Filter Results By:

Products

Applications

Manufacturers

Analog Input Output

Analog I/O are Devices that have the capability of sending and receiving analog signals.


Showing results: 241 - 255 of 353 items found.

  • PXI-6115, 4 AI (12-Bit, 10 MS/s/ch), Buffer Size 32MS, 2 AO, 8 DIO, PXI Multifunction I/O Module

    778204-01 - NI

    4 AI (12-Bit, 10 MS/s/ch), 2 AO, 8 DIO, PXI Multifunction I/O Module - The PXI‑6115 is a simultaneous sampling, multifunction DAQ device. It offers analog I/O, digital I/O, two 24‑bit counters, and digital triggering. It is ideal for a variety of applications, such as stimulus/response applications where synchronization among analog input, analog output, and digital I/O is required, 42 V automotive applications, radar, sonar, and ultrasound. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.

  • Serial-to-Daq Minibox

    Model 2367 - ICS Electronics

    * 2367 provides 32 digital I/O lines, 4 analog outputs, 6 analog inputs, 6 relay driver outputs and 4 temperature inputs.* Firmware supports ASCII command strings, Addressed commands for RS-485 networks and packet protocol. * Operates as a RS-232 as a RS-485 to Data Acquisition Module. * DB-25 connector has both RS-232 and RS-485 signals.* SCPI commands and IEEE 488.2 compatibility provide GPIB like operation over the serial link. * The 2367 is packaged in a CE approved Minibox™ metal case to minimize EMI/RFI. * 1 U high Rack Mounting Kit mountsone or two 4867s.* Plug-on Terminal Board simplifies wiring connections.* Includes Universal Power Adapter and 62-pin mating connector.

  • 2 Channel ADC – High-Pin-Count

    ADCFN02 – HPC - Sundance Multiprocessor Technology Ltd.

    The RFM-ADCFN02 is a two channel Analog to Digital converter FMC which complies with VITA 57.1-2010. Each channel provides AC coupled single-end analog input and 16-bit single-ended output with 20-105MHz sampling speed based on ADI AD9650. Single-ended external clock, differential external clock or an internal clock from the FMC carrier board can be selected at the FMC for the AD converter through fine clock generator ADI AD9518-3.

  • PCI Bus Analog Output Board, 8 Isolated Outputs, 14 Bit

    APCI-3501-8 - TEAM SOLUTIONS, INC.

    *8 analog output channels*Optical isolation 500 V*Settling time 30 µs typ.*14-bit resolution (13 bit for 0-10 V)*Output voltage: ±10 V, 0-10 V (switchable through software)*Output voltage after reset: 0 V*Each output channel has its own ground line (without optical isolation from the others)*Driver capacity: 5 mA/500 pF*Short-circuit protection, EMI filters*Noise neutralization of the PC supply*Creeping distance: 3.2 mm acc. to DIN VDE 0411-100*Watchdog for resetting the analog output channels (4 different time units: µs, ms, s, min) or as 12-bit timer (with interrupt possibility), when the watchdog function is not necessary*2 digital input channels, 24 V, isolated*2 digital output channels, 24 V, isolated

  • Signal Spectrum Converters

    Advanced Science and Novel Technology, Co., Inc.

    DC to 5.6GHz finite impulse response filter.Two differential CML-type input ports and one differential CML-type output port.Nine analog tap-weight control inputs.Differential gain of approximately 0dB.Single +3.3V or -3.3V power supply.Power consumption: 422mW.Fabricated in SiGe for high performance, yield, and reliability.Custom CQFP 44-pin package.

  • Flow Computers

    Badger Meter

    Cox FC30 flow computers service both liquid and gas applications. The FC30 features batching, 40-point flow meter linearization tables, and temperature viscosity correction using Strouhal/Roshko advanced linearization methods and multiple flow and control inputs. Relay outputs are independently assignable for alarms and general purpose warnings. The FC30 has serial communications, both RS232 and 485, and isolated analog and pulse outputs.

  • Variable Reluctance Absolute Pressure Sensor

    AP10 - Validyne Engineering

    The AP10, Absolute Pressure Sensor, is designed for low and medium pressure measurements, to laboratory accuracy, of corrosive liquids and gases. In typical AC excited bridge circuits, this transducer delivers a full-scale output of 40 mV per volt at 3kHz. The unit operates with carrier systems including the Validyne CD15 sine wave carrier demodulator and CD16 miniature DC input DC output carrier demodulator to produce a high level analog DC output suitable for recording and control.

  • Control Unit

    MX 256 - Teledyne Gas & Flame Detection

    The MX 256 is a digital control unit intended for the detection and measurement of gases present in the atmosphere and more generally for the processing of any digital signal from digital sensors (OLCT 10N types), relay module, analog output module, logic input module. Thanks to its new option, an industrial controller module or remote HMI, it is possible to add analog input modules for sensor-transmitter connection (4-20 mA) and / or relay modules, this allows to not only extend the capacities but also to have event recordings (Location, Alarms,.....) and to have access to the data via the embedded web page.

  • 16 Channel USB Sensor Interface

    RogaDAQ16 - ROGA-Instruments

    With the introduction of the RogaDAQ16 USB 2.0 data acquisition system, a new age of measurement technology begins.*USB 2.0 / 480MBIT (USB1.1/12MBIT COMPATIBLE)*16 analog input channels (16bit/500kHz max.)*ICP ® ( IEPE ) sensor supply (24V/4mA)*0.125V to 10V input range*Individual preamplifiers*4 analog output channels (16bit/100kHz)*Powerful DSP (255MIPS) for filtering, control etc.*24 digital I/Os*Optional 24bit counter, timer, PWM, incremental encoder*Free drivers for major application software*including DASYLab; LabView & DiaDem drivers & RogaRec Software

  • Instrumentation Amplifiers

    Analog Devices Inc.

    Analog Devices instrumentation amplifiers (in-amps) are precision gain blocks that have a differential input and an output that may be differential or single-ended with respect to a reference terminal. These devices amplify the difference between two input signal voltages while rejecting any signals that are common to both inputs. The in-amps are widely used in many industrial, measurement, data acquisition, and medical applications where dc precision and gain accuracy must be maintained within a noisy environment, and where large common-mode signals (usually at the ac power line frequency) are present.

  • Multifunction I/O

    PXI-2206 - ADLINK Technology Inc.

    ADLINIK PXI-2204, PXI-2205, and PXI-2206 are high-density, high-performance multifunction PXI modules. These devices can sample up to 64 AI channels with various gain settings and scan sequences---making them ideal for high-density analog signals with various input ranges and sampling speeds. These devices also offer a differential mode for 32 AI channels to achieve maximum noise elimination. The PXI-2200 series also features analog and digital triggering, 2-CH 12-bit analog outputs with waveform generation capabilities, 24-CH programmable digital I/O lines, and 2-CH 16-bit general-purpose timers/counters.

  • 64-CH, 12/16-Bit, Up to 3 MS/s Multi-Function PXI Modules

    PXI-2200 Series - ADLINK Technology Inc.

    ADLINIK PXI-2204, PXI-2205, and PXI-2206 are high-density, high-performance multifunction PXI modules. These devices can sample up to 64 AI channels with various gain settings and scan sequences---making them ideal for high-density analog signals with various input ranges and sampling speeds. These devices also offer a differential mode for 32 AI channels to achieve maximum noise elimination. The PXI-2200 series also features analog and digital triggering, 2-CH 12-bit analog outputs with waveform generation capabilities, 24-CH programmable digital I/O lines, and 2-CH 16-bit general-purpose timers/counters.

  • 16-Channel VME RTD/Resistance Input Module

    V410 - Highland Technology, Inc.

    The V410 is a 6U VME module that provides sixteen independent analog inputs that may be used to read RTDs, thermistors, and other similar resistive sensors. It can also read cryogenic diodes. Users may set input range and adjust other settings at VMEbus speed, and depending on the range selected the microprocessor will do the necessary calculations and output voltage, resistance, or temperature. Temperature conversion is available for 100Ω and 1000Ω, series 385 and 392, platinum RTDs.

  • Series Voltage References

    Analog Devices Inc.

    Analog Devices offers a broad line of series voltage references with low dropout, low power, and excellent line regulation. These devices are voltage references that are functionally similar to a three-terminal regulator. Some series voltage references are designed to also operate in shunt mode by biasing the output pin and leaving the input pin open circuit. Series mode voltage references have the advantage that they draw only load and quiescent current from the input supply.

  • Modbus I/O extender

    CoolEx - Dimax

    CoolEx is a Modbus I/O extender with analog, digital and PWM inputs and outputs. CoolEx can be used in conjunction with Programmable Logic Controller (PLC) or any other Modbus master that requires some extra I/O or special I/O functionality. CoolEx is controlled by master by means of standard Modbus requests defined in "Modbus Application Protocol Specification".

Get Help