Filter Results By:

Products

Applications

Manufacturers

Analyzers

examine data methodically by separating into parts and studying their interrelations. AKA: Analysers

See Also: Analyze, Analytics, Analysis


Showing product results. 1711 - 1725 of 3938 products found.

  • Guardian Electrical Safety Analyzer

    19032 - Chroma Systems Solutions, Inc.

    Electrical safety testing is a major item in electrical product quality testing. All electrical products like adapters, SMPS, charges, house appliances, information technology products, and video products are required to undergo electrical safety testing. The 19032 series combines Hipot, Insulation Resistance (IR), Ground Bond (GB), Leakage Current (LC)/AC LC/DC LC and Dynamic Function Tests. Space savings can be up to 50% of production line space, through not purchasing multiple safety test instruments. The 19032 is able to increase the efficiency of electrical safety testing during manufacturing and reduce associated labor costs.

  • Water Treatment Plant Analyzer

    HORIBA, Ltd.

    Aqualog® is the only instrument to simultaneously measure both absorbance spectra and fluorescence Excitation-Emission Matrices. EEMs are acquired up to a 100 times faster than with other instruments. Dedicated software automates traceable Quinine Sulfate Unit calibration and correction of inner-filter effects and Rayleigh and Raman scattering lines, enabling rapid export to modeling algorithms like PARAFAC.

  • Water Treatment Plant Analyzer

    Aqualog - HORIBA, Ltd.

    Aqualog® is the only instrument to simultaneously measure both absorbance spectra and fluorescence Excitation-Emission Matrices. EEMs are acquired up to a 100 times faster than with other instruments. Dedicated software automates traceable Quinine Sulfate Unit calibration and correction of inner-filter effects and Rayleigh and Raman scattering lines, enabling rapid export to modeling algorithms like PARAFAC.

  • Heated Type NOx Analyzer

    MEXA-1170HCLD - HORIBA, Ltd.

    The MEXA-1170HCLD is available as an atmospheric (A) and a vacuum (V) model. With nine ranges available from 10 ppm up to 10,000ppm, these instruments are designed to fit most applications in the industry.

  • Air-to-Fuel Ratio Analyzer

    MEXA-730λ - HORIBA, Ltd.

    Previously MEXA-700λII used know-how and ingenuity gathered from HORIBA air-to-fuel ratio measurement technologies used worldwide, to provide the highest level of performance.The MEXA-730λ adopts this performance and adds original design for enhanced visibility and operation.A new sensor coefficient data memory function makes it possible to restore back-up data, providing faster start-up times and saving valuable operation time.This enhanced device will meet your multiple testing requirements covering applications from, lab analysis of air-to-fuel ratio, excess air ratio and oxygen concentration, to on-board real time measurement.

  • Motor Exhaust Gas Analyzer

    MEXA-1300R - HORIBA, Ltd.

    MEXA-1300R is a motor exhaust gas analyzing system for two and four stroke engine assembly lines and has an integrated sample handling system for removal of oil and moisture. The measurement of CO, CO2, HC and O2 (optional) in exhaust gases is made simply by inserting the sample probe into the tail pipe. AFR and Lambda are also calculated from the exhaust gas concentrations.

  • Heated Type THC Analyzer

    MEXA-1170HFID - HORIBA, Ltd.

    With 14 selectable ranges - from 0-10 ppmC to 0-200,000 ppmC - MEXA-1170HFID can measure direct, CVS/tunnel-diluted, and evaporative-emission samples.A ten-key control pad and a color LCD make it easy to monitor the test data. Data transfer to a remote computer is possible via RS-232 or an optional analog output.

  • Motor Exhaust Gas Analyzer

    MEXA-ONE - HORIBA, Ltd.

    MEXA-ONE offers an intuitive user interface with a highly efficient hardware and software design.This results in increased testing efficiency and economical facility operation, while enhancing reliability and accuracy. These advancements are possible because the MEXA-ONE software employs new "HORIBA ONE PLATFORM". This platform integrates the test devices in an emission cell into a single user interface, increasing efficiency and optimizing user control over the entire testing process.

  • 2-Port 18 GHz Analyzer

    M5180 - Copper Mountain Technologies

    VNAs and ACMs are delivered with factory calibration certificates containing no data. The add-on option for ISO17025/Z540-1 Accredited, Traceable Calibration Certificate and Uncertainties is available and needs to be specified at time of order.

  • 2-Port 6.5 GHz Analyzer

    M5065 - Copper Mountain Technologies

    VNAs and ACMs are delivered with factory calibration certificates containing no data. The add-on option for ISO17025/Z540-1 Accredited, Traceable Calibration Certificate and Uncertainties is available and needs to be specified at time of order.

  • 2-Port 8.5 GHz Analyzer

    M5090 - Copper Mountain Technologies

    VNAs and ACMs are delivered with factory calibration certificates containing no data. The add-on option for ISO17025/Z540-1 Accredited, Traceable Calibration Certificate and Uncertainties is available and needs to be specified at time of order.

  • 34-Channel Portable Logic Analyzer

    16861A - Keysight Technologies

    34 channels, 350 MHz state, 12.5 GHz timing zoom, 2.5 GHz timing, 2 Mb depth standard15-inch (38.1 cm) color, touch-screen display for viewing and quickly navigating large numbers of signals and buses Built-in removable SSD drive, USB 3.0 ports and LAN for fast data transfer and storage of large amounts of data1.4 GHz trigger sequencer to ensure high-speed events are captured

  • 3-Phase Power & Harmonics Analyzer

    PQ3350 - Extech Instruments Corporation

    Power measurements and analysis + datalogging of single and 3-phase/3-wire or 3-phase/4-wire systems (up to 52,428 single phase readings or 17,476 3-phase readings). Large backlighting LCD displays up to 35 parameters in one screen. Clamp-on True RMS power measurements with on-screen Harmonics display. Simultaneous display of Harmonics and Waveform. Display of Waveform with Peak Values (1024 samples/period). Analysis of Total Harmonic Distortion (THD-F). Maximum Demand (MDkW, MW, kVA, MVA) with programmable period. Adjustable CT ratio (1 to 600) and VT ratio (1 to 3000). Graphic Phase diagram with 3-Phase system parameters. 3-phase Voltage or Current Unbalanced Ratio (VUR, VIR) and Unbalanced Factor (d0%, d2%). Calculated Unbalanced Current through Neutral Line (In). Capture 28 Transient events (including Dip, Swell and Outage) with programmable threshold (%). Optically isolated USB interface with software to download Waveforms, Power Parameters and Harmonics. Includes 4 voltage leads with alligator clips and retractable plunger clips, 8 AA batteries, universal AC adaptor, software, USB interface cable, and case. Current Probes sold separately.

  • 68-Channel Portable Logic Analyzer

    16862A - Keysight Technologies

    68 channels, 350 MHz state, 12.5 GHz timing zoom, 2.5 GHz timing, 2 Mb depth standard15-inch (38.1 cm) color, touch-screen display for viewing and quickly navigating large numbers of signals and buses Built-in removable SSD drive, USB 3.0 ports and LAN for fast data transfer and storage of large amounts of data1.4 GHz trigger sequencer to ensure high-speed events are captured

  • Advanced Low-Frequency Noise Analyzer

    E4727B - Keysight Technologies

    Get a deeper, closer look at low frequency noise with the A-LFNA integrated with WaferPro Express, featuring data analysis, wafer prober control and test suite automation.

Get Help