product
Load Banks
Power House Manufacturing, Inc.
Load banks manufactured by Power House are engineered to be smaller and lighter than the competition.
-
product
Electric Servo Motor Type High Speed, High Load, Large Displacement Vibration Tester
This tester is a high-speed, high-acceleration vibration tester equipped with an electric servomotor actuator.
-
product
High Load Strength Tester
HLST1000Z
This tester measures the tensile or compressive strength of various samples
-
product
Multifunctional DC Electronic Load (CC/CV/CR/CP)
PLZ-5W/5WZ Series
The PLZ-5W Series high performance electronic load is the successor to the highly respected PLZ-4W series, whilst still retaining the same high specification and build quality. Advances include a high visibility color display, low voltage operation from a minimum of 1 V to a maximum of 150 V. Programmable profiles of voltage/current can be applied (using the new ARB function, as used in LED/solar testing) in addition to the inherited 6 modes of operation: Constant Current, Constant Resistance, Constant Voltage, Constant Power, Constant Current + Constant Voltage, Constant Resistance + Constant Voltage.
-
product
Portable Hand Held Load Cell Indicator
MODEL SSI
The SSI is a Plug & Play Smart TEDS IEEE 1451.4 compliant portable handheld Load Cell Indicator. Just plug in a TEDS compatible Load Cell or Torque Sensor and the SSI will automatically self-calibrate. When used with a non-TEDS Load Cell or Torque Sensor, the SSI can be set up by simple front panel push buttons. The SSI can be scaled to a full 5 digit display from 0 to 99,999 counts to read directly in engineering units such as grams, ounces, pounds, inch pounds, etc. The SSI also has a Units key for automatic conversion of readings for load, torque and pressure. The SSI has an ultra-fast signal-sampling rate of 15,360 samples/second for true peak and/or valley testing capability. Auto-tare allows the meter to be set to zero for any input signal level. The SSI also features a USB port for data logging to a PC. You can also log data to the SSI’s internal memory storing up to 16,000 time and date stamped readings. The SSI also features 2 built-in solid-state alarm relays with LED and audible indicators. The SSI will operate up to 65 hours on a single charge or use the included battery charger for applications where the SSI is mounted permanently.
-
product
PXI Load Resistor Module 40 Ohm to 295 Ohm
40-292-011
The 40-292 module is able to simulate the common short circuit and open circuit conditions that can be experienced in a system due to faulty wiring or sensors. The short circuit position is fully thermally protected and provides a short circuit current limit. The series open switch provides an automatic current limit through the resistor chain and is thermally protected.
-
product
Controllable, Programmable Linear DC Source With Load
LAB / SLR
*Linear laboratory power supply*Integrated electronic load*Automatic range selection*Linear regulated DC source with automatic range selection*Built-in electronic load*Short-term peak load operation 240 or 480 watts*Protection against short circuit, overload and overtemperature*Double current / double voltage through "autoranging"*Fast control times approx. 250µ
-
product
DC Electronic Load
3310F Series
Each 3310F Series module has its own control and display panel, CC/CR/CV/CP/Dynamic modes, plug in 3300F with 150 sets Store/Recall memory which provides load set-up more efficiently,also can be controlled intranet via RS232、Ethernet、USB and GPIB interface.
-
product
Water Cooled Active Resistance DC Electronic Load
WRx Series
Utilizing Magna-Power’s new patent pending Active Resistance Technology in combination with the company’s internally manufactured microchannel water-cooled heatsinks, the WRx Series addresses high power DC applications where exhaust heat control is essential. The WRx Series greatly increases power density compared air-cooled alternatives. An integrated solenoid controls the flow of water to avoid condensation. Full power can be achieved using conventional water, with water inlet temperatures up to 25 °C.
-
product
LED Test Programmable DC Electronic Load
IT8912E Series
IT8900 series high accuracy LED specific testing electronic loads can simulate the real output of LED lights with different characteristics.Their specific circuit can realize CR-LED mode, adjustable frequency, duty ratio PWM dimming output port (frequency: 20Hz-2KHz), I-pp/I-max measurement function can test current ripple and start up surge current of LED constant flow source. Voltage and current testing speed can reach 50KHz. IT8900 series provides CR-LED / CC / CV + CC / CR /CW and other working modes, built-in USB / RS232 / GPIB communication interface. Widely used in LED driver power dimming test.
-
product
Portable Load Cell System
Load Cell is designed by Seismic Source Company to measure the Hold Down weight and the output force of the Servo Hydraulic Vibrator unit. The output of the Load Cells can be recorded with any accurate seismic recording system.
-
product
Programable Power Supply & Programable Electronic Load
EL-820P
*Digital button control and easy operation*High resolution(20mV, 10mA, 0.1W, 0.1Ω)*Overload prevention function*9 sets programmable memory*4 sets real time display*Voltage range: 1V~63V*Current range: 10mA~15A*Maximum power: 200W*Operation mode: CV, CC, CP and CR*Built in USB interface
-
product
6kW Regenerative DC Electronic Load (CC/CR/CV/CP/CC+CV/CR+CV)
PLZ6000R
PLZ6000R is a DC electronic load that regenerates load power to the AC line. Regular electronic loads consume load power by having semiconductor devices convert it into heat. By contrast, PLZ6000R converts load power into reusable electric power, rather than converting it into heat as is typically done, and feeds this power to the AC line, thereby substantially reducing the amount of waste energy. PLZ6000R is an environment-friendly electronic load that can contribute significantly to your energy saving efforts.
-
product
3U VPX RL Thermal Load Simulation Module
The 3U power test module is an ideal solution for evaluating heat dissipation in a rugged conduction cooled VPX cage or chassis. This card is a thermal load in the chassis to evaluate the heat dissipation. The chassis can be monitored with temp sensing probes and or FLIR imaging. Different wattages are selected by setting dip switches. The +5 and 3.3V loads are on the top of the module. The +12V and -12V loads are on the bottom side of the module.
-
product
Sequence Creation Software for Power Supplies and Electronic Loads
Wavy Series
WAVY is sequence creation software that supports the power supplies and electronic loads from KIKUSUI Electronics Corp.
-
product
Low Profile Compression Only Load Column Load Cell with Mounting
CLC SERIES
Our CLC Series is our high capacity compression only load cell, featuring low profile compact size for a wide range of portable and dedicated applications. The loading diameter (D1) is slightly convex for accurate load distribution. Low deflection through design results in ultra fast frequency response. All ranges are made from 17-4ph heat treated stainless steel and incorporate a stainless steel molded connector system designed to resist washdown and splash. The mating connector, sold separately, is available in three different cable lengths.
-
product
Receiver, I2 Micro ICon, 120/12 Position Hybrid, Loaded With Twin Female Contacts (610 138 200)
310130104
The i2 Micro iCon receiver is a one piece connector capable of holding up to 120 Signal QuadraPaddle contacts and 12 Micro Coax or Micro Power. QuadraPaddle modules are molded on .100” (2.54 mm) centers to meet the need for high-density I/O in a compact assembly. This i2 receiver is pre-loaded with twin female contacts, QuadraPaddle Part # 610 138 200. Accessories such as keying pin kits, protective covers, and strain relief are available.
-
product
AC Electronic Load
The electronic AC loads cover a wide variety of different voltage, current and power ranges. All the AC loads are programmed with 11 different sine, square and DC waves. With 5 crest factor variations of each, a total of 55 waveforms are available. An external input is also provided to enable the user to amplify signals from a waveform generator.AC Loads allow real world operating conditions to be simulated. Typical applications include circuit breaker, transformer & UPS output testing along with general laboratory and research work.
-
product
2 Way GPS / GNSS Signal Splitter Passive, 1-2 GHz, SMA, DC Block+200Ω Load 2 Ports
GPS212
INSTOCK Wireless Components, Inc
GPS L1 - L5, GLONASS, Galileo splitterLow Insertion Loss (0.2 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.10 : 1 avg)15 VDC & 75 mA max on DC block portsTri Alloy SMA Female (Jack) 50 Ohm
-
product
Partial Load Failure
PLF Device
The control device series “PLF” has been designed to monitor the partial and/ or total failure of the alternating current absorbed by loads driven by static switches and / or electromechanical relays.
-
product
Load Cells
Instron is the only testing system manufacturer that designs and builds its own load cells, ensuring exceptional accuracy, stiffness, and alignment across a wide measurement range. Produced at Instron’s High Wycombe, UK facility, each load cell is temperature-compensated and calibrated to international standards for outstanding repeatability. Backed by the largest commercial deadweight stack in the U.S., Instron’s calibration process delivers precision that often exceeds industry requirements—providing reliable, traceable performance for even the most demanding materials testing applications.
-
product
LOADED BOARD TEST PROBES
SERIES-70
ElectricalMAXIMUM CURRENT: 5 amps continuousat working travel, non-inductiveRESISTANCE: At 35mA test current70 18 mOhms mean73 60 mOhms mean74 40 mOhms meanMaterials and FinishesPLUNGER: Heat treated beryllium copperor steel hardened to 55-60RC70 24Kt gold plated over nickel73 24Kt gold plated over nickel74 Rhodium plated over nickelBARREL: Nickel silver70 24Kt gold plated ID and OD over nickel73 No Finish74 24Kt gold plated ID and OD over nickel
-
product
Digital Roller Brake Tester for Cars and Vans up to 4.0 T Axle Load with 2 x 4 kW Drive Motors and Max. Track Width of 2,200mm
C_MBT C 4.0 W220 | VP 210156
Maschinenbau Haldenwang GmbH & Co. KG.
Digital roller brake tester for cars and Vans up to 4.0 t axle load with 2 x 4 kW drive motors and a max. track width of 2,200 mm.Particularly suitable as stand-alone tester or as part of car reception and diagnostic test lanes with high vehicle throughput and increased loads.
-
product
Micro Power or Micro Coax, Insert, ITA, SIM, 2 Pos, 2 Slot (not loaded)
510181104
Not loaded. Micro Power or Micro Coax patchcords need to be purchased separately.
-
product
Oscilloscope, 200 MHz, 2 GS/s interleaved, 4 CH, 200 Mpts/Ch interleaved, Fully Loaded DSO with 16 Dig Ch MSO
T3DSO2204HD-MS
The T3DSO2000HD series of Bench Oscilloscopes feature 4-channel models with analog bandwidth options of 100 MHz, 200MHz and 350 MHz. The T3DSO2000HD Oscilloscopes use 12-bit high resolution ADCs and a low noise front end which provides an impressive noise performance to cover a wide range of measurement applications. Each model offers a maximum sample rate of 2 GSa/s (interleaved) and a maximum memory depth of 200 Mpts in interleave mode. The MS configured models also include a 16 channel logic probe as standard.
-
product
High Current DC Load
3350F Series
3350F has its own control and display panel, CC/CR/CV/CP/Dynamic modes, 150 sets Store/Recall memory which provides load set-up more efficiently, also can be remote controlled via GPIB, RS232、USB and LAN interface.
-
product
Micro Power or Micro Coax, Insert, Receiver, SIM, 2 Pos, 2 Slot (not loaded)
510180104
Not loaded. Micro Power or Micro Coax patchcords need to be purchased separately.
-
product
Four-Wheel Drive Dingle Roller Dynanometer for Cars with Axle Load of up to 2.4T, for Installation in an Existing LPS 3000 Dynanometer
MSR 500/2 CAR 4WD (LPS 3000) | VP 230038
Maschinenbau Haldenwang GmbH & Co. KG.
The MSR 500/2 CAR 4WD single roller dynamometer is used in workshops for designers and tuners as well as in educational institutions. It is especially suitable for performance measurements, tuning and diagnostic work on particularly powerful vehicles. With test speeds of up to 300 km/h, it is used for dynamic and static power measurement. The MSR 500/2 CAR 4WD guarantees optimum measurement accuracy and reproducibility through the active measurement of the towing power.The rolling behaviour of the tyre is the same as on the road. Operating methods such as load simulation, including optional modules for the measurement of external data, e.g. driving cycles, are possible.The MSR 500/2 CAR 4WD is suitable for installation in an existing LPS 3000 base.
-
product
Load Cell Displays
We carry a wide range of digital displays for strain gage load cells. There are many options available to our load cell displays such as analog outputs to interface with a PLC, digital outputs for computer interfaces, I/O and relay outputs to control batching and checkweighing scales, and wireless load cell indicators.