NEX XT - Applied Rigaku Technologies, Inc
Featuring third-generation X-ray transmission technology, the NEX XT represents the next evolution of process gauge for sulfur measurement (0.02% to 6% S) of crude, bunker fuel, fuel oils, and other highly viscous hydrocarbons, including residuums.The Rigaku NEX XT system is faster, more sensitive and far more compact than competitive systems, and provides continuous, reliable detection of sulfur at pressures up to 1480 psig. Rigaku NEX XT can operate as a stand-alone analyzer or provide real-time closed-loop control when tied into a blending or plant-wide automation system. Among its other key features are a simplified user interface, reduced standards requirement, automatic density compensation, password protection, and standard platform for communicating sulfur and density to a plant-wide DCS. Due to its unique design and robust construction, sample conditioning and recovery systems are typically not required.
-
CAT Standard Series - IBEKO Power AB
Circuit breakers are being tested during manufacturing, commissioning or maintenance stages. The most basic test requires timing measurement using circuit breaker timer. Their primary role is timing and motion measurement of medium and high voltage circuit breakers. Devices from CAT Standard series have suitable application in:electric power generation,distribution system,part of the electric power transmission system,contractors testing,and industrial environments.CAT Standard series meets the requirements of an easy to use circuit breaker timer and analyzer with an attractive price. Furthermore, they are portable and lightweight (weighs only up to 7 kg). Finally, the plastic case is unbreakable and has IP67 protective rating when the lid is closed.CAT Standard series includes five models:Three circuit breaker timers – CAT03, CAT31, and CAT61Two circuit breaker analyzers – CAT34 and CAT64CAT03 is a basic model intended only for timing measurement of main contact operations on the circuit breaker with one break per phase. Unlike CAT03, CAT31 has the possibility of circuit breaker operation initiation, coil current measurement, and auxiliary contact timing measurement. CAT61 differs in comparison to CAT31 by its ability to measure up to two breaks per phase.CAT34 and CAT64 are more advanced compared to CAT31 and CAT61, respectively, since they have additional analog channels. Also, they have the possibility of a travel curve recording.A user can download the test results to a USB memory stick or save it to internal memory. The CAT Standard series internal memory can store up to 500 test results (numerical and graphical data). Optional thermal printer prints test results in tabular and graphical form on 80 mm (3.15 inch) paper rolls. CAT Standard series instruments are compatible with DV-Win software. It provides full control of all CAT functions from a PC, as well as acquisition and analysis of test results.
-
DDR4 - FuturePlus Systems
Provides logic analyzer like deep transaction Listing and Waveform captureCan store up to 1G of captured StatesContinuous, real time analysis, not post-processingEye Detector guarantees valid data acquisitionExtensive Triggering and Storage Qualification allows precise insightProtocol Violation Detector provides hundreds of simultaneous, real time tests to JEDEC specificationsMargin analysis shows where command timing fails and where it can be improvedThousands of counters for DDR4 analyze performance metrics real time, all the time, for all commands, total Clocks, by Rank also power management informationInteractions among up to 8 ranks, over two slots are analyzed.Mode register and SPD capture are providedSupports Auto-Clock rate detect and clock stoppageConnects to the target under test with DIMM, SO-DIMM, and BGA interposers or a midbus probeIntegrated Microsoft Charts gives quick insight into large trace capturesTrigger In & Out allows the Detective to integrate with other test tools
-
CAT Advanced Series - IBEKO Power AB
DV Power circuit breaker analyzer and timer utilizes the latest technological enhancements for safe and fast testing of circuit breakers. The sophisticated design ensures efficient and reliable operations in high-voltage substations and industrial environments.The CAT Advanced series are stand-alone or PC-controlled digital instruments for a circuit breaker testing. The timing channels record closing and an opening of the arcing, resistor, and auxiliary contacts. Also, the main contact channels can measure the resistance value of the pre-insertion resistors (if present in the circuit breaker).With CAT Advanced series instruments, it is possible to record graphs of open and close coil currents. Furthermore, it records displacements of the HV and MV circuit breaker moving parts. Test results can be saved via USB, PC or be printed via 112 mm (4.4 inches) thermal printer (optional accessory) in tabular and graphical form.A circuit breaker test consists of different operational modes and CAT Advanced series supports:Open (O)Close (C)Reclose (O-0,3s-C)Trip free (CO)O-0,3s-COOpen-Close (O-C)Close-Open (C-O)Open-Close-Open (O-C-O)First trip (O)Multiple operations, such as Open-Close and Open-Close-Open, can be initiated by using a predefined delay time or by sensing a breaker’s contact position.The auxiliary inputs are used to monitor dry and wet auxiliary contacts. The six coil control analog channels measure and record coil currents simultaneously (OPEN and CLOSE), up to 35 A AC/DC.The additional six voltage analog channels have four selectable voltage ranges available (±1 V, ±5 V, ±60 V and ±300 V AC/DC).A built-in micro-ohmmeter generates up to 500A true DC ripple-free current with an automatically regulated test ramp that provides performing static and dynamic contact resistance measurement.Three transducer channels provide a measuring displacement of the circuit breaker moving parts, contact wipe, over-travel, rebound, damping time and average velocity. Also, a user can connect either an analog or a digital transducer to these universal channels.
-
CIS100 - Stanford Research Systems, Inc.
With better than 1 ppm detection limit, direct sampling at mTorr pressure, and a user-friendly Windows software package, the CIS systems will satisfy your most demanding applications. On-line process monitoring and control, verification of process gas purity at the point of use, high-vacuum residual gas analysis, and process equipment leak checking are some of the areas where these systems will prove indispensable
-
CIS300 - Stanford Research Systems, Inc.
With better than 1 ppm detection limit, direct sampling at mTorr pressure, and a user-friendly Windows software package, the CIS systems will satisfy your most demanding applications. On-line process monitoring and control, verification of process gas purity at the point of use, high-vacuum residual gas analysis, and process equipment leak checking are some of the areas where these systems will prove indispensable
-
CIS200 - Stanford Research Systems, Inc.
With better than 1 ppm detection limit, direct sampling at mTorr pressure, and a user-friendly Windows software package, the CIS systems will satisfy your most demanding applications. On-line process monitoring and control, verification of process gas purity at the point of use, high-vacuum residual gas analysis, and process equipment leak checking are some of the areas where these systems will prove indispensable
-
16863A - Keysight Technologies
102 channels, 350 MHz state, 12.5 GHz timing zoom, 2.5 GHz timing, 2 Mb depth standard15-inch (38.1 cm) color, touch-screen display for viewing and quickly navigating large numbers of signals and buses Built-in removable SSD drive, USB 3.0 ports and LAN for fast data transfer and storage of large amounts of data1.4 GHz trigger sequencer to ensure high-speed events are captured
-
16864A - Keysight Technologies
136 channels, 350 MHz state, 12.5 GHz timing zoom, 2.5 GHz timing, 2 Mb depth standard15-inch (38.1 cm) color, touch-screen display for viewing and quickly navigating large numbers of signals and busesBuilt-in removable SSD drive, USB 3.0 ports and LAN for fast data transfer and storage of large amounts of data1.4 GHz trigger sequencer to ensure high-speed events are captured
-
M5180 - Copper Mountain Technologies
VNAs and ACMs are delivered with factory calibration certificates containing no data. The add-on option for ISO17025/Z540-1 Accredited, Traceable Calibration Certificate and Uncertainties is available and needs to be specified at time of order.
-
M5065 - Copper Mountain Technologies
VNAs and ACMs are delivered with factory calibration certificates containing no data. The add-on option for ISO17025/Z540-1 Accredited, Traceable Calibration Certificate and Uncertainties is available and needs to be specified at time of order.
-
M5090 - Copper Mountain Technologies
VNAs and ACMs are delivered with factory calibration certificates containing no data. The add-on option for ISO17025/Z540-1 Accredited, Traceable Calibration Certificate and Uncertainties is available and needs to be specified at time of order.
-
16861A - Keysight Technologies
34 channels, 350 MHz state, 12.5 GHz timing zoom, 2.5 GHz timing, 2 Mb depth standard15-inch (38.1 cm) color, touch-screen display for viewing and quickly navigating large numbers of signals and buses Built-in removable SSD drive, USB 3.0 ports and LAN for fast data transfer and storage of large amounts of data1.4 GHz trigger sequencer to ensure high-speed events are captured
-
PQ3350 - Extech Instruments Corporation
Power measurements and analysis + datalogging of single and 3-phase/3-wire or 3-phase/4-wire systems (up to 52,428 single phase readings or 17,476 3-phase readings). Large backlighting LCD displays up to 35 parameters in one screen. Clamp-on True RMS power measurements with on-screen Harmonics display. Simultaneous display of Harmonics and Waveform. Display of Waveform with Peak Values (1024 samples/period). Analysis of Total Harmonic Distortion (THD-F). Maximum Demand (MDkW, MW, kVA, MVA) with programmable period. Adjustable CT ratio (1 to 600) and VT ratio (1 to 3000). Graphic Phase diagram with 3-Phase system parameters. 3-phase Voltage or Current Unbalanced Ratio (VUR, VIR) and Unbalanced Factor (d0%, d2%). Calculated Unbalanced Current through Neutral Line (In). Capture 28 Transient events (including Dip, Swell and Outage) with programmable threshold (%). Optically isolated USB interface with software to download Waveforms, Power Parameters and Harmonics. Includes 4 voltage leads with alligator clips and retractable plunger clips, 8 AA batteries, universal AC adaptor, software, USB interface cable, and case. Current Probes sold separately.
-
VP4000 - K-WILL Corp.
The The frame delay of 2160p full sample 4K reference video and 4K test video are compensated to fit exactly to each other by pixel base, and a real time objective quality score (DSCQS) are calculated by the ITU-T J.144-based assessing method in conjunction with the differential values (PSNR). This scheme is best suited to the encoder evaluation, online/standby comparison, inspection geared to video servers, and so on. For conventional 1080i image evaluation, a single PROBE4000 board can serve the purpose.