Button Cell
single cell battery 5-20 mm round and 1-6 mm thin.
-
product
Resistivity Cell For N1413 With B2980 Series (26/50/76 Mm Diameter Electrodes)
N1424C
The N1424C is designed to operate specifically with the B2985B/87BElectrometer/High Resistance Meter. It is used to measure surface or volume resistance/resistivity of insulation materials. The N1413A High Resistance Meter Fixture Adapter is required to connect the N1424C to the B2985B/87B.
-
product
Signature Compression Only Load Button Load Cells
SLB SERIES
The SLB Series Subminiature load cells (Load Buttons) are offered for compression only applications where space is limited. The matching surface must be flat for ultimate accuracy. The loading diameter is slightly convex for accurate load distribution. These sensors are manufactured from heat treated 17-4ph stainless steel, and the sensing element incorporates bonded foil strain gages of the highest quality. They are sealed for protection against most industrial environments.
-
product
Load Cells
We make it our business to stay on top of emerging industry demands so that the load cells we provide help you meet your ever-changing test requirements. Our broad selection of competitively priced load products will help you meet the most demanding test and measurement requirements. Used in automotive, aerospace and defense, R&D, and process control applications, our drop-in replacement load cells are designed to provide years of dependable performance.
-
product
Radial Flow Cell
The wall jet of the sample, after hit in to the surface of the electrode, spreads in three dimensions. After hitting the sample on a thin layer electrode directly, it flows to the perimeter from the center of the radiated electrode, improving the sensitivity.
-
product
Battery Cell Test System
PEC is the worldwide leader in cell, module and pack test equipment for advanced batteries and energy storage systems. Our test equipment combines very high control and measurement accuracy with an excellent dynamic behavior. This results in very precise, near real time simulations of demanding applications in electro-mobility, renewable energy, aerospace and defense. PEC also supplies test systems for primary batteries and consumer applications.
-
product
Advanced Lithium Cell Formation System
The Series 5302 is the latest in a series of computerized cell formation systems from Maccor, designed primarily for use in the formation of Lithium Ion and Lithium Polymer secondary batteries. New advanced features provide a greater flexibility and range of use compared with previous designs. This additional capability is even achieved at a reduced cost.
-
product
Water Filler for Nickel-Cadmium Cells
MasterFiller
The MasterFiller is an instrument designed to deliver measured quantities of distilled water as required in the service of Aircraft Nickel-Cadmium batteries.· The MasterFiller consists of a microprocessor controlled pump with a level sensing probe, a keypad and display and an external 12VDC power supply (or optional battery).· The MasterFiller is part of a system comprising Intelligent Charger-Analyzers and Software for Battery Data Acquisition and Analysis, designed to improve the accuracy and efficiency of the process of testing batteries for airworthiness certification.
-
product
Load Cell Amplifier Signal Conditioner with DB9 Connectors
MODEL LCA-9PC
The LCA-9PC Module provides low-cost, dedicated signal conditioning for a single bridge type load cell or torque sensor. Model LCA-9PC comes with DB9 male and female connectors, which require soldering to user-furnished mating female or male wire connectors. On- board jumper selections include sensitivities from 0.5 mV/V to 10 mV/V, bandwidths from 100 Hz to 30 kHz, and amplified outputs of 0 to ±5V, 0 to ±10V, 0-16 mA, 0-20 mA or 4-20 mA. Zero and span adjustments are via precision 25-turn low-tempco metal film otentiometers.The units can be operated next to the sensor with 4-wire hookup or at distances up to 1 km (3300 feet) with 6-wire hookup. An onboard 87.325 kΩ resistor allows easy shunt calibration at the push of a button. Provision is also made for a user-furnished calibration resistor. Power requirements are 11.8 to 26V DC with load currents from 10 to 60 mA, the latter applying when the unit provides 10V DC excitation to a 350 ohm load cell and delivers a 20 mA analog output.
-
product
Working Electrodes for Flow Cell
Our working electrodes for flow cell are mounted in blocks of PEEK. This resin protects the electrodes from external noise and allows researchers to utilize them regardless the content of mobile phase of HPLC because of their hardness and organic slovent-resistance. Glassy carbon is usually chosen for the redox reaction study on liquid chromatography. Platinum, Gold, Carbon paste and Nickel electrodes are utilized for special purporses.
-
product
Small Cell/ Outdoor DAS Antennas
*Omni, Quasi-omni, Trisector, Cardioid and Bi-sector formats*Pole mounted and Stadium style antenna configuration*High band, low band and dual band models available*Integrates GPS antenna available on select models
-
product
Single Point Aluminium Load Cell
EST-6
Technopark Automation & Control
The EST-6 is a Single Point Aluminium Load Cell suitable for use on platform scales measuring 600 x 500 mm. This load cell is available in capacities 500 kg and 1000 kg.
-
product
Flow Cell Kit
EQCMT
The two blocks of the EQCMT Flow cell are constructed using PEEK. It gives a high resistivity for chemical compounds.As well as QCM, these cell is reversible. With a inverted position of the blocks, it is possible to change from flow to static measurement.
-
product
Direct Burial Half Cell Reference Electrode
DB-A
Model DB-A Copper-Copper/Sulfate Reference Electrode designed for direct burial for long term monitoring of buried or earth contacting structures.
-
product
LC/MS/MS Method Package For Cell Culture Profiling Ver. 2
This Method Package enables the analysis of 125 compounds in under 20 minutes per sample. Performing analysis separately for each compound group such as amino acids and vitamins makes profiling of cell culture components very laborious, but with this method package a large number of culture medium components and secreted metabolites can be analyzed simultaneously.Compared to the previous version, several metabolites derived from amino acids, nucleic acids and the TCA cycle have been added, allowing even more comprehensive profiling information to be gathered.
-
product
Thermocouple Temperature Transmitter PC Programmable With Push Button Calibration
SEM1605/TC
The SEM1605TC is the next generation cost effective DIN rail mounted temperature transmitter from Status Instruments. It has been designed to accept most common Thermocouple temperature sensor inputs
-
product
Low Profile Compression Only Load Column Load Cell with Mounting
CLC SERIES
Our CLC Series is our high capacity compression only load cell, featuring low profile compact size for a wide range of portable and dedicated applications. The loading diameter (D1) is slightly convex for accurate load distribution. Low deflection through design results in ultra fast frequency response. All ranges are made from 17-4ph heat treated stainless steel and incorporate a stainless steel molded connector system designed to resist washdown and splash. The mating connector, sold separately, is available in three different cable lengths.
-
product
Handheld 2G & 3G Cell Phone Detector
SH-055UMW / 10127
This new portable Mobile Phone Detector is made for detecting 2G & 3G cellular phones (all current generations and all networks) communication in a place.
-
product
Cell Testing
PEC offers a wide range of cell testers, starting from the 5A desktop test system (ACT0505), to our range of 50A cell testers for more standardized cycling (CT0550) and our advanced cell testers with capabilities up to 4000A (ACT0550). All systems support parallel switching for achieving higher currents.
-
product
High Precision Flame-proof Compression Type Load Cell
ZR-KE
Flame-proof Compression Type Load Cell
-
product
Cell Voltage Monitor
N1200 Series
Next Generation Instrumental (Shanghai) T&C Tech. Co., Ltd.
N1200 series fuel cell voltage acquisitor is specially developed by NGI for fuel cell R&D and production. It is with compact size, high integration, high reliability and fast data transmission. N1200 standalone supports up to 200 channels. More channels can be tested simultaneously under cascade mode. Voltage acquisition range is from -2.5V to +2.5V, which completely covers the voltage range of fuel cell. Real-time voltage data of total 200 channels can be uploaded within 10ms by adopting 100M Ethernet communication. N1200 PC application software supports platform-based test applications, which allows users to customize test files based on the test requirements and process.
-
product
Calibrated Solar Reference Cell
To insure repeatable testing on any solar simulator, OAI offers 2cm x 2cm calibrated reference cells. Standard reference cell calibration cycles can be set up by OAI''s calibration laboratory to insure that your reference cell maintains certification.
-
product
8-Channel VME Strain Gauge/Load Cell Module
V385
The V385 is a VME/VXI compatible eight-channel strain-gauge signal conditioner applicable to generic bridge-type transducer applications. The V385 adds individual remote-sensed excitation supplies to each channel, increasing its precision over the V380's single excitation supply.
-
product
Single Use Cells
S.U.C.
optek Single Use Cells have an integrated conductivity sensor and enable simultaneous electrochemical and optical measurements. Various options of line sizes and connections allow for a simple integration into bioprocessing systems from low volume research up to high volume biopharmaceutical manufacturing.
-
product
Test Cell System
qCf FC25/100
The quickCONNECTfixture with an active fuel cell area of 25 cm 2 has been an integral part of our product portfolio since 2006. The excellent properties and the patented design of the cellFixture offer enormous advantages in the characterization of cell-internal components for fuel cells and electrolysis.
-
product
Solar Cell Testers
Solar Cell Testers are integrated systems incorporating Solar Simulator and I-V Measurement systems. PET offers Standard and Advance IV Measurement software. PET Cell Testers are capable of measuring a diverse range of solar cell parameters such as Isc,Voc, Imax,Vmax, Pmax, FF, Rsh, Rs and η cell conversion efficiency, complete light and dark I-V curves. All that needs to be done to test a cell is to load the cell, make electrical probes contact and press “Measure” icon on the I-V Measurement System software. The software will automatically open the Solar Simulator shutter, perform the test and close the shutter after the test is complete. The design is modular in nature and can be easily upgraded. Some options can added at a later time.
-
product
Silver Button Sockets
For BGA, QFN, or LGA applications, GTP contact technology provides >94 GHz signal speed and can additionally be used in high cycle life applications such as ATE. These sockets support pitches from 0.2 mm to 1.27 mm. Ironwood's GT sockets are ideal for prototyping and testing almost any BGA device application. These IC sockets provide excellent signal integrity yet remain cost effective. Innovative elastomer interconnect technology that delivers low signal loss (1dB at 94GHz) and supports BGA packages with pitches down to 0.2mm was utilized in these sockets. GT BGA sockets are mechanically mounted over a target system's BGA lands using mounting and alignment holes at proper locations (page 2 of the individual socket drawing shows recommended PCB layout information). These low-profile sockets are only 2.5 mm per side larger than actual IC packages (industry's smallest footprint).
-
product
In Line Load Cell (200N-5000N)
100 Series
Miniature Threaded in Line Load Cells are strain gage based transducers with temperature compensation and excellent overall performance. This type measures tensile and compressive loads up to 5000N with better than ±0.25% non-linearity.
-
product
Fuel Cells
continuously variable contact pressure ensures complete reproducibility of the test conditions ● independent of the thickness of the fuel cell components due to the self-adjusting piston and special sealing concept ● no connection and disconnection of hose- or cable connections for the exchange of cellFixture necessary ● fast &Easy clamping of the cellFixture without tools and precise exchange of the internal cell components ● maximum power density by determining the optimal contact pressure on the active cell surface ● developed for high stress in the field of quality assurance and laboratory environment
-
product
Acrylic Buttons
VAT810-TH/SD (VAT810-CO2)(VAT845
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
Desktop:Touch buttons : CO2 monitor Real-time monitoring of indoor air quality including CO2,temperature ,humudity and VOC.
-
product
Load Cell & Microvolt Meter
A high-sensitivity 5-digit meter for use with load cells, strain gauges and microvolt input signals where high accuracy and stability are required. Load cell operation allows 4- or 6-wire hookup and display in engineering units, such as lbs, kg or psi. Built-in excitation for up to four 350-ohm load cells in parallel.





























