Filter Results By:

Products

Applications

Manufacturers

Acoustic Sources

Standard for calibrating sound level meters and sound measuring systems.

See Also: Sound Sources


Showing results: 16 - 30 of 30 items found.

  • CAD Tool

    Sabin - Acoustic Engineering

    Sabin is a powerful CAD tool for room acoustics engineers. Based on statistical calculations, it determines the acoustical parameters of a user defined room, such as the reverberation time T60, the sound pressure level, and the RASTI as a measure of speech intelligibility. These parameters are updated dynamically, while the user is changing simulated sound sources and absorbing materials.

  • Long Life Seismic Energy Source

    1500LL - Teledyne Marine Bolt

    Bolt introduced the LONG-LIFETM air gun in 1992. Since then it has become the standard energy source for marine seismic exploration. It is a stable, trouble-free energy source that produces high acoustic output. Another signature advantage is the long work life between required maintenance.The Long-LifeTM product line offers three models with different output volume ranges.

  • Signal Analysis

    Cross-Spectrum FFT Analysis - ZETLAB Company

    The program Cross narrow-band spectrum is used for evaluation of the interrelation between the signals’ parameters obtained from the two primary transducers installed at various parts of the controlled object. This program can be used for detection of noise source location, for sound absorption level evaluation and the researched object acoustic properties control, for evaluation of space-time distribution of the directional energy flux (Poynting vector), for the ground cross-section FR characteristic evaluation (Nakamura method), etc.

  • Swept Frequency Source - Acoustic Tomography

    Teledyne Marine Webb Research

    New acoustic projector design capable of swept-frequency output under digital control. Available as an integrated package including projector, signal generator, amplifier, microprocessor controller, and batteries. Available as a transceiver modification, which integrated with 4-channel acoustic STAR receiver (SCRIPPS), included a hybrid Rubidium low consumption clock and underwater acoustic navigation.

  • Partial Discharge Testing Equipment

    AR700 - Scope T&M Pvt, Ltd.

    PD Defect Location in High-Voltage Equipment Insulation by Acoustic Sensors To act on deteriorating insulation the source of PD must be known.The insulation defects produce partial discharges, which emits electrical impulses, radiation of electromagnetic waves as well as acoustic signals.The AR700 measures acoustic signals with multiple sensors spread over the transformer. Then the software determines the failure location using the time difference of all incoming signals. Finally, these coordinates are shown in a 3D model of the transformer. AR700 device is used for measuring of acoustic signals on the external surfaces of gas-insulated breakers and substations, power transformers and other tank high-voltage equipment. The acoustic signals are caused by partial discharges in the insulation, which is the sigh of the defects.The advantage of “AR700” device is the quick installation of the acoustic PD sensors on the external surface of high-voltage equipment tank. The sensors have magnetic holder that is why there is no need to de-energize the equipment for the sensors installation. “AR700” device has 4 syn-chronic channels for acoustic signal measurement. This gives the possibility not only to find the defects in the insulation, but also to locate them. The location function of the “AR700”device is unique for acoustic devices.

  • Phantom Powered Measurement Microphone System

    7052PH - ACO Pacific, Inc.

    The 7052PH Type 1.5TM phantom powered measurement microphone system offers a cost effective solution to acoustic measurements from phantom powered sources. Type 1.5TM - a superior Type 2. Frequency Response: <3 Hz to > 20kHz typ.(capsule). Sensitivity: 22 mV/Pa (-33 dBV/Pa)typ. Dynamic Range (capsule) 1% THD: <20dBA-150dBSPL (Capsule).

  • Type 1 Phantom Powered Measurement Microphone

    MK224PH - ACO Pacific, Inc.

    The MK224PH Type 1 phantom powered measurement microphone system offers a cost effective solution to acoustic measurements from phantom powered sources. Frequency Response: +/-2dB (8 Hz to 18kHz). Sensitivity: 50 mV/Pa (-26 dBV/Pa)typ. Dynamic Range 3% THD: 14dBA-145dB.

  • Multi-frequency Ultrasound And Acoustic Imaging Camera

    SonaVuTM - SDT Ultrasound Solutions

    SonaVu™ is an acoustic imaging camera. Using its 112 ultrasound sensors and optical camera, it can detect sources of airborne ultrasound and transmit them into a visual image on its touch screen. Defects such as compressed air system leaks, compressed gas system leaks, vacuum leaks, the presence of partial discharge on electrical assets, and failed/working steam traps all create turbulence. And when there is turbulent flow present, there is airborne ultrasound. SonaVu™ makes the superhuman hearing capabilities of SDT Ultrasound Devices visible to the human eye.

  • Sound Source Localization

    HEAD acoustics GmbH

    In order to optimize product sounds, it is necessary to know the exact point of origin of a sound source. This makes possible to identify the cause of disruptive sound components and rectify these effectively, optimize sound radiation and thereby achieve the desired sound experience. The ease of use and advanced beamforming algorithms of the HEAD VISOR acoustic camera allow sound sources to be located precisely at the blink of an eye.

  • 24-Bit High-Resolution Dynamic Signal Acquisition and Generation Module

    PCI-9527L - ADLINK Technology Inc.

    The PCI-9527L is a high-performance, 2-CH analog input and 2-CH analog output dynamic signal acquisition board. This board is specifically designed for audio testing, acoustic measurement, and vibration analysis applications.The ADLINK PCI-9527L features two 24-bit simultaneous sampling analog input channels. The 24-bit sigma-delta ADC provides a sampling rate up to 216 KS/s at high resolutions, making it ideal for higher bandwidth dynamic signal measurements. The sampling rate can be adjusted by setting the onboard DDS clock source to an appropriate frequency. All channels are sampled simultaneously and accept an input range from ±40 V to ±0.316 V. The PCI-9527L analog input supports software selectable AC or DC coupling and 4 mA bias current for integrated electronic piezoelectric (IEPE) sensors.

  • Power Measurement

    Precision Acoustics LTD

    Precision Acoustics manufactures Radiation Force Balances and Check Sources which can be used to measure ultrasound power according to the IEC Standard 61161. All products are supplied with a calibration from The National Physical Laboratory, LONDON.

  • Event Monitoring System

    Sigma 4 - Seismic Source Co.

    Sigma 4 utilizes the “Seismic Acoustic Monitoring” seismograph node. This is the most advanced, field-proven acquisition system in the world. It works seamlessly to provide the most fully integrated source control/recorder solution.*Autonomous Operation using Internal Storage*USB External Storage for Fast Data Collection*Use internal battery option or external power connection*Internal 3C geophone or external Geophone/Seismometer/Hydrophone/Microphone*Supports standard Ethernet equipment

  • Microphone Calibrators

    Trig-Tek™ 402H & 402PSI - Astronics Corporation

    Portable, self-contained, high-intensity acoustic microphone calibration source

  • Acoustic Emission Transducer

    GT301 - ZETLAB Company

    Acoustic emission transducer GT301 converts acoustic signal into electrical signal, parameters of which are used for acoustic emission source evaluation.

  • SGR Scintillation Gamma Radiameter

    GF Instruments, s.r.o.

    SGR scintillation gamma radiameter serves for fast and sensitive indication of gamma-ray sources. SGR covers two basic ranges of measurements:quick and selective searching for radioactive sources with fast response, acoustic signalization and histogram of 64 measured values radiometric measurements (dose rate) with the support of point and continuous measurements.

Get Help