RjP-600 Series -
Laser Probe Inc.
The RjP-600 Series energy probes integrate the detector and preamplifier in the same enclosure, thereby maximizing signal integrity between the detector and preamplifier. This permits longer cable runs between the probe and instrument, as is often necessary in production environments. Probe specific information, like calibration date and wavelength response curves, is stored in the probe for access by the instrument. Other features include interchangeable filter holders and ¼-20 mounting hole.
-
Sciencetech, Inc.
This solar simulator is based on a Fresnel lens to collimate the light beam from the arc lamp source to infinity, which results in highly collimated illumination of the target spot. A 2.5kW xenon ozone free lamp is used as the light source. The spectral distribution of the xenon light source, along with the use of specially calibrated AirMass filters, closely simulates the sun’s true spectral distribution in various conditions on Earth.
-
Pacific Instruments, Inc.
Series 6800 for portable applications is a ready-to-run, high performance measurement system that is DC powered for mobile applications. All connections are front mounted for easy installation in tight places or on the go. 6800 systems come equipped with a conditioner, amplifier, filter and digitizer. Each channel has a front mounted connector specific to a measurement type: RJ-45 for 8-wire bridge transducers or BNC for voltage or ICP/IEPE inputs.
-
Spectrometer 3090 -
TSI Inc.
The Engine Exhaust Particle Sizer 3090 (EEPS™) spectrometer measures the size distribution of engine-exhaust particle emissions in the range from 5.6 to 560 nm with the fastest time resolution available. Users can visualize and study the dynamic behavior of particle emissions that occur during transient test cycles, during the first few seconds of a cold start, or during regeneration of a particle trap or diesel particulate filter (DPF).
-
780877-01 -
NI
Non-Enclosed, 4-Channel, 14 S/s Aggregate, ±80 mV C Series Temperature Input Module - The sbRIO‑9211 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The sbRIO‑9211 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range. Non-enclosed modules are designed for OEM applications.
-
CAL1 -
Image Engineering GmbH & Co. KG
The one light source solution in the field of camera characterization and calibration. CAL1The CAL1 calibration light source is designed to characterize and calibrate cameras in the lab or on the production line. Its compact design consists of one iQ-LED element in a 0.3 m integrating sphere that illuminates a 70 mm opening. Because of the non-reflective special diffusor filter on the sphere opening, a uniformity of more than 98% could be reached
-
North Atlantic Industries
NAI designs and manufactures a full line of Commercial Off-the-Shelf (COTS), Modified COTS and Custom Power Supplies - including configurations that meet VME, cPCI and VPX (VITA 62) requirements. All comply with environmental standards designed for harsh environments, including MIL-STD-810G, VITA 47 and MIL-STD-901. NAI’s rugged power supplies also have integrated EMI filters per MIL-STD-461 standards.
-
Models 3888 And 3889 -
KANOMAX USA, Inc.
Kanomax’s innovative Handheld Particle Counters (Models 3888 & 3889) set the standard of instrumentation in cleanroom / operating room monitoring and verification, filter testing, IAQ investigation, data center cleaning and many more highly specialized and highly sensitive applications. These beautifully engineered devices boast some of the most highly advanced technology in the industry. A combination of accuracy and practicality, these devices count airborne particles with high quality performance.
-
M-1141X -
MULTI MEASURING INSTRUMENTS Co., Ltd.
・Waveform display is possible with connection to a smartphone・Measurement data is to be accumulated in the server, and it is available for graph and CSV output・Auto 5-range : AC 30mA / 300mA / 3A / 30A / 300A・CT inside diameter : φ40mm・Minimum resolution : 0.01mA・Maximum value hold / Data hold function available・Band path filter with center frequency (fo = 55Hz)・Compliant with EN 61010, CAT-III 1000V / CAT-IV 600V・With backlight
-
M-1141XR -
MULTI MEASURING INSTRUMENTS Co., Ltd.
・Waveform display is possible with connection to a smartphone・Measurement data is to be accumulated in the server, and it is available for graph and CSV output・Auto 5-range : AC 30mA / 300mA / 3A / 30A / 300A・CT inside diameter : φ40mm・Minimum resolution : 0.01mA・Maximum value hold / Data hold function available・Band path filter with center frequency (fo = 55Hz)・Compliant with EN 61010, CAT-III 1000V / CAT-IV 600V・With backlight
-
fcXplorer Simulyzer -
Avionics Interface Technologies
FC-1, FC-2, and FC4 Analyzer modes and displays - Frame parser for custom display of FC frames and payload data - Captured data can be saved as binary or “csv” files - User-defined trigger and filter features - “Live Capture” real-time display - Error detection and reproduction - Complete control of the transmit link - Replay of recorded data with precision timing or corrected protocol timing - Special testing functions such as defining command/response for exchange management
-
Model 1072 -
Aplab Limited
Aplab Psophometer is a portable unit designed for the use of testing telecommunication equipment. It has Psophometric filter, which has the frequency response of the weighing network based on the CCITT recommendations and frequency response characteristics for unweighted measurements. The additional features included in this model are, ‘Recorder out’ available at the rear panel for plotting a response curve, built-in stable calibration signal for calibration check and Lo Battery facility to check the Battery condition.
-
Anton Paar GmbH
These Anton Paar instruments enable you to evaluate the oxidation stability as well as the storage and thermal stability of mineral oil products or oil and fat containing cosmetics and food samples. The gum content tester is available for tests on the gum content of fuels and other volatile distillates. Cold flow properties (cold filter plugging point and cloud and pour point) show the lowest temperature for a trouble-free operation of diesel fuel or heating oil.
-
Kuhne electronic GmbH
. Internal filters provide high spurious rejection and image rejection. Due to low phase noise and high frequency stability of the local oscillator at 3000 MHz, the up converter is suitable for analog and digital communication systems.Typical applications are Multichannel Multipoint Distribution Systems (MMDS) using QPSK modulation and DVB?T or DVB?S systems. The output power of 20 mW can be increased to several watts by the use of an additional power amplifier.
-
PI-41701 -
Pulse Instruments
The PI-41701 is a dual channel bipolar DC Bias supply that can provide an output current up to 100 mA per channel. The output voltage ranges from –8 V to +8 V and features programmable current limits with LED indicators and software interrupt to show/alert the user if the channel is in current limit. This card has special filter circuitry to reduce the output noise for those applications that require a low noise bias output.