-
product
Current & Voltage Sources for Calibration of Measuring Systems and Sensors
ChenYang Technologies GmbH & Co. KG
*DC/AC Current: 0-60A *DC/AC voltage: 0-1000V frequency 50Hz, 60Hz, 400Hz, 1kHz
-
product
PXI/PXIe High Voltage Multiplexer, Quad 5-Channel, 1-Pole
40-321-101-HI
The 40-321-101-HI (PXI) and 42-321-101-HI (PXIe) are quad 5-channel 1-pole high voltage multiplexers capable of hot or cold switching up to 1000 V peak. They are also available in a range of bank sizes with 1 or 2 poles and channel counts between 4 and 48. High quality reed relays are used throughout.
-
product
Isolated Voltage Source
SIM928
Stanford Research Systems, Inc.
The SIM928 Isolated Voltage Source is ideal for applications where ultra-clean DC voltage is required. Voltage can be set between ±20 VDC with millivolt resolution, and the source can drive up to ±10 mA
-
product
IRIG-B TTL TO RS485 Converter
SPC - INS - 1010
Signals & Systems India Private Limited
The IRIG-B TTL signal is a time synchronization protocol that can be transmitted up to 50m maximum using coaxial cable. So the relay which is to be received the IRIG-B TTL signal may be far away from the IRIG-B source. The relay may be not able to synchronize with the GPS. To avoid such an incident in the field, some of the relays have provision to receive IRIG-B RS485 signal. The IRIG-B RS485 signal can able travel up to 1200m without any booster. All Time source equipment may not be supplied with IRIG-B RS485 signal output. The converter will act as a bridge between GPS Time source and Relays for time synchronization.
-
product
AC Voltage Proving Units
HLV-1
Standard Electric Works Co., Ltd
● Designed to proof. AC voltage detectors AC voltage testers● Compact, handheld, and easy to carry and use.● Battery operated.● LED indicates when power is "ON".● Normal 4mm test leads.
-
product
Safety Voltage Detector
305 SVD
Standard Electric Works Co., Ltd
Bright LED visual indication. Audible indication. AC voltage detection: 100Vac ~ 69kVac. Frequency range: 40 ~70Hz. Easy-to-prove method. Self-test function. Power source: 9V alkaline battery. Non-contact detection by proximity. Convenient to use. Operating temperature and humidity: 0°C~40°C / 80% RH Max. Lightweight, robust and compact. Easy access to battery. Comply with EN 61326-1
-
product
12 Pulse SCR Controlled High Voltage Power Supply
- 12 Pulse SCR Controlled Power Supply, P/N 19435PS- Input: 480 VAC, 300 Amps, 3 PH, 60 Hz- Output: 0 to 3000 VDC ± 10%, 80 Amps max adjustable with potentiometers, and 4/20 mA input signals from the PLC- Output voltage and current are provided as 4/20 mA signals to PLC- Contactor and overload relay are installed for protection- Power ON Light- Start / Stop capability- EPO capability- Manual voltage control and current limit- PLC interface- Output voltage and current are displayed on the voltmeter and ammeter.- A selector switch is used to select between manual Control or PLC Control- The customer is responsible for the PLC controller and PLC programming- Power enclosure, 68″H x 65″W x 44″D- Control enclosure: 20″H x 16″W x 9″D- Weight: 5000 lbs. approximately- All input/output connections are inside the enclosure
-
product
32-Ch High Voltage Relays & Multimeter
YAV90HVT
The YAV90HVT is used as an automatic CAN bus controlled floating AC/DC true RMS digital volts/milliamps meter with built-in scanner, able to work directly in appliances and industrial mains powered electric/electronic equipment.Its powerful microcontroller allows to work as a distributed device able to data acquire, compare and return high level messages, reducing test operation time.The analog output is used as a set value for the optional high voltage programmable power supply for Hipot tests up to 1500V.The board uses Tripaddle connection modules and can operate as stand alone or be mounted on a standard Virginia Panel receiver.The board includes National Instruments LabView virtual control panel and operating software for a true Plug & Play operation.
-
product
DC/DC Converter 100 W
CTS-120-6865-D
DC/DC converter with 100 W from Premium | input ranges 14.4 - 30 VDC | output 5 V | operates in temperatures from -25 to +85 °C | designed according to EN50155
-
product
Fuel Flow and Torque Converter
Model 44SM1
This self-contained, remotely mountable Second Harmonic Fuel Flow Interface accepts data from a second harmonic fuel flow transmitter then converts this information into a frequency output proportional to fuel flow. In addition, this module will accept signals from a T56 Torque Tranducer and provide a DC voltage proportional to Torque. Typical application is for use with Flight Management and Nav Management Systems. The use of field proven designs and carefully selected components assures high reliability field performance.
-
product
High Voltage Test System
CKT1175-15
12.5 mV – 2000 VDCIR measurements to 5000 megohmsHipot testingDwell time prog. from 1 ms to 1000s in 1 ms steps
-
product
Precision High Voltage Meter
Precision High Voltage Meter offers the highest level of measurement accuracy, yet with its color touch screen – is surprisingly easy to use. Vitrek leverages DSP technology to provide outstanding AC &DC voltage measurement accuracy, stability, repeatability and resolution. The 4700 High Voltage Meter offers performance that rivals traditional high voltage reference dividers – yet unlike the tedious divider, the 4700 provides instant, direct, high voltage measurements in a highly portable, compact and rugged bench top enclosure.
-
product
Standard Voltage 9 Pin D-Type Connectors for Pickering
The connectors below are suitable to use with Pickering cards and modules that utilize a standard voltage 9-pin D-type connector.
-
product
Selenium Voltage Doubler Rectifier P/N 6063C
Selenium Voltage Doubler Rectifier, P/N 6063CPlate size: 1.6” x 1.6”Each plate is rated for 33 Volts, 9 AmpsNumber of plates: 24
-
product
Signal Transporter E/O - O/E Converter pair
LTX-5515
The LTX-5515 enables the precise conveyance of one analog channel plus four digital channels of information over fibre optic links ranging from metres to more than 10 kilometres. Incoming analogue data is digitised to 12-bit precision at 100 megasamples per second and transmitted over optical fiber at one giga-bit per second.?
-
product
2kV, 120 MHz High Voltage Differential Probe with Auto Zero Disconnect
HVD3206A
The HVD3000A series of high voltage differential probes cover the fullest range of applications, from 120/240 V switch-mode power supplies through 600 V class and 5 kV electrical apparatus. The table below provides a list of recommended probe models based on specific device under test applications.
-
product
Portable Voltage and Current Instruments
Each model in our portable test equipment range is designed for accuracy and reliability, providing high performance and ease of use for applications. Products are used in various lab and field applications across industries such as research and development, semiconductor, and process control. For higher range electrical source and measure we have a series of bench multifunction calibrators and multimeters.
-
product
Vector And Scalar Mixer / Converter Measurements
S95083B
The Keysight S95083B measurement software includes the scalar mixer / converter plus phase (SMC+Phase) measurement class. It provides fully calibrated conversion gain / loss, relative phase, and absolute group delay measurements of mixers and converters without the need for reference or calibration mixers. Eliminating the calibration mixer requires a U9391C / F / G comb generator and an external DC power supply. A vector mixer characterization (VMC) is also included for measuring group delay of frequency-converting devices. VMC can be used to characterize a user-supplied calibration mixer.
-
product
Surge Voltage Generator
SSG 500
BAUR Prüf- und Messtechnik GmbH
Cable fault location with the BAUR SSG 500. The SSG 500 surge voltage generator is arranged in a 19'' housing. Maximum safety is achieved with the electrical safety control unit, the automatic discharge unit, the fully enclosed design and separate protection and system earth.* 6 output voltages up to max. 16 kV available* Electromagnetically actuated surge switch* Preselectable surge energy: 288 / 512 Ws (in all voltage ranges)* Automatic discharge unit
-
product
Clamping Voltage Tester
MIG0603CLV1
The MIG0603CLV1 is a generator for testing varistors. It has circuits with three different source impedances and up to 11 different measurement ranges. The instrument is used to perform varistor clamping voltage tests on up to 1000 V varistor types. The test impulse is a 8/20µs current waveform up to 200A which is maintained over the entire load range.
-
product
IEC61000-4-11 Voltage Dips And Interruptions Simulator Generator
VDS-1120DX
Shenzhen Chuangxin Instruments Co., Ltd.
The voltage dip and interruptions generator is specially designed according to the characteristics and requirements of EMS measurement under a sudden reduction or interruption of the voltage at a point, CSS61000-11/ CSS61000-11T used a big LCD in both English and Chinese operating interface. They have more fine performance such as high reliability, convenient operation, and full meet the standard requirements of IEC 61000-4-11, EN 61000-4-11 and GB/T17626.11
-
product
Analog-To-Digital Converters
Teledyne e2v has been innovating data converter technologies for over 20 years and offer a range of analog-to-digital converters that feature:Latency as low as 5 nsUp to 4 channels at microwave frequenciesLowest noise vs. performance on the market at microwave frequenciesThe cutting-edge technology packed into Teledyne e2v's data converters allow our customers to significantly simplify designs with licence free, standard and customized solutions.
-
product
DC/DC Converter 150 W
CQB150W-110S3V3N
DC/DC converter with 150 W from Cincon | input ranges 43 - 160 VDC | output 3.3 V | operates in temperature from -40 to +105 °C | according to EN45545-2 fire and smoke | negative control logic
-
product
PXI High Voltage Power Multiplexer, Quad 6:1
40-331A-003
The 40-331A-003 quad 6:1 MUX is part of our range of 40-331A/332 High Voltage Power Multiplexer and Matrix Modules and is suitable for applications requiring high voltage power relay switching with high density. They feature current handling up to 5A, 1000VDC/1000VAC peak cold switching and 110VDC/250VAC hot switching.
-
product
PXI High Voltage Power Multiplexer, Single 24:1
40-331A-001
The 40-331A-001 single 24:1 MUX is part of our range of 40-331A/332 High Voltage Power Multiplexer and Matrix Modules and is suitable for applications requiring high voltage power relay switching with high density. They feature current handling up to 5A, 1000VDC/1000VAC peak cold switching and 110VDC/250VAC hot switching.
-
product
HIGH VOLTAGE MEGOHMMETER
MI-10KVe
The MI-10KVe High-Voltage Megohmmeter is a truly portable device that allows the measurement of insulation resistances using test voltages up to 10 kV. It employs a state-of-the-art technology for the safe measurements of insulation resistances up to 2.000.000 MΩ with four test voltages: 1 kV - 2 kV - 5 kV and 10 kV.
-
product
Programmable Insulation/Withstanding Voltage Tester
AllWin Instrument Science and Technology Co., Ltd.
1. Electric safety wall detecting2. Test mode programmable3. ACW to DCW to IR toggle automatically4. (40.0~400.0)Hz
-
product
Raptor HV High Voltage Tester
The Raptor-HV, also called the high voltage slave, is an optional product that extends the Raptor’s applications to tests that require the use of a moderately high AC voltage.
-
product
DC/DC Converter 50 W
CTS-60-6839
DC/DC converter with 50 W from Premium | input ranges 28.8 - 60 VDC | output 5 V | operates in temperatures from -25 - +85 °C | designed according to EN50155
-
product
Reduced Voltage Motor Starting Panels by Reactors
A method to limit motor starting current is a series reactor. Iron core or air core reactors can be used for starting purposes. If an air core is used for the series reactor then a very efficient and reliable soft starter can be designed which is more suitable for high MW ratings of synchronous/induction motors at MV levels. The reactors are designed with taps.





























