ICP Microphones
measure acoustic frequency, time and noise levels.
-
Product
ICP Microphone System
378C01
-
This model includes a 1/4" microphone cartridge, a mated preamplifier with TEDS, and system calibration. Click the following for individual component information.
-
Product
Digital ICP® - USB Signal Conditioner
-
The Digital ICP®-USB Signal Conditioner, Model 485B39, offers plug-and-play connectivity for your measurements. Model 485B39 from The Modal Shop, a wholly owned subsidiary of PCB Piezotronics, is a pocket-sized, dual-channel ICP to USB digital signal conditioner. The unit provides any ICP sensor – accelerometers, microphones, impact hammers, laser tachometers, and more – with a digital USB output. It is truly plug-and-play, with no drivers required. Digital ICP features two BNC inputs and a 24-bit USB digital signal output, allowing a direct connection from the sensor to any PC, tablet, or smartphone device for easy data collection, analysis, and sharing on-the-go.
-
Product
ICP Microphone System
378A14
-
This model includes a 1/4" microphone cartridge, a mated preamplifier with TEDS, and system calibration.
-
Product
Microphone Preamplifier
426A11
-
1/2-inch ICP preamplifier with gain and filter switches (for prepolarized microphones)ICP(R) low noise preamplifier with gain, filters, and TEDS
-
Product
ICP Microphone System
378C10
-
This model includes a 1/4" microphone cartridge, a mated preamplifier with TEDS, and system calibration.
-
Product
ICP Microphone System
HT378B02
-
This model includes a 1/2" microphone cartridge, a mated preamplifier with TEDS, and system calibration. Click the following for individual component information.
-
Product
PROBE MICROPHONE ICP
377B26
-
Open Circuit Sensitivity (at 250 Hz)Frequency Range (+2.2/-4.9 dB)2 to 20000 HzLower Limiting Frequency (-3 dB)Inherent Noise<45 dB(A) re 20 Pa Dynamic Range(3% Distortion Limit)EnvironmentalTemperature Range (Operating)-40 to +158 F-40 to +70 C[5]
-
Product
Ultrasound Microphone
M500
-
The M500 microphone is easily used with a Windows PC/tablet/laptop to record bat calls and other ultrasonic signals with the highest quality. For recording with the M500, the BatSound Touch or BatSound Touch Lite software is used.
-
Product
USB Microphones
-
Easily used with a Windows PC/tablet/laptop to record bat calls and other ultrasonic Is esignals with the highest quality.
-
Product
Microphones
-
All these measurement microphones have a XLR connector and require a phantom power. They can be connected to specially equipped soundcards or pre-amplifiers, only.
-
Product
Microphones
-
MIC-01, MIC-02 and MIC-03 are low cost precision condenser electret microphones perfectly suited for laboratory and on-field acoustical measurements. They have identical performances but differ for their physical size; MIC-01 is preferable for fixed laboratory installations while MIC-02 is highly manageable due to its short length; MIC-03 is the best where space saving is a must. Their frequency response is individually tested against specifications and the sensitivity value is supplied. MIC-01 & MIC-02 & MIC-03 can be directly connected to your CLIO system's input.
-
Product
Microphone Interfaces
MEMS
-
Listen offers 2 MEMS digital microphone measurement interfaces from Portland Tool & Die, the laboratory-grade DCC-1448 and the low cost PQC-3048 for production line use.
-
Product
30KHZ Measurement Microphone
M30
-
Used on countless full-scale concert tours, as well as in scientific research laboratories, tropical rainforests, and rocket testing facilities, the M30 has proven to be a lab-grade audio instrument that can handle any environment.
-
Product
MEMS Microphones
-
A MEMS microphone is an electro-acoustic transducer housing a sensor (MEMS) and an application-specific integrated circuit (ASIC) in a single package.
-
Product
Microphone Preamplifier
426A30
-
1/2-inch preamplifier with 7-pin LEMO connector (for externally polarized microphones)
-
Product
Ultraminiature Microphone
MB-2200M10
-
MB-2200M10 is an ultra compact and lightweight microphone that enables measurement in narrow spaces, where have been difficult to install, without giving influence to the sound field.Its compact and lightweight features make you possible to perform measurements in a limited space, such as multi-point measurement, and measurement near the sound source. As CCLD type, the MB-2200M10 can be connected to Ono Sokki’s FFT Analyzer or CCLD supported devices.
-
Product
Multitype ICP Emission Spectrometers
ICPE-9800 Series
-
Due to their high detection sensitivity down to ppb levels, ability to analyze a broad 5 to 6-digit range of concentrations, and ability to measure multiple elements simultaneously, ICP emission spectrometers are used in a broad range of fields, such as environmental testing, pharmaceuticals, foods, chemicals, and metals. ICPE-9800 Series of simultaneous ICP atomic emission spectrometers are next-generation systems that offer the superior accuracy necessary to simultaneously and quickly analyze multiple elements regardless of their concentration levels. They also feature user-friendly software that makes analysis easy. Furthermore, the systems reduce analysis costs while providing the highest performance levels in the industry. ICPE-9800 Series systems represent the ultimate in ICP atomic emission spectrometry for environmental, pharmaceutical, food, chemical, metal, and other fields.
-
Product
Microphone Calibration Workstation
9350C
-
The Precision Acoustic Calibration Workstation Model 9350C is an accurate, turnkey, automated PC-based system that features cost-effective calibration of ¼", ½" and 1" microphone cartridges (open-circuit sensitivity), microphone cartridges with preamplifiers (closed-circuit sensitivity) and microphone Frequency Response Function.
-
Product
50KHZ MEASUREMENT MICROPHONE
M50
-
The M50 is a precision engineered 50kHz omnidirectional measurement microphone ideally suited for acoustical measurements including high-end loudspeaker design and quality control, scientific research, measurements of ultrasonic or subsonic transducers, or any application where an extremely accurate free-field measurement microphone is required.
-
Product
Industrial ICP® Strain Sensors
-
For Process Monitoring/Quality Control. The Industrial ICP® Strain Sensors incorporate piezoelectric quartz sensing crystals that respond to a longitudinal change in distance. The resultant strain measurand is an indirect measurement of stress forces acting along the structure to which the sensor is mounted. As such, these devices can provide insight into the behavior of mechanical systems or processes that generate an associated machinery reaction.
-
Product
Measurement Microphone System
MK224SYS
-
The MK224SYS Type 1 measurement microphone system offers a cost effective option to acoustic measurements. Perfomance: 8 Hz to 18 kHz response, 50 mV/Pa sensitivity and a "A" weighted noise floor less than 14 dBA.
-
Product
Microphone preamplifier
PRE-01
-
The microphone preamplifier PRE-01 has been designed to match Audiomatica’s microphones MIC-01, MIC-02 andMIC-03. It is particularly useful when the microphone has to be operated far from the analyzer or when weighted measurements are needed. PRE-01 powers the microphone connected to its input with an 8.2V phantom supplyand adds a selectable weighting filter (A or B or C); also available there is a 20 dB gain stage
-
Product
Precision Condenser Microphone
377B02
-
1/2" free-field, prepolarized condenser microphone, typical sensitivity= 50 mV/Pa (+/-1.5 dB), 3.15 Hz to 20 kHz (+/-2 dB).
-
Product
23KHZ Measurement Microphone
M23
-
The M23 is a precision engineered 23kHz omnidirectional measurement microphone ideally suited for acoustical measurements including loudspeaker design and quality control, sound system setup and troubleshooting, room acoustics, or any application where an accurate free-field measurement microphone is required.
-
Product
On-line ICP / ICP-MS Sample Preparation System
SDX ʜᴘʟᴅ
-
The SDXHPLD system combines the proven ASX‑560 autosampler with a novel vortex mixing dilution accessory. The system dilutes in the same way you do by hand: volume-to-volume dilution, using a highly accurate syringe pump. But it also goes an additional step to vortex mix the resulting dilution prior to sample introduction to ICP and ICP-MS.The SDX employs vortex mixing to promote homogenization of a sample to ensure accurate and precise analysis following dilution. The variety of sample matrices submitted for trace element analysis necessitates the need for mixing. This long overdue capability improves data quality by fully homogenizing a dilution mixture rather than performing in-line combination.The SDXHPLD is a straight-forward, fully-integrated solution for automated dilution of aqueous and acid base sample prep for ICP or ICP-MS.
-
Product
Microphone Arrays
-
One of the most important parts of an Acoustic Camera is the microphone array. It determines the spatial distribution of the acoustic microphones and therefore measurement performance of the whole system. In order to achieve the maximum possible performance in any given application, we offer a wide variety of microphone arrays. No matter if the measurement is beamforming, intensity or holography ... we have the right microphone array. For special applications we can design and build custom made microphone arrays according to the requirements of the application.
-
Product
Structural Test ICP® Accelerometers
-
Conventional structural test data systems use few to several hundred sensors. Cables bundles can be complex and confusing resulting in setup errors. Sensors with TEDS (Transducer Electronic Data Sheet) allow for an internal sensor digital chip to store sensor information. This information contains descriptive identifiers that when connected to a TEDS compatible signal conditioner or data system, reads the descriptive information and automatically aligns the data system. Human error is minimized, reducing time consuming data verification or re-test. The Series 333 ICP® accelerometers, and their accessories, are designed to address the needs of multi-point modal and structural test measurement applications. This equipment was developed in conjunction with the world renowned University of Cincinnati Structural Dynamics Research Laboratory and proven in real-world testing situations. The PCB 333 Series accelerometers delivers rapid system setup, reduces human documentation errors, maintains calibration data of each sensor, allows for “Plug-and-Play” installation, reduces overall test time lowering project test costs.
-
Product
Precision Condenser Microphone
378A12
-
1/4-inch pressure prepolarized 377A12 microphone, with 1/4-inch preamplifier 426B03 and TEDS v0.9