An accurate current units of measure to facilitate comparison to and adjustment of instruments.
-
Product
Leakage Current Clamp Mete
-
Basic functions:AC current:20mA resolution: 0.01mA, ± (2.5%, +5)200mA resolution: 0.1mA, ±(2.5%, +5)2A resolution: 1mA, ±(2.5%, +5)60A resolution: 100mA, ±(3%, +8)AC voltage: 600V, ±(0.8%, +5)DC voltage: 600V, ±(0.8%, +5)Special functions:Auto ranging Low battery display Data hold Auto power-off Over-load protection Input impedanceDC voltage measurement: ≥10MΩ Sampling frequency: 3 times/s Maximum display: 1999 Maximum distance between clamps: 30mm General characteristics:Product colors: iron-gray and redProduct net weight: approximately 136gLCD size: 25x36mmProduct size: 183x63x29mmPower: 2x1.5V, 7#Standard accessories: packing carton and handheld bag English user's manual and battery
-
Product
Current Tester
MIG0624
-
The MIG0624 current tester is designed to test surge protection devices for low voltage applications (<1000 V). MIG0624 is a current generator delivering a 8/20 µs impulse up to 24kA. The exact waveform delivered is a function of the surge generator and the impedance to which the surge is applied.
-
Product
Calibrator Process
VA70034
-
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
Loop calibrator This Calibrator is use to measure or output 0 to 24 mA DC current loop, and 0 to 20 V DC voltage.
-
Product
Trace-Level Dilution Calibrator
Model T700U
-
Teledyne Advanced Pollution Instrumentation
The Model T700U is a microprocessor based calibrator for precision, trace-level gas analyzers. Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and zero checks using up to 4 gas sources.In addition to the features of the Model T700, the Model T700U is designed for the demanding requirements of trace-level measurements. The ability to calibrate and verify linearity for NO2 at levels below 50 ppb is difficult with standard calibrators. To overcome this limitation, the Model T700U ozone generator operates in two modes; a high range with similar performance to the Model T700 ozone generator, and a low range, or "fractional" mode, for producing accurate ozone levels down to 3 ppb. To ensure the highest accuracy of NO2 output, the calibrator measures the ozone concentration prior to performing a GPT, and the range is selected automatically by the Model T700U based on ozone concentration and flow specified by the user.
-
Product
Current Probe
DCP-BTA
-
Vernier Software & Technology, LLC
The Current Probe measures DC and low-frequency AC currents up to 600 mA. Use Current Probes in combination with Differential Voltage Probes to investigate Ohm's Law and explore series and parallel circuits. The 0.1 shunt resistor minimizes changes to your circuit. If currents will exceed 1 A, use the High Current Sensor.
-
Product
Impulse Current Generator
-
Weshine Electric Manufacturing Co., Ltd
Impulse current generator is mainly used to test the ability of electrical equipment to withstand strong impulse current, widely used in lightning arresters and electrical and electronic equipment in operation conditions of oscillation wave immunity test, can also be used for other research tests.
-
Product
Calibration / AVP Service
-
Comware Technical Services, Inc.
Regular calibrations / AVPs will help ensure the measurement integrity of your system. We supply the calibration equipment or you can provide us with your own in-house equipment.
-
Product
Low Current Probe/DMM
687
-
With the capability of measuring down to 1 milliamp (.001A), the #687 is a great tool for all low current applications. Especially for diagnosing parasitic drains! Clamp opening is large enough to fit over most negative battery cables. Applications: fuel injectors, fuel pumps, electric motors, battery drains, charging systems.
-
Product
AC/DC Clamp-On Current Transformers
-
AC/DC Clamp-On Current Transformers by AYA Instruments
-
Product
Current Loop 20 MA Constant Current SI-module With Optical Isolation
MXTTY
-
Current loop 20 mA constant current (active, passive) SI-module with optical isolation.
-
Product
Partial Discharge Detection Calibration Device
-
Hangzhou Xihu Electronic Institute
Calibration Device of Transient Earth Voltage PD detector, calibration device of ultrasonic PD detector, calibration device of high frequency PD detector, calibration device of ultra high frequency PD detector.
-
Product
Field Current Regulator
-
We are counted amongst the leading names in the industry, offering wide range of Field Current Regulator. Our entire product line ensures easy operations and is performance based. Field Current Regulator are quality tested and are delivered in standard configurations. Our entire product range has high strength and is delivered at most affordable rates.
-
Product
Waveguide Calibration Kits
-
Designed to provide accurate calibration of vector network analyzers (VNAs) that are used for measurements in standard rectangular waveguide from 2.6 to 50 GHz (WR284–WR22).
-
Product
Primary Current Injection Sets
-
Protective devices such as relays, overload Coils, Circuit breakers and CTS etc. must be checked regularly to ensure that they are always ready to operate correctly, Routine current injection testing will quickly detect faulty or incorrectly adjusted protection circuits / devices & will be possible to prevent serious damage to the system. Primary injection kit is designed to operate on single phase 230/240 volts AC 50 HZ to develop smooth & continuous test current as for loading, calibrating, and testing of CTS, Bimetal Relays, Protection Relays etc. The test set gives high current output at low cost and with inherent safety. The primary current injection testing checks all parts of the protection system by injecting current down the cable / bus bars. The application of the primary current injection sets is to ascertain the current carrying capacity of any Conductor, insulator, connector or calibration of CTS / Bi-metallic relays etc.
-
Product
Current Transformer with Open Core
TCP
-
Lifasa - International Capacitors, SA
The TCP series is designed for installations in operation. It has a removable core that allows its connection without interrupting the power supply.
-
Product
6GHz SMA Calibration Kits
CAL-SMA-6F
-
The CAL-SMA-6F Full calibration kit provides all elements for Male and Female Open-Short-Load and Through calibrations for one and two port VNA measurements.
-
Product
Power Supply and Current Monitor
DC Connect
-
DC Connect enables measurement of current consumption of battery operated and other low voltage devices such as hearing aids
-
Product
Calibrating Equipment
-
Stability DC : < 0.01 %FS / 3 min, AC : < 0.02 %FS / 3 minRipple : < 0.2 %Power Supply : 230 VAC, 50 (60) HzPower Consumption : < 250 VAOperating Temperature : 5ºC to 35ºCRelative Humidity : ≤ 80 %Distortion : < 0.5 %Display : 51/2 Digit LED Digital DisplayStep adjustment of Output Signal : 100 %FS / N, 10 %FS / N,%FS / N, 0.1 %FS / N (N = 4, 5, 6, 10 and 15)Dimensions : 190mm (H) x 480mm (W) x 545mm (D)Total Weight : 22.5 kgs (approx.)
-
Product
Calibrators
-
Our high accuracy calibrators work with all competitor products and offers the customer a way to maintain their equipment, while keeping the specifications of their process.
-
Product
Calibration Test Pumps
-
High-precision calibration & pressure testing is the key to success in the oil & gas, petrochemical, maritime, pharmaceutical and aerospace industries and the right calibration tools make all the difference. Ralston Instruments offers a wide array of intelligently designed, high-quality calibration test pumps that simplify complex calibration processes while providing fast, accurate results. All Ralston pressure test pumps are lightweight, extremely durable, and easy to disassemble and repair with standard hand tools. And for quick connectivity with the most effective results, they all come with Ralston Quick-test™ adapters for safe, stable, leak-free connections without the need for a wrench or thread tape.
-
Product
Calibration Management Software
MET/CAL®
-
MET/CAL software is structured around the flow of instruments through the calibration process and addresses a wide range of test and measurement instrument calibration needs, from the simple to the complex. It is based on the traditional calibration model as its framework—comparing an instrument to a standard of known uncertainty.
-
Product
Calibration Test Benches
-
Nagman Instruments & Electronics Pvt. Ltd
Nagman’s wide range of Calibration Systems – Test Benches, Workstations, Bench-tops & Mobile Units – are designed & executed to serve as Powerful tools for Total Quality Management & ISO Conformance with Accuracies Traceable to International Standards and Total Solution to all Calibration requirements.
-
Product
Temperature Calibrators
-
We offer temperature calibrators in different shapes. We offer temperature dry blocks that can generate an accurate temperature, for example for temperature sensor calibration. We also offer electrical temperature calibrators that can measure and simulate various temperature sensors (RTDs and thermocouples). We also offer high-accuracy reference temperature probes.
-
Product
Precision Current Shunt
-
Has five precision selectable Ultra stable Current Shunts which ranges from 0.0001 to 1Ω. The Shunt T/C is less than 10ppm, and the internal current meter will measure from 1μA to 1000Amps.
-
Product
Portable Trace-Level O3 Calibrator
Model T753U
-
Teledyne Advanced Pollution Instrumentation
The Model T753U is a portable, microprocessor based precision Calibrator for Ozone gas instruments and sensors. Using a sophisticated Ozone generation system, combined with a sensitive photometer and pneumatic design, the T753U produces stable and reliable concentrations of Ozone in a convenient and rugged package based on our popular T750U Portable Multigas Calibrator platform. The T753U is housed in a high-density, molded travel case which includes an integral handle and wheels for durability and ease of use in the field for virtually any application. An internal zero air option extends the T753U's capabilities to also provide a clean and dry source of zero air, eliminating the need for a separate source of zero air. The internal zero air source module contains a software driven electronic inlet valve manifold allowing the calibrator to automatically switch between internal and external zero air sources depending on the application needs.
-
Product
Power Calibrators And Power Quality Calibrators
-
Calmet Smart Calibration Devices
A power calibrator and a power quality calibrator are both specialized instruments used to verify and adjust the accuracy of other instruments, but they focus on different aspects of electrical power.
-
Product
Current Pulsers and Laser Diode Drivers (Pulsed Current)
-
These instruments generate current pulses whose amplitude is largely independent of the load voltage. This makes them ideal for pulsing device whose voltage may vary with time (for instance, the voltage drop of laser diodes may vary with temperature, or explosive squibs which change impedance during ignition). This voltage independence is a trade-off with speed. If faster rise times are required, consider using pulsed voltage instruments instead.
-
Product
Vibration Calibrator
SV 111
-
SV 111 vibration calibrator is the State of the Art instrument designed for human vibration measurements according to ISO 8041. The design of the calibrator is based on the triaxial reference accelerometer and microprocessor controlled shaker. These both features assure excellent stability of the calibration levels and their frequency independently from mass of the testing object, like also indicate improper test object fixing by monitoring of shaker vibration in all three axis simultaneously.