Filter Results By:

Products

Applications

Manufacturers

Digital

A signal of discrete values as opposed to a spectra of values.

See Also: Analog


Showing results: 5911 - 5925 of 6380 items found.

  • PXIe-4330, 25 kS/s, 24-Bit, 8-Channel PXI Strain/Bridge Input Module

    781346-01 - NI

    25 kS/s, 24-Bit, 8-Channel PXI Strain/Bridge Input Module—The PXIe‑4330 is a simultaneous input module that provides integrated data acquisition and signal conditioning for bridge-based sensors. The PXIe‑4330 includes increased accuracy, high data throughput, and synchronization features, making it ideal for high-density measurement systems. To remove noise, the PXIe‑4330 offers antialiasing and digital filters per channel. Each channel also features an independent, programmable excitation voltage. Additionally, the PXIe‑4330 provides remote sensing, internal bridge completion, and shunt calibration options per channel.

  • Voltage/Continuity Testers

    VOT-53 - Standard Electric Works Co., Ltd

    ● 2000-count digital display (LCD type).    ● Test leads positioned at 19mm apart.● Interchangeable probe tip for 2mm and 4mm.● Polarity test ● Audible continuity test.● Auto sensing function for: voltage (AC/DC), Ω, diode.● Measurement function:   ACV/DCV: 1000V   Resistance: 2000Ω   Frequency: 30Hz~1kHz ● Phase rotation test : ● Waterproof design, protection class: IP65.● Phase / Neutral identification.● Rubberized double-molded housing.● Flashlight function.● Safety standard :     EN 61010-1 CAT III 1000V    EN 61010-1 CAT IV 600V    EN 61243-3    EN 61326-1

  • HDMI Electrical Performance, Validation and Compliance Test Software

    D9021HDMC - Keysight Technologies

    The D9021HDMC HDMI electrical performance validation and compliance software for Infiniium V, Z and UXR-Series oscilloscopes gives you a fast and easy way to verify and debug your High Definition Multi-media Interface (HDMI) designs for set-top boxes, Digital Video Recorders, DVD players, and motherboard systems. The HDMI compliance test software lets you automatically execute HDMI electrical checklist tests and displays the results in a comprehensive report format. In addition to the measurement data, the report provides a margin analysis that shows how closely your device passed or failed each test.

  • PXIe-4339, 25 kS/s, 24-Bit, 8-Channel PXI Strain/Bridge Input Module

    783531-01 - NI

    25 kS/s, 24-Bit, 8-Channel PXI Strain/Bridge Input Module—The PXIe‑4339 is a universal bridge input module ideal for test cell installations requiring both accuracy and flexibility. Completely configurable through software, each channel can take bridge-based measurements and direct voltage measurements. Eight input ranges in ratiometric mode and four in voltage mode accommodate a wide variety of sensor types for your changing application needs. The PXIe‑4339 also features per-channel wide bandwidth analog outputs, programmable excitation, Transducer Electronic Data Sheet (TEDS) support, and digital filtering.

  • PXIe-4302, 24-Bit, 32-Channel, 5 kS/s, ±10 V PXI Analog Input Module

    783865-01 - NI

    24-Bit, 32-Channel, 5 kS/s, ±10 V PXI Analog Input Module—The PXIe‑4302 is a filtered input module for voltage, thermocouple, and current measurements. The module has an A/D converter per channel to enable a simultaneous sample rate of 5 kS/s. The PXIe‑4302 offers you the ability to select a digital filter per channel to provide extra filtering performance. You also can operate up to four different sample rates and triggering configurations concurrently to ensure you measure every sensor as needed. The included NI‑DAQmx driver simplifies hardware configuration and measurement.

  • PXIe-4144, 4-Channel, ±6 V, 500 mA PXI Source Measure Unit

    782432-01 - NI

    PXIe, 4-Channel, ±6 V, 500 mA PXI Source Measure Unit - The PXIe-4144 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. The fast sample rate of the PXIe-4144 can reduce measurement times, capture transient device characteristics, and allow quick I V characterization of devices under test (DUTs). With a high-speed sequencing engine, you can synchronize all these SMUs with each other or with other instruments such as switches or high-speed digital test modules.

  • USB-6002, 8 AI (16-Bit, 50 kS/s), 2 AO (5 kS/s/ch), 13 DIO USB Multifunction I/O Device

    782606-01 - NI

    8 AI (16-Bit, 50 kS/s), 2 AO (5 kS/s/ch), 13 DIO USB Multifunction I/O Device - The USB‑6002 is a low-cost, multifunction DAQ device. It offers analog I/O, digital I/O, and a 32‑bit counter. The USB‑6002 provides basic functionality for applications such as simple data logging, portable measurements, and academic lab experiments. The device features a lightweight mechanical enclosure and is bus powered for easy portability. You can easily connect sensors and signals to the USB‑6002 with screw-terminal connectivity. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.

  • USB-6003, 8 AI (16-Bit, 100 kS/s), 2 AO (5 kS/s/ch), 13 DIO USB Multifunction I/O Device

    782608-01 - NI

    8 AI (16-Bit, 100 kS/s), 2 AO (5 kS/s/ch), 13 DIO USB Multifunction I/O Device - The USB‑6003 is a low-cost, multifunction DAQ device. It offers analog I/O, digital I/O, and a 32‑bit counter. The USB‑6003 provides basic functionality for applications such as simple data logging, portable measurements, and academic lab experiments. The device features a lightweight mechanical enclosure and is bus powered for easy portability. You can easily connect sensors and signals to the USB‑6003 with screw-terminal connectivity. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.

  • USB-6001, 8 AI (14-Bit, 20 kS/s), 2 AO (5 kS/s/ch), 13 DIO USB Multifunction I/O Device

    782604-01 - NI

    8 AI (14-Bit, 20 kS/s), 2 AO (5 kS/s/ch), 13 DIO USB Multifunction I/O Device - The USB‑6001 is a low-cost, multifunction DAQ device. It offers analog I/O, digital I/O, and a 32‑bit counter. The USB‑6001 provides basic functionality for applications such as simple data logging, portable measurements, and academic lab experiments. The device features a lightweight mechanical enclosure and is bus powered for easy portability. You can easily connect sensors and signals to the USB-6001 with screw-terminal connectivity. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.

  • PXIe-6591, 12.5 Gbps, 8-Channel PXI High-Speed Serial Instrument

    783638-01 - NI

    12.5 Gbps, 8-Channel PXI High-Speed Serial Instrument—The PXIe‑6591 is designed for engineers who need to validate, interface through, and test serial protocols. It includes a Xilinx Kintex‑7 FPGA to implement various high-speed serial protocols, and it is programmable with the LabVIEW FPGA Module for maximum application-specific customization and reuse. The PXIe‑6591 takes advantage of FPGA multigigabit transceivers and up to eight TX and RX lanes. In addition to high-speed serial lanes, the PXIe‑6591 features digital I/O signals that support multiple logic families with per line, per cycle direction control.

  • PXIe-4331, 102.4 kS/s, 24-Bit, 8-Channel PXI Strain/Bridge Input Module

    781345-01 - NI

    102.4 kS/s, 24-Bit, 8-Channel PXI Strain/Bridge Input Module—The PXIe‑4331 is a high-speed input module that provides integrated data acquisition and signal conditioning for dynamic strain, load, and pressure measurements. This module includes increased accuracy, high data throughput, and synchronization features, making it ideal for high-density measurement systems. To remove noise, the PXIe‑4331 offers antialiasing and digital filters per channel. Each channel also features an independent, programmable excitation voltage. Additionally, the PXIe‑4331 provides remote sensing, internal bridge completion, and shunt calibration options per channel.

  • Disciplined Frequency Standard

    2975AR - Novatech Instruments , Inc.

    The 2975AR contains a rubidium timebase and provide one 10 MHz, one 5 MHz and one Signal Generator output. The Signal Generator uses Direct Digital Synthesizer (DDS) technology and is programmable from 100Hz to 50 MHz using front panel controls or from an RS232 serial interface. The 2975AR can be disciplined by a 1pps input signal and provides a 1pps output signal. The 1pps input is typically provided by the GPS Frequency output from a device like a smart GPS receiver or antenna. The Novatech GPS1 Smart Antenna is available as an accessory to provide a complete turnkey solution.

  • Super Phosphor Oscilloscopes

    SDS2000X-E Series - SIGLENT Technologies

    The SDS2000X-E series employs a new generation of SPO technology. With its excellent signal fidelity, background noise is lower than similar products in the industry. It has a minimum vertical input range of 500 uV/div, an innovative digital trigger system with high sensitivity and low jitter, and a waveform capture rate of 400,000 frames/sec (sequence mode). It also employs a 256-level intensity grading display function and a color temperature display mode not found in other models in this class. Siglent’s newest oscilloscope offering supports multiple powerful triggering modes including serial bus triggering and decoding. History waveform recording and sequential triggering allow for extended waveform records to be captured, stored, and analyzed. Also included is the deep memory FFT. This math function uses upto 1 M samples for the FFT calculation, providing the SDS2000X-E with very high frequency resolution. The hardware co-processor executes true fast measurement and math to all of 28M sample points so that there is minimal distortion on analysis. It also supports searching and navigating, on-screen Bode plot, 16 channel digital /MSO (optional), an external USB powered 25 MHz AWG function generator module (option), a USB WIFI adapter for wireless control and monitoring (option), and an embedded application that allows remote control via web browser. The features and high-performance of the SDS2000X-E oscilloscopes cannot be matched else anywhere at this price.

  • 8-Channel 250 MHz A/D with DDC, Kintex UltraScale FPGA - PCIe

    Model 78131 - Pentek, Inc.

    - Jade Xilinx Kintex UltraScale FPGA Products and Navigator Design Suite Software Video- Jade Xilinx Kintex UltraScale FPGA Family Brochure- Ideal radar and software radio interface solution- Supports Xilinx Kintex UltraScale FPGAs- Eight 250 MHz 16-bit A/Ds- Eight multiband DDCs (digital downconverters)- 5 GB of DDR4 SDRAM- Sample clock synchronization to an external system reference- LVPECL clock/sync bus for multiboard synchronization- PCI Express (Gen. 1, 2 & 3) interface up to x8- Optional LVDS and gigabit serial connections to the FPGA for custom I/O- Ruggedized versions available

  • 4-Channel 200 MHz A/D with 32-Channel DDC, Virtex-6 FPGA - 6U VPX

    Model 57662 - Pentek, Inc.

    - Complete radar and software radio interface solution- Supports Xilinx Virtex-6 LXT and SXT FPGAs- Four 200 MHz 16-bit A/Ds- 32 channels of multiband DDCs (digital downconverters)- Up to 2 GB of DDR3 SDRAM- PCI Express (Gen. 1 & 2) interface up to x8- Sample clock synchronization to an external system reference- LVPECL clock/sync bus for multiboard synchronization- Optional user-configurable gigabit serial interface- Optional LVDS connections to the Virtex-6 FPGA for custom I/O- Ruggedized and conduction-cooled versions available- Synchronize up to eight modules with Model 7893 System Synchronization and Distribution Amplifier - PCIe

Get Help