion level;for example, the background level of air ion in the atmosphere. The maximum measuring scale of them can reach up to 3.999~109 ions/cm3. These instruments are very effective to measure any types of artificial air ion generator or air purifier. Some model of these instruments can measure and display the positive and nagetive ions simultaneously. Some model of them can work in high humility area. Some model of them can automatically measure both positive and negative air ion concentration,record the test data and work out the variation curve of them by computer.The latest development of this instrument is DLY-71 air ion mobility spectrometer.It can measure large,medium and small air ion.It is very important to know the quality of the air by the concentration of them and the rate between large,medium and small ions.This instrument is one of the most important equipment to the people who work in the fields regarding science, medicine, environment protect, education, etc.

  • Circuit Card Assembly

    Teledyne Defense Electronics

    Teledyne Advanced Electronic Solutions assembles and tests a variety of complex circuit card assemblies (CCAs) using leading edge, advanced technology assembly automation. We specialize in low-volume, high-mix assembly of highly complex CCAs.- RF, analog, high-speed and digital circuits on rigid-flex and Cu core substrates- Typical lot sizes from 3 to 300 pieces- 4 high speed, flexible SMT lines- Production processes for components from 0201 chips to large grid-array components and connectors- 100% solder paste, automated optical, and x-ray inspection- Forced air convection reflow with inert atmosphere option- Special processes for RF assemblies (filters, shields, etc)- BGA underfill, conformal coating, etc.- Selective and wave solder pin-thru-hole processes- CCA and component bonding processes

  • Dynamic Gas Analyser

    ExQ - Hiden Analytical Ltd.

    The Hiden ExQ quantitative gas analyser is a new multi-featured and compact mass spectrometer system providing continuous on-line analysis of dynamic gas streams at pressures from sub-atmospheric up to 30 bar, the fully integrated system now being configurable both for benchtop and for rack-mounting operation. Connection to the process is via a flexible heated inert capillary line with a sample consumption rate less than 10 mL/minute and a response time of less than 300 milliseconds at pressures near atmosphere. The comprehensive range of process interface options enables adaptation of the system to accommodate analysis of up to 16 individual process streams, and adaptors are available for direct connection of the system to most standard TGA/TA instruments. External process data, sample temperature or mass for example, can be imported for combined integration and presentation with the mass spectral data.

  • Dual Shaker Testing

    National Technical Systems

    NTS has a number of facilities capable of conducting dual shaker testing, vibration testing utilizing multiple electrodynamic exciters, for the evaluation of large payloads.Once such example was conducted as part of the test program for NASA’s Lunar Atmosphere and Dust Environment Explorer or LADEE. NTS worked with NASA’s Ames Research Center for simulated environmental testing of the LADEE observatory which included dual shaker vibration.Vibration testing on the observatory was conducted utilizing the NTS Santa Clarita facilities tandem Ling B-340 electrodynamic exciters. These exciters allow either dual shaker vibration testing, or in the case of the LADEE observatory tests, they minimize the test set-up time. The electrodynamic exciters were staged with one in the thrust axis and the other set-up for lateral axes vibration. This dual shaker set up allowed for a quick transition from one test to the other. During the tests, the vibration test lab was maintained at a class 10,000 cleanliness level.

  • *High Current Switches

    B-1002 - Ruetz Technologies GmbH

    Ross High Current Switches are available up to 36,000 amps continuous and over 1,700,000 amps 20µsec RC pulse, with voltage ratings of 6 volts to 400kV peak test. Standard Ross high current switches are built with 80 to 120psi air cylinder actuators. Air cylinder or motor operated for high contact force.  Arcing contacts optional for closing current. G-10 epoxy glass laminate is standard insulation on most models. G-7 silicone glass is used on models available for RF applications above 100kHz.  Most Ross high current switches are available with additional lengths of insulation, where the high voltage contacts need to be spaced at a greater distance from the actuator and control circuit.  Voltage withstand value is at least doubled and the interrupt capability is much greater when high current switches are immersed in insulating oil, fluid or SF6 gas.  For gas atmosphere, no modifications are necessary; however, oil or fluid immersion requires modification at a slight extra cost.

  • High Current Switches

    B-1002 - ROSS ENGINEERING CORPORATION

    Ross High Current Switches are available up to 36,000 amps continuous and over 1,700,000 amps 20µsec RC pulse, with voltage ratings of 6 volts to 400kV peak test. Standard Ross high current switches are built with 80 to 120psi air cylinder actuators. Air cylinder or motor operated for high contact force.  Arcing contacts optional for closing current. G-10 epoxy glass laminate is standard insulation on most models. G-7 silicone glass is used on models available for RF applications above 100kHz.  Most Ross high current switches are available with additional lengths of insulation, where the high voltage contacts need to be spaced at a greater distance from the actuator and control circuit.  Voltage withstand value is at least doubled and the interrupt capability is much greater when high current switches are immersed in insulating oil, fluid or SF6 gas.  For gas atmosphere, no modifications are necessary; however, oil or fluid immersion requires modification at a slight extra cost.

  • Temperature Controlled Microscope Stage

    Linkham Scientific Instruments

    Specialists in temperature controlled microscopy, Linkam Scientific Instruments, announce the launch of their Optical DSC450 which enables simultaneous visualization of thermal processes for improved materials characterisation. The Optical DSC450 enables the user to measure glass transitions and melting behaviour of a wide range of substances whilst accurately controlling temperature from -196 °C to 450 °C. The atmosphere of the stage can also be purged with gas as required by the user. A new feature which will increase the characterisation capabilities of the DSC system is to combine it with imaging capability. The new LINK Digital Imaging module enables additional information to be obtained by correlating optical changes such as colour with temperature. The new TASC analysis tool takes this further. TASC (Thermal Analysis by Surface Characterisation) is a new image analysis capability which enables structural changes in samples to be tracked and quantified optically. It has the unique ability to measure local transition temperatures allowing different points on a sample to be identified. The new DSC system is great tool to use in research and quality control to measure quantitative values for glass transitions, melting peaks and sample purity and, when combined with TASC, even sample homogeneity.

  • HV Rotary Switches

    B-1003 - ROSS ENGINEERING CORPORATION

    A key feature of our rotary switches is their simple mechanical design which results in conservative stress levels for trouble-free, long life use.  In addition, each rotary switch has a reinforced chassis design utilizing G-10 or G-11 fire retardant anti-tracking coated epoxy glass insulation.  G-7 silicone glass is used for special applications where RF or high temperatures are involved.  Heavy duty contacts, specifically designed to minimize corona in the Ross rotaries, are made of highly conductive yet weld resistant alloy with high contact closing force.  This high force gives our rotary switches high momentary current capability and a reputation for their ability to withstand high shock and vibration as well as other severe environmental conditions.  Ratings to 150kV, to 200A.  When immersed in insulating oil, fluid or gas, the voltage withstand value is at least doubled and the interrupt capability is much greater.  In a gas atmosphere, no modification is required. However, immersion in oil or fluid may require modification in some cases, at an extra cost (optional).  Each unit is either manually or electrically operated.  One SPDT contact is standard on most units.  The auxiliary contact is used as an interlock for protection against "Switching Hot".