Decade Box, Calibrated W/Data, Capacitance, 5, 100pF to 11111µF, 5 %
72-7265 CAL D
-
The 72-7265 CAL D from Tenma is a capacitance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set at any non polarized capacitor value from 100pF to 11,111µF in 100pF increments. The decade accuracy is ±5% capacitors used throughout at <1μF, 1KHz test frequency, ≥1μF, 100Hz test frequency. It has weight of 304g/0.69lb and dimension is 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.
-
Product
RF Frontends
-
Becker Nachrichtentechnik GmbH
Software-Defined Radio (SDR) is an attractive approach for mobile communication architectures in the development and evaluation phase for a rapid prototyping on a flexible platform. SDRs support a wide frequency range. However, for practical use in the field the HF properties are insufficient. The transmit power is limited to a 2-digit mW value. Dedicated filters are required for an effective suppression of out-of-band signals and to improve the noise figure of the receiver chain. Extending SDRs with application-specific RF-frontends achieves optimal RF performance in the field.
-
Product
Film Tearing Strength Tester
DRK108C
-
Shandong Drick Instruments Co., Ltd.
DRK108C Tearing Tester is applicable in the tearing test of films, sheets, flexible PVC, PVDC, waterproof films, woven materials, polypropylene, polyester, paper, cardboard, textile and non-woven, etc.
-
Product
Strength Testing of Concrete, Brick and Mortar
Windsor Pin System
-
Measures the compressive strength of concrete, mortar and brick in-situ, quickly, accurately. A non-explosive instrument, the Windsor Pin System uses a spring-loaded device to drive a steel pin into the concrete or mortar.
-
Product
Octal 4 to 1 50 600MHz PXI RF Multiplexer
40-760-008
-
This octal 4 to 1 multiplexer is part of a range of RF multiplexers available in the following configurations: dual, quad and octal 4 to 1, single, dual and quad 8 to 1, single and dual 16 to 1 and single 32 to 1. All multiplexers have the option of automatic terminations which offer advantages at system level by reducing the presence of standing waves in the system which can cause degradation in isolation and crosstalk.
-
Product
PXI/PXIe RF Multiplexer, Dual 4-Channel, 3GHz, 50Ω, SMB
40-872A-002
-
The 40-872A-002 (PXI) and 42-872A-002 (PXIe) are 50 Ohm 4 to 1 PXI RF multiplexers with 2 banks in a single slot. They have low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss.
-
Product
High Precision Angular Positioning, Calibration and Geometry Inspection
LabStandard COMPACT
-
Rotary Precision Instruments UK Ltd
Designed for horizontal or vertical applications with a high accuracy angular encoder ensures sensitivity and fine positioning for metrology and precision testing.
-
Product
Heat Exchangers RF Coaxial Loads
86500 Series
-
The 86500 Series Heat Exchangers are ideal for areas where water is limited. The loads are rugged, self-contained, easily operated, and portable units capable of dissipating up to 80 kW of RF power from DC to 800 MHz with a VSWR of 1.10:1.
-
Product
Parallel Testing of Multiple DUTs with High RF Channel Count
Test Rack UTP 7033 RF for validation
-
Our basic test rack UTP 7033 (33 rack units) is intended for equipping with various products and therefore for various application areas.The rack shown here as an example is prepared with products and measurement instruments to test automotive devices with high channel count.
-
Product
PXI/PXIe RF Multiplexer, Dual 4-Channel, Terminated Common, 3GHz, 50Ω, MCX
42-876A-102
-
The 40-876A-102 (PXI) and 42-876A-102 (PXIe) are 50 Ohm 4 to 1 RF multiplexers with 2 banks in a single slot. Additionally, extra switching allows the common connection to be terminated into 50 Ohm, maintaining signal integrity. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
Product
Field Meter
AP 201 Plus
-
The AP201 Plus field meter with total coverage of terrestrial TV bands, cable TV (CATV), 1st IF satellite and, if the relative option is inserted, the return channel 5-65 MHz.
-
Product
Sound Level Calibrators
-
PeakTech Prüf- und Messtechnik GmbH
For sound level measurements in extreme conditions, at high altitudes or high demands on the accuracy of the measurement results, sound level meters should be checked prior to the measurement with a sound level calibrator. Also for calibration and verification of microphones in audio technology, you need a sound level calibrator, which is designed to produce several sound pressure levels at a fixed frequency characteristic. This calibrator has two switchable calibration steps.
-
Product
4-in-1 OSLT Calibration Kit, DC to 40 GHz, 2.92 mm (m)
CK562A
-
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
Product
PXI/PXIe RF Multiplexer, Single 16-Channel, Terminated, 8GHz, 50Ω, SMA
40-883B-002
-
The 40-883B-002 (PXI) and 42-883B-002 (PXIe) are single 16 to 1 50Ω RF multiplexers with 8GHz bandwidth and automatic termination of unused signal channels. They are available in 8 to 1 and 16 to 1 configurations in two and three slots respectively.
-
Product
Electrical Tester Grid Field
-
TCI can furnish grid spring probes for most Bare Board Electrical Testers in production at most Printed Circuit Board Manufactures. Look for your model of Bare Board Tester in the following list and call TCI for current price quotation.
-
Product
4-in-1 OSLT Calibration Kit, DC to 18 GHz, Type-N (m) 50 Ohm
CK518A
-
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
Product
MS-M Style 26-Pin RF Cable Assembly, Female To Unterminated, 1m, RG316 Cable
40-979-526-3-1m-FU
-
This 1m long MS-M style RF 26-Pin cable assembly is constructed from RG316 Silver Plated Copper Clad Steel Wire with PVC insulation and an attenuation of 68dB/100m at 500MHz. Screwlocks are provided to secure the MS-M style connector to the mating connector.
-
Product
GMCT 26-Pin RF Cable Assembly, 75Ω, Male To Unterminated, 0.5m, RG179 Cable
40-979-726-0.5m-FU
-
This 0.5m long cable assembly is part of a range of cables suitable for applications using the Positronic 26-pin GMCT 75Ω RF connector. It is constructed from RG179 silver plated copper clad steel cable with FEP insulation and a bandwidth of 500MHz. Screwlocks are provided to secure the connector to the associated product.
-
Product
PXI-2546, 2.7 GHz, 50 Ω, Dual 4x1 PXI RF Multiplexer Switch Module
778572-46
-
2.7 GHz, 50 Ω, Dual 4x1 PXI RF Multiplexer Switch Module—The PXI‑2546 is an RF signal multiplexer switch module. The multibank architecture of the PXI‑2546 makes it ideal for test systems that require parallel operations such as RF stimulus-response testing. The module also provides excellent insertion loss, voltage standing wave ratio (VSWR), and isolation parameters to minimize signal degradation. You can use the onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.
-
Product
Infrared Calibrators
-
Electronic Development Labs, Inc.
Designed to test, verify, and calibrate infrared thermometers, pyrometers, and thermal imagers for accuracy.
-
Product
PXI/PXIe RF Multiplexer, Dual 4-Channel, 3GHz, 75Ω, MCX
42-832A-102
-
The 40-832A-102 (PXI) and 42-832A-102 (PXIe) are 75 Ohm 4 to 1 RF multiplexers with 2 banks in a single slot. They have been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss.
-
Product
PXI High-Density RF Multiplexer: 3 GHz, 1 x 16, 50 Ω
M9149A
-
Route signals up to 3 GHz through a 1 x 16 RF switch multiplexer in a single PXI module.
-
Product
PXI 16x2 RF Matrix 300MHz 50 Multiway Connector
40-728-002
-
40-727/728/729 are RF Matrix Modules suitable for switching frequencies to 300MHz (50Ω version). The modules are available in either 50Ω or 75Ω versions with a choice of coaxial connectors. The 40-727/728/729 are designed designed to provide a simple and scalable bidirectional matrix to RF frequencies. They are intended for the easy construction of high performance bidirectional matrix switching systems.
-
Product
SP5T RF Pin Diode Switches To 12 GHz
-
Pulsar Microwave's 5-way RF switches cover bands from 300 MHz to 12 GHz in both absorptive and reflective configuration. These SP5T switches have a rating of 200 mW maximum input power and a switching time of 100 ns. They are specified with a minimum isolation of 60 dB and most models maintain a VSWR of 1.6:1 or better on all ports. The SP5T switches are driven by TTL logic control circuitry and require both positive and negative 5-volt supplies for operation. A 9-pin D-SUB connector provides the interface for the power and logic voltages.
-
Product
2 GHz Dual 1:4 RF Mux, 75 Ohm Module for 34970A/34972A
34906A
-
The Keysight 34906A RF multiplexer module for the 34970A/34972A Data Acquisition/Switch Unit offers broadband switching capabilities for high-frequency and pulsed signals. Use it to route test signals between your device under test and your signal generator, oscilloscope, spectrum analyzer, or other instrumentation. The RF multiplexers are arranged as two independent 1 x 4 multiplexers, each with a common shield and a switched center conductor. Connections can be made directly to SMB inputs with 2 GHz usable bandwidth, or to the BNC-to-SMB adapters provided with 1 bandwidth. Multiple banks may be cascaded together for applications requiring even larger topologies--create a stubless 16:1 multiplexer in a single frame.
-
Product
Selective RF Detector
Raksa iDet
-
RAKSA iDet detects: cellular phones of GSM900/1800, UMTS(3G), CDMA450 standards; cordless DECT phones; Bluetooth and Wi-Fi devices; wireless video cameras; radio transmitters with analog modulation (AM, FM, PM); radio transmitters with digital modulation and continuous carrier (FSK, PSK, etc.); radio transmitters with wideband modulation up to 10 MHz bandwidth.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 3.5 Mm, 2 Port
85093D
-
The Keysight 85093D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.