Filter Results By:

Products

Applications

Manufacturers

Atmosphere

1) a planet's exosphere, surface to space, space. 2) a unit of atmospheric pressure.

See Also: Atmospheric, Air, Earth, Climate, Space


Showing results: 76 - 90 of 101 items found.

  • Gas Detection Controller

    MX 43 - Teledyne Gas & Flame Detection

    Fully scalable, and designed to functional safety performance level 1 standa​rds, the MX 43 is an analog and digital controller that continuously measures and controls gases in the atmosphere. The MX 43 gas detector manages both digital lines and analog channels, and covers all needs for a wide variety of gas monitoring applications. The MX 43 digital technology allows up to 32 detectors to be distributed on 8 lines for increased cost savings.

  • Meter Test Switches

    The Eastern Specialty Company

    TESCO introduced the original Meter Test Switch in the early 1920’s. Today, TESCO’s line of Test Switches has been redesigned with the intention to combine the best features of tried and proven switching methods with improvements in materials and construction. All of the current carrying parts are bright tin plated to prevent corrosion. Good operating contact is assured on periodic meter tests, even when the switch has been idle for long periods of time in an unfavorable atmosphere.

  • CO2 Incubator

    INCOmed - Memmert GmbH + Co.KG

    Especially for in-vitro fertilization, the precision and reliability of the CO2 incubator are of crucial importance, as the slightest deviation in the CO2 atmosphere, temperature or humidity content during cultivation can already affect cell development. For this reason, Memmert has subjected its CO2 incubator INCOmed to a comprehensive evaluation process for its recognition as a medical device. The classification as class IIa medical device confirms that each Memmert CO2 incubator INCOmed complies with the essential safety requirements of the European Medical Devices Directive 93/42/EEC.

  • EU (European) Directive Testing

    F-Squared Laboratories

    F2 Labs provides expert evaluation, testing, and (where required) Notified Body services for the following EU Directives:*Radio Equipment Directive 2014/53/EU (RED), formerly R&TTE Directive*Electromagnetic Compatibility (EMC) Directive 2014/30/EU*Equipment for Explosive Atmospheres (ATEX) Directive 2014/34/EU*General Product Safety Directive 2001/95/EC*Low Voltage Directive 2014/35/EU*Machinery Directive 2006/42/EC*Medical Device Directive 93/42/EEC

  • Reservoir Isolators

    Parker Hannifin Corp.

    Fluid contamination can lead to high maintenance costs and downtime in hydraulic systems. Parker reservoir isolators provide protection against the ingestion of airborne contaminants such as dust, chemicals and water vapor through the breather-vent of your hydraulic system. Utilizing an elastomer bladder as a lung, the changes in gas volume in a hydraulic system's reservoir can be trapped and prevented from mixing with the outside atmosphere. Unlike conventional breather-vent filters, Parker reservoir isolators provide a positive separation without the possibility of clogging or need for maintenance.

  • Electrostatic Potential Monitoring Device

    Kasuga Denki, Inc.

    electrostatic potential monitoring device that has an interface for connecting our potential sensors EMS-01 / EMS-01A / KS-2100 and measures static electricity in real time. It is possible to monitor static electricity with simple  The compatible potential sensor EMS-01 / EMS . With SD card support, measurement data and alarm history can be collected with a time stamp. Operation using the touch panel display and screen display, and to notify and manage the measurement status with multiple control outputs. ...-01A Has Passed The Intrinsically Safe Explosion-Proof Structure Certification In Combination With The Safety Cage KS-301A, And Can Be Used In A Dangerous Atmosphere.

  • Vacuum Measurement

    Agilent Technologies

    Agilent's full range of active and passive vacuum gauges and gauge controllers from atmosphere to UHV/XHV allow you to precisely and reliably control and measure vacuum. We offer Thermocouple (TC), Bayard Alpert (BA), Pirani, Inverted Magnetron (IMG), and Hot Filament (HFIG) gauges. Our gauge controllers are compatible with both Agilent and competitors' gauges and can handle up to 12 channels. Agilent controllers come with several communication interfaces including Profibus, ethernet, and RS-232/485 (other interfaces may be available upon request). There is also the option of a portable gauge controller (HGC-536).

  • Open Path Combustible Gas Detector

    SafEye (Quasar 900) - Teledyne Gas & Flame Detection

    The Open Path Combustible system detects hydrocarbon gases by analyzing the absorption of radiation caused by gases in the atmosphere and comparing it to background atmospheric absorption. This is accomplished between a pair of units: a Flash Source and a Detector that can monitor a distance of up to 200 meters.Open Path Combustible Gas Detectors are robustly designed and can handle the toughest environments: 316L stainless steel housings that meet IP66/IP68 and NEMA 250 6P egress standards; circuit boards epoxy coated for protection; MIL-C-810C testing for humidity, salt, fog, vibration, mechanical shock and temperature extremes; and SIL-2 approval per IEC61508 is a final statement in reliability.

  • Gas Density Monitors

    WIKA Alexander Wiegand SE & Co. KG

    Sulfur hexafluoride (SF6) is an extremely effective electrical insulator for medium- and high-voltage switchgear. For proper insulation, gas density must remain within certain levels. Furthermore, as SF6 is a potent greenhouse gas, it must not escape into the atmosphere. An SF6 gas density monitor warns operators of dropping levels that indicate contamination and/or leaks. WIKA’s SF6 gas density monitors are temperature compensated and hermetically sealed to shield measurements from atmospheric pressure fluctuations and differences in mounting level. Manufactured entirely from stainless steel for reliability and long life, they are fitted with up to three alarm contacts to provide advance warnings when pre-defined limit levels are reached.

  • Altitude Simulation

    MEDAS - HORIBA, Ltd.

    The MEDAS system is a compact altitude simulator that reproduces a wide range of environmental conditions. It allows for testing light- to heavy-duty vehicles, including Non-Road Mobile Machinery (NRMM). It is ideally suited for a range of testing applications, such as durability, RDE replication, emission tests and mapping as well as tests from component to vehicle level. The patented technology inside the MEDAS system allows dynamic changes on the simulated atmosphere with high accuracy. The system can also be moved between different test cells due to its compact design.

  • Chemiluminescence 03 Analyzer

    Model T265 - Teledyne Advanced Pollution Instrumentation

    The Model T265 is the only commercially available US EPA Federal Reference Method for Ambient Ozone Monitoring according to the latest US EPA regulatory rules for O3. The instrument uses Chemilumescence with Nitric Oxide (NO) as a reagent, making is safe, stable, and effective for all applications. The NO-CL method for Ozone has several advantages over the conventional UV absorption technology, including the avoidance of positive and commonly found interferrents such as VOCs, fine particulates, Mercury, turpines, ClO2, and others. If these pollutants are present in the atmosphere, it can cause UV absorption analyzers to give an artificially high Ozone measurement. The innovative T265 combines speed of response, sensitivity and stability of our proven nitrogen oxide analyzer, with a simple user interface, to provide reliable ozone measurements under the harshest conditions.

  • Ozone Aging Test Chambers

    Dongguan Amade Instruments Technology Co., Ltd

    Ozone aging test chamber is also called as ozone climate simulator or ozone aging tester. It is one of climatic testing instruments, which is to simulate and intensify the ozone condition for determining the cracking resistance of vulcanized or thermoplastic rubbers when subjected to dynamic or static tensile strain exposed at a man-made constant temperature to atmosphere containing given concentration of ozone in conformance with relevant specification. Ozone test is an indispensable method for people to research effects and mechanisms of ozone on rubbers, quick identify and evaluate anti-aging performance of rubbers and find solutions for improvement of quality and lifespan.

  • Real-time and Direct Correlative Nanoscopy

    LabRAM Soleil Nano - HORIBA, Ltd.

    Fully integrated system based on our OmegaScope scanning probe microscope and LabRAM Soleil Raman microscope. LabRAM Soleil Nano offers unprecedented capabilities for direct co-localized AFM-Raman and photoluminescence measurements. AFM imaging modes (topographic, electrical, mechanical, etc.) and Raman acquisition can be performed either sequentially or simultaneously at the same location of the sample surface. Optical nano-resolution is also achievable with Tip-Enhanced Raman Spectroscopy and Photoluminescence (TERS/ TEPL). LabRAM Soleil Nano is compatible with the environmental chamber for AFM and Raman measurements in controlled atmosphere and at low temperatures.

  • Control Unit

    MX 256 - Teledyne Gas & Flame Detection

    The MX 256 is a digital control unit intended for the detection and measurement of gases present in the atmosphere and more generally for the processing of any digital signal from digital sensors (OLCT 10N types), relay module, analog output module, logic input module. Thanks to its new option, an industrial controller module or remote HMI, it is possible to add analog input modules for sensor-transmitter connection (4-20 mA) and / or relay modules, this allows to not only extend the capacities but also to have event recordings (Location, Alarms,.....) and to have access to the data via the embedded web page.

  • Salt Fog Chambers

    SCCH - Singleton Corp.

    Seamless, oven-cured vinyl lining for maximum service life and corrosion resistanceClear acrylic cover optimizes test observation.Individual temperature display for Dry Bulb, Wet bulb and Humidifying tower.Internally-baffled Opti-fog® tower for uniform atmosphere and efficient solution usage.Air Flow Meter - Convenient indication of Opti-fog® performance without waiting hours for collection rates.Level-Matic® Reservoir Assembly Automatically maintains proper solution levels to Opti-fog® and Humidifying Tower.Standard operating temperature of ambient to 120°F/49°C (higher temps optional)Fully tested and certified prior to shipment.

Get Help