Product
Global Standard Model For 4 Point Probe Sheet Resistance Automatic Measurement System
RT-3000/RG-1000F
-
*Fully automatic system for large sizes of flat panel with glass loading robot*Tester self-test function, Measurement position correction function, wide measurement range*Min. 0.1 mm meas. resolution and user programmable test pattern*Host (CIM) communication and 2-D/3-D Mapping software
-
Product
PXI/PXIe RF Matrix, 16x2, 300 MHz, 50 Ω SMB
42-728A-001
Matrix Switch Module
The 40-728A-001 (PXI) and 42-728A-001 (PXIe) are 16x2 50 Ω RF matrices with SMB connectors. The 4x-727A/728A/729A range are high density RF matrix modules suitable for switching up to 300 MHz in 50 Ω or 100 MHz in 75 Ω. They are available in 50 Ω or 75 Ω versions with SMB connectors or in 50 Ω versions with a multiway connector. They provide a simple and scalable bidirectional matrix for RF signals and are intended for the construction of high performance switching systems.
-
Product
Suitable for Thermocouple Sensors Approved to ATEX and IECEx standards
TTC200X
-
Approved to ATEX and IECEx standards allowing for use in hazardous area applications.
-
Product
PXI/PXIe RF Multiplexer, Single 16-Channel, 3GHz, 75Ω, MCX
42-835A-101
Multiplexer Module
The 40-835A-101 (PXI) and 42-835A-101 (PXIe) are single 75 Ohm 16-channel RF multiplexers in a single slot. It has been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. The MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz. The design of the 40/42-835A minimizes the injection of noise and unwanted signals into the signal path by careful attention to the mechanical and electrical design.
-
Product
EMCTD Broadband RF Safety Systems
-
The EMCTD analog Smart Fieldmeter® is easy to read and to operate. The EMCTD broadband electromagnetic probe covers the 0.2 to 3000 MHz spectrum where most common industrial, communications, medical and government RF emitters are found. The ANGPE-3000 system enables checking of home, office, and workplace RF levels. The system is designed to conveniently measure RF levels around WiFi access points, RFID systems and rooftop antennas; to find transmitter cabinet radiation, locate transmission line leaks, to identify non-radiating antenna elements, and much more. With the supplied NIST-traceable calibration, this system supports laboratory testing of RF devices in compliance with present EMC and RF safety standards.
-
Product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1L
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
PXI/PXIe RF Matrix, 8x4, 300 MHz, 50 Ω SMB
40-729A-001
Matrix Switch Module
The 40-729A-001 (PXI) and 42-729A-001 (PXIe) are 8x4 50 Ω RF matrices with SMB connectors. The 4x-727A/728A/729A range are high density RF matrix modules suitable for switching up to 300 MHz in 50 Ω or 100 MHz in 75 Ω. They are available in 50 Ω or 75 Ω versions with SMB connectors or in 50 Ω versions with a multiway connector.
-
Product
Standard Voltage 37 Pin D-Type Cables - Connector to Connector for Pickering
-
The connector to connector cable assemblies below are suitable to use with Pickering cards and modules that utilize a standard voltage 37-pin D-type connector.
-
Product
Portable Microscope With XY Stage, X150 2mm Field Of View
-
*Veterinary Worm Egg Counting*Counting of algae and other samples*Easy positioning of the sample*Methodically scanning of slides and counting chambers*Works with standard microscope slides and counting chambers (25x75mm or 1”x2”) and with 32mm wide counting chambers*Allows manual movement of the slide and counting chamber independently in the left-right (X) axis and front-back (Y) axis
-
Product
DUAL RF Multiple-Input/Output
FMC-SDR400
-
Sundance Multiprocessor Technology Ltd.
FMC-SDR400 is a Dual RF multiple input/output module (MIMO) based on AD9361, 70MHz – 6GHz RF transceiver and AD9656 ADC for baseband sampling of less than 70MHz (input only in this range). A software selectable gain and tunable RF bandpass front-end section provides high RF sensitivity by allowing rejection of out-of-band-of-interest interfering signals.
-
Product
Closed-Link Field Test Kit
630
-
TESCO’s Closed-Link Field Test Kit (Catalog No. 630) with Power Factor has been designed to reduce the weight of field test equipment to the lowest possible limit when testing electric meters without potential links or with the links closed. The unit is protected within its ergonomic carrying case by a durable powder coated aluminum shell. The total weight of the meter test kit including leads, and digital reference standard is only 30 lbs! The test kit carrying case also incorporates ample storage space for the cable set and other tools.
-
Product
75 Ohm SMZ/Type 43 Cable Assembly
40-977-711-2m
RF Cable Assembly
Pickering Interfaces offer a range of RF cable assemblies to complement our extensive range of PXI, LXI, PCI, VXI and GPIB switching products. All cable assemblies are made from high quality materials and use best practice assembly methods to ensure the cabling matches the performance of the switching modules they support.
-
Product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4F
General Purpose Probe
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
Product
50 Ohm MMCX to MMCX Cable Assembly
40-977-571-2m
RF Cable Assembly
This 2m long MMCX cable assembly is part of the range of RF cables. Pickering Interfaces offer a range of RF cable assemblies to complement our extensive range of PXI, LXI, PCI, VXI and GPIB switching products. All cable assemblies are made from high quality materials and use best practice assembly methods to ensure the cabling matches the performance of the switching modules they support.
-
Product
Standard 1.53 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-72T38-4
ICT/FCT Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
RF Shielded Chamber
MIL-STD
-
A high performance RF-shielded chamber specifically designed for radiated emissions testing in accordance with MIL-STD-461E/F. This chamber can be used for conducted emissions, conducted immunity, radiated emissions, and radiated immunity testing.
-
Product
PXI/PXIe RF Matrix, 16x4, 300 MHz, 50 Ω, SMB
40-724-012
Matrix Switch Module
The 40-724-012 (PXI) and 42-724-012 (PXIe) are 16x4 RF matrix modules suitable for switching frequencies up to 300 MHz. Having a 50 Ω characteristic impedance and front panel SMB connectors, these modules provide a simple and scalable bidirectional matrix for RF and are intended for the easy construction of high performance switching systems.
-
Product
Ruggedized Field Deployable Tester
PUMA
-
- 18-slot PXI / 4-slot SCXI Chassis- 1.2 GHz Embedded Controller- 4-axis Motion Controller/Simulation- 8-port RS-232 Serial Module- 4-port RS-485 Serial Module- 48 bit Isolated Digital I/O- Reconfigurable multi-function I/O FPGA Module- 5 1/2 digit DMM- 200 MHz 2-channel Scope/Digitizer- Multi-function Data Acquisition (DAQ)- 8-channel Analog Input Module- 6-channel Analog Output Module- General Purpose Switching- RF suite (optional)
-
Product
PXI/PXIe RF Matrix, 16x4, 300 MHz, 50 Ω SMB With Loop-thru
40-727A-001-L
Matrix Switch Module
The 40-727A-001-L (PXI) and 42-727A-001-L (PXIe) are 16x4 50 Ω RF matrices with SMB connectors and Y-axis loop-thru. The 4x-727A/728A/729A range are high density RF matrix modules suitable for switching up to 300 MHz in 50 Ω or 100 MHz in 75 Ω. They are available in 50 Ω or 75 Ω versions with SMB connectors or in 50 Ω versions with a multiway connector.
-
Product
RF Cable Assemblies
-
Radiall's extensive range of RF cable assemblies features outstanding electrical performance, low loss and high frequency. The range includes flexible, semi-rigid, corrugated and hand-formable cable assemblies with a combination of RF cables and connectors optimized for each market or application. Custom RF cable assemblies are also available.
-
Product
2 GHz Dual 1:4 RF Mux, 50 Ohm Module for 34970A/34972A
34905A
Multiplexer Module
The Keysight 34905A RF multiplexer module for the 34970A/34972A Data Acquisition/Switch Unit offers broadband switching capabilities for high-frequency and pulsed signals. Use it to route test signals between your device under test and your signal generator, oscilloscope, spectrum analyzer, or other instrumentation.
-
Product
PXI/PXIe RF Matrix, 16x2, 300 MHz, 50 Ω SMB With Loop-thru
42-728A-001-L
Matrix Switch Module
The 40-728A-001-L (PXI) and 42-728A-001-L (PXIe) are 16x2 50 Ω RF matrices with SMB connectors and Y-axis loop-thru. The 4x-727A/728A/729A range are high density RF matrix modules suitable for switching up to 300 MHz in 50 Ω or 100 MHz in 75 Ω. They are available in 50 Ω or 75 Ω versions with SMB connectors or in 50 Ω versions with a multiway connector.
-
Product
MS-M Style RF Connector Female Contacts RG179
40-969-701-FC
RF Connector Female Contact
This is a 30 piece kit of RF Connector Female Contacts for MS-M style Connector Housing, suitable for RG179 Co-axial Cable.
-
Product
Standard 2.00 (57.00) - 3.60 (102.00) General Purpose Probe
P2664G-1C1S
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 10Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 114Full Travel (mm): 2.90Recommended Travel (mil): 84Recommended Travel (mm): 2.13Overall Length (mil): 895Overall Length (mm): 22.73Overall Length Remark: Tip 1C: 845 mil (21.46 mm) Tip 2R: 935 mil (23.75 mm)
-
Product
Coating thickness XRF Standards
-
We manufacture high accuracy reference standards capable of calibrating virtually any X-Ray Fluorescence (XRF) coating thickness and composition analysis system.
-
Product
RF Electronic Calibration Module (ECal), DC To 13.5 GHz, 4-ports
N4431D
-
The Keysight N4431D RF electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy and accurate. The N4431D is a precision 4-ports ECal module that supports multiple selection of connectors like Type-N, 3.5 mm, 7-16 and 4.3-10 connectors and can be mixed up to 13.5 GHz. Select either female-female, male-male, or female-male connectors.
-
Product
High-Power Directional RF Wattmeters
81100-A Series
-
The 81100-A series of High-Power Directional RF Wattmeters are designed to measure RF power in 50-Ohm 1-5/8 inch coaxial transmission lines. To use the Wattmeter, simply connect it between the transmitter and antenna or dummy load and plug in the appropriate measuring element.
-
Product
PXI Dual 4 to 1 RF Multiplexer 3GHz 50 Ohm SMB Terminated
40-876-002
Multiplexer Module
The 40-876-002 is a 50 Ohm 4 to 1 RF multiplexer with 2 banks in a single PXI slot. Additionally, extra switching allows the common connection to be terminated into 50 Ohm, maintaining signal integrity. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss. The injection of noise and unwanted signals into the signal paths of the 40-876 has been minimized by careful attention to the mechanical and electrical design.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 4.3-10, 2 Port
85094D
-
The Keysight 85094D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
PXI/PXIe RF Multiplexer, Quad 4-Channel, 3GHz, 50Ω, SMB
40-872A-004
Multiplexer Module
The 40-872A-004 (PXI) and 42-872A-004 (PXIe) are 50 Ohm 4 to 1 RF multiplexers available with 4 banks in a single PXI slot. They have low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss.