-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1I-4
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 1.10 (31.00) - 3.85 (109.00)General Purpose Probe
SPA-64-4
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3: 0,365″; Tip 8: 0,385″; Tip ,9,10: 0,363″
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1I8-4-S
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
High Frequency LCR Meters Up To 30MHz
Chroma 11050
Chroma Systems Solutions, Inc.
Measurement capabilities cover the primary and secondary parameters required for testing the inductance, capacitance, resistance, quality factor and loss factor of passive components
-
product
Audio Frequency Output Power Meter
PGP Electronics Private Limited
PGP Electronics AF Output Power meter, model 3301provides reliable measurement of Audio Frequency Output Power. The audio power output meter, measurable from 0.01mW to 30W in 12 decades with 10 different termination impedances with both balanced and un balanced inputs. The instrument is very useful to conduct students projects, design and test simple sub systems in laboratories. New improved design features provides reliable working even in adverse environments.
-
product
Frequency Demultiplexer
Becker Nachrichtentechnik GmbH
Modern receivers for broadcast have a large number of antenna inputs for the different radio bands. The devices of the FDMX series can be used to supply the antenna inputs with RF signals. The devices of the FDMX series splits a sum signal in frequency division multiplex into the individual broadcast bands and the L1 satellite navigation band (GNSS). Additionally, DC loads are provided for each antenna input to simulate active antennas. The presence of remote power supply is indicated by an LED on the units.
-
product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4E
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
product
Full-Featured Open Source Free Implementation for the Object Management Group (OMG) Data Distribution Service for Real-Time Systems Standard
DDS Community
The DDS Community Edition is a full-featured open source, genuinely free implementation of the Object Management Group (OMG) Data Distribution Service for Real-Time Systems standard. Full-featured Apache license version 2.0 open source Data Distribution Service (DDS) implementation.
-
product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25I40-4
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3A
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
2-Port 9 GHz Analyzer, Frequency Extension Compatible
C4209
C4209 Vector Network Analyzer delivers industry-leading dynamic range and sweep speed, with all the features engineers have come to expect included standard in our software. This VNA is frequency extender compatible and is the anchor network analyzer for the CobaltFx frequency extender system.
-
product
Standard 0.70 (2.00) - 1.70 (4.80) General Purpose Probe
P2662AG-1R1S
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 710Overall Length (mm): 18.03
-
product
Standard 1.53 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-72T38-4
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
product
Frequency Dividers
SMA SPDT electro mechanical RF relay switch features Indicators, Failsafe, Normally Open with an isolation minimum of 60 dB. SPDT electromechanical relay radio frequency switch PE71S6052 is part of over 40,000 RF, microwave and millimeter wave components available from Pasternack. Our SPDT SMA coaxial RF relay electromechanical switch can ship worldwide the same day that it is bought as with our other available RF parts.
-
product
Multimeter Digital 1999 Counts Display with Holster with Capacitance Frequency
MY67
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
Multimeter digital 1999 counts display with holster with capacitance Frequency MY67 V&A.
-
product
Standard Voltage 37 Pin D-Type Connectors
The connectors below are not compatible with Pickering products, however, are offered for developing a connection solution for use with other products.
-
product
Digital Attenuator Operating Frequency of 1 to 20 GHz
LDA Series
The LDA series of Lab Brick® RF and Microwave Programmable Digital Attenuators includes 50 Ohm and 75 Ohm bidirectional RF step attenuators with calibrated operation up to 20 GHz. These USB powered and controlled units require no additional DC supply voltage. They are easily programmable for fixed attenuation or swept attenuation ramps directly from the included GUI. Lab Brick Digital Attenuator API DLL, Linux drivers and LabVIEW-compatible drivers are also available for custom programming applications.
-
product
Standard Mechanical Calibration Kit, DC To 3 GHz, Type-N, 75 Ohm
85036B
The Keysight 85036B calibration kit contains precision 75 ohm type-N standards used to calibrate Keysight network analyzers for measurement of devices with 75 ohm type-N connectors. Standards include fixed terminations, open circuits, and short circuits in both genders. This kit is specified from dc to 3 GHz.
-
product
Monolithic Balanced Mixers With Intermediate Frequency Amplifier
Insight Product Company offers Monolithic Balanced Mixers with and Intermediate Frequency Amplifier in frequency range of 26 to 178 GHz.
-
product
Standard- 27.20 (771.00) - 64.00 (1814.00) Godzilla High Current Probe
HC375F-4
Current Rating (Amps): 100Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 360Full Travel (mm): 9.14Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,110Overall Length (mm): 78.99
-
product
Standard Voltage 37 Pin D-Type Cables - Calibration Cables for Pickering
The cable assemblies below are suitable for use with Pickering precision resistor cards and modules that utilize 37-pin D-type calibration port connector.
-
product
Frequency Family 700 – 6000 MHz
A broadband amplifier that covers the 0.7 – 3.0 GHz frequency range. This small and lightweight amplifier utilizes Class A linear power devices that provide an excellent 3rd order intercept point, high gain, and a widedynamic range.
-
product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4J
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3G
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1F
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
product
Standard Gain Horn Antenna
SAS-586
This Standard Gain Horn Antenna will provide reliable, repeatable measurements. An ideal solution and a standard workhorse of any EMC test house for compliance testing. Features: 12.4 GHz to 18 GHz, Individually Calibrated, FCC, MIL-STD, VDE and TEMPEST Testing.
-
product
Standard Pattern Generator Board
BL-PG315-01
The MicroImage PG315 pattern generator is designed for simple size and geometry reference applications. The PG315 will overlay one of five standard patterns including a centered cross line, a centered cross hair, a centered target style symbol, a dot grid (cross dot) array, a hatch grid (crosshatch) array.
-
product
Multiparameter CTD with a Wide Choice of Standard Sensors.
MIDAS CTD+
Featuring Valeport’s latest 400 Series electronics, the CTD+ will sample all fitted sensors at exactly the same instant, at up to 8Hz. Advanced setup software allows a variety of sampling regimes including burst modes, delay starts and conditional sampling. Available with up to 64Mbyte memory and internal battery pack, as well as a selection of real-time output formats, the CTD+ may be used with Valeport’s own water bottle carousel.
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1Z1-4
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02





























