Loop backs
connect input to ouput to test I/O loop.
-
Product
Micro-Ohmmeter and Loop Resistance Tester
LRT 6000
-
LRT 6000: The right solution for impedance resistance measurement in compliance with all aircraft specifications on plane, helicopter, rocket, army vehicles for both production andmaintenance. It is a very easy-to-use and versatile instrument. Its ergonomics allow the user to use it either placed on the ground or across one's shoulder or chest. Awide back-lit LCDdisplay combinedwith an intuitive keyboard ensures simple and easy operation.
-
Product
MULTI-STANDARD LOCAL LOOP SIMULATOR
458-LM-A8-30
-
Accurately simulates attenuation and impedanceFull bidirectional operation at all specified frequencies26 AWG PIC as specified in ANSI T1.417
-
Product
Model QLS 4-20 mA Loop Splitter / Retransmitter
-
Generates up to four individually grounded and individually adjustable 4-20 mA loops from a single 4-20 mA or 0-10V input. Overcomes problems which occur when the same 4-20 mA signal is applied to multiple loads in series. Allows outputs to have different grounds, and allows individual loops to be opened without affecting signal to other loads.
-
Product
1310/1550 nm Dual Laser Source Back Reflectiom/Power Meter
GM8019 + GM83001E
-
The UC INSTRUMENTS GM8019 + GM83001E 1310/1550 nm dual laser source back reflection meter and power meter is a compact, direct display instrument for the convinent measurement of backreflection, insertion loss and power connector, fiber optic components, and system. With a single output port, the meter is very easy to use and ideal for fiber cable jumper manufacturers.
-
Product
THREE WAY BACK PRESSURE KIT
TU24APB
-
*Allows quicker and more accurate testing of exhaust blockages in catalytic converters, mufflers, etc*2-1/2" gauge features two multi-colored bands - idle and 2,500 RPM - with pressures shown in PSI and bar*Includes 6' of hose, enough length to test from driver's seat
-
Product
Phase Locked Loop with Integrated VCO
-
PLL with integrated VCOs provide local oscillator sources and clock sources for communications (COMMS) , test and measurement (ETM) and aerospace/defense (ADEF) applications. ADI's PLLs with integrated VCO portfolio includes both narrowband and wideband parts, supporting frequencies up to 13.6GHz. Our PLLs with integrated VCO, as well as our full PLL portfolio including integer-N and fractional-N PLLs, feature best-in-class performance for phase noise, jitter, and spurious, and also feature high levels of integration in small form factor packages.
-
Product
PXI/cPCI Programmable Power Supply - 16-bit Read Back Voltage and Current at Output
52912
Programmable Power Supply
Chroma 52912 programmable DC power supplies are designed specifically for test applications that demand precision output voltage/current and tightly coupled measurement capabilities.
-
Product
Dynamic Scale Deposition Loop System
-
Dynamic Scale Deposition Loop fully automated systems includes hardware and software to measure and evaluate the performance of scale inhibitors under high pressure and high temperature conditions.
-
Product
Loop Testing
-
Megger loop testers offer both traditional measuring techniques and state of the art “non-RCD Tripping” technology. Use these products to determine the prospective earth fault current, which is the maximum current able to flow in a phase-earth fault in an installation, and also to indicate the prospective short circuit current which is the maximum current able to flow in the event of a phase-neutral fault.
-
Product
mA Loop Calibrators
-
AMETEK Sensors, Test & Calibration
Our mA loop calibrator is an economical and easy-to-use calibration device for sourcing and measuring mA signals. Measure and source current to 24 mA and measure voltage to 45 VDC. Combine our 24VDCPS with one of our handheld pressure calibrators to calibrate transmitters in the field.
-
Product
mA Loop Calibrators
-
Loop Calibrators are indispensable tools for process calibration professionals and we have just one you need. Choose from three different models depending on your need for accuracy and intrinsic safety. Each one is feature-rich and simple to operate and read.
-
Product
Closed Loop Hall AC/DC Current Sensor
CYHCS-D8
-
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used for measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the real wave of the current in the carrying conductor.
-
Product
Pump Back Gas Analyser
Rapidox SF6 6100
-
The Rapidox SF6 6100 Pump Back is the latest in fully-automatic gas analysers, designed for controlling and monitoring the quality of SF6 in medium & high voltage gas insulated electrical equipment. Exceptional accuracy and stability are provided when measuring the purity of SF6 gas, through specially selected sensors.
-
Product
Level Control Loop Trainer Model
ULP-24P & ULP-24C
-
Unitech Scales And Measurements Pvt. Ltd
Unitech’s Level Control Setup comprises of acrylic measuring tank fitted with Level transmitter, control valve, I to P converter, source tank with water pump and necessary flexible piping for water circulation. The system is mounted on a table top powder coated metal frame. Level transmitter is of capacitance or DPT type sensor. The electronic panel comprises of ADC and DAC card with RS-232 interfaces.
-
Product
Line Loop Tester
8455
-
Simpson?s Model 8455 Line Loop tester detects line shorts, opens and multiple ringers, DC voltages and loop resistance. It can measure DC voltage up to 100 volts and loop resistance to 2 megohms. A front panel ?reverse polarity? switch allows changing polarity positions quicker and easier than manually switching test leads when making line checks.
-
Product
Helmholtz Coils / Radiating Loops
-
Formed by a pair of conducting circular coils with many turns, each carrying a current. The coils are separated by a distance equal to the radius of the circular loops.
-
Product
PXI/PXIe Analog Output/Current Loop Simulator Module - 4 Channel
43-765-004
Analog Output Module
The 41/43-765-004 is an 4-channel Analog Output Module designed to meet the requirements of industrial control applications utilising current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signalling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
Product
Antenna, Loop Sensor
EM-6873 | 20 Hz – 100 KHz
-
The EM-6873 Loop Sensor Antenna uses passive circuits to transform magnetic field components between 20 Hz – 100 kHz to an equivalent open circuit two-terminal voltage on the receiving instrument. Use of the conversion Factor Chart, supplied with each antenna, will yield the strength of the magnetic induction field referenced to a uniform field. The loop is electrostatically shielded and therefore is sensitive only to the magnetic component (B-field) of the electromagnetic fields.
-
Product
Panel-mounted Power Amplifier(Hardware In The Loop Testing)
PA60Bi
-
PA60Bi is the panel-mounted power amplifier, which can produce 3-phase current, with maximum RMS phase current of 60A and maximum output power of 800VA, and 4-phase voltage, with maximum RMS phase voltage of 120V and maximum output power of 60VA.
-
Product
Closed Loop Precise Hall AC/DC Current Sensor
CYHCS-LF
-
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used for accurate measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the real wave of the current carrying conductor.
-
Product
Rapidox 6100 Pump Back Gas Analyser
-
The Rapidox SF6 6100 Pump Back is a fully-automatic zero-emissions SF6 gas analyser, designed for controlling and monitoring the quality and purity of gas used in high voltage switchgear, circuit breakers and transformers.
-
Product
PXI/PXIe Analog Output/Current Loop Simulator Module - 16 Channel
43-765-001
Analog Output Module
The 41/43-765-001 is a PXI/PXIe 16-channel Analog Output Module designed to meet the requirements of industrial control applications utilising current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signalling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
Product
Loop Calibrator
Model KM CAL-904-MK1
-
Kusam Electrical Industries Limited
• 4-20mA (1kΩ Load, 24V Loop Output).• 0-20mA and 0-24mA output ranges.• 0.025% Basic Accuracy.• Auto Ramp and Step functions.• 0-100% output with percentage step option.• 0-24V DC voltage source.• Open loop and overload buzzer alarm.• Low battery indication.• Simple Operation Interface• Warning beeper when output is open• Pollution Degree 2.• Ambient temperature 0~40℃.• Power Consumption 150mA at 24V 1kΩ load
-
Product
High Current Short Circuit Loop Impedance Meter
AMZC-310S
-
Measurement of very small short-circuit loop impedances (with resolution of 0,1mΩ) using the current of 150A under 230V, maximum 280A under 440V, or measurement using the current of 23A under 230V, maximum 42A under 440V
-
Product
PXI/PXIe Analog Output/Current Loop Simulator Module - 8 Channel
43-765-003
Analog Output Module
The 41/43-765-003 is an 8-channel Analog Output Module designed to meet the requirements of industrial control applications utilising current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signalling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
Product
Exhaust Back Pressure Tester
33600
-
Use to test for clogged or obstructed catalytic converters and mufflers. Fast and easy to use - threads into Oxygen Sensor Port. Includes 12mm and 18mm adapters to fit most domestic and imported vehicles. Gage measures 2 1/2" diameter and has dual scale: 15 PSI and 1.00 Kg/Cm2. Hose is 41" long.
-
Product
Antenna, Loop
EM-6871 | 30 Hz – 1 MHz
-
The EM-6871 Antenna can be used with any 50 ohm /Receiver/Field Strength Meter to obtain magnetic field measurements from 30 Hz to 1 MHz.
-
Product
Antenna, Loop
EM-6879 | 10 KHz – 30 MHz
-
The EM-6879 Loop Antenna is used for magnetic field measurements over the frequency range of 10 kHz to 30 MHz. The EM-6879 is designed for use with any 50 ohm Receiver System. The antenna has a balanced Faraday shield that reduces its response to electric fields to a vanishingly small amount so that it can produce a practically pure magnetic field response.
-
Product
PXI Analog Output/Current Loop Simulator Module - 8 Channel
41-765-003
Analog Output Module
The 41/43-765-003 is an 8-channel Analog Output Module designed to meet the requirements of industrial control applications utilizing current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signaling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
Product
Recorder for non-stop(Loop)
-