ICP Microphones
measure acoustic frequency, time and noise levels.
-
Product
Modern Prepolarized Precision Condenser Microphones & Preamplifiers
-
Modern prepolarized microphones are designed with newer technology than traditional externally polarized microphones. Prepolarized microphones have many advantages over the externally polarized models. They use ICP® power circuitry invented for sensors by PCB®. By applying a polymer coating to the top of the backplate and embedding a charge on it, expensive 200V power supplies can be eliminated and 2-20 mA constant current supplies or signal conditioners can be used as the power source.
-
Product
Microphone Calibration Workstation
9350C
-
The Precision Acoustic Calibration Workstation Model 9350C is an accurate, turnkey, automated PC-based system that features cost-effective calibration of ¼", ½" and 1" microphone cartridges (open-circuit sensitivity), microphone cartridges with preamplifiers (closed-circuit sensitivity) and microphone Frequency Response Function.
-
Product
ICP OES spectrometer (ICP AES)
-
SPECTRO Analytical Instruments GmbH
ICP OES spectrometer (ICP AES) for the rapid analysis of elements in a variety of matrices including aqueous, semi-conductor, petrochemical, soil, metallurgical and slurries
-
Product
Ground Isolated ICP® Pressure Sensors For High Frequency
-
PCB® Series 102B is a ground isolated version of the Series 113B. These sensors have all of the same features and benefits of the 113B Series, plus the added benefit of isolation, which helps prevent ground loop problems. This series can accommodate an optional ablative coating (Prefix: CA) to protect the diaphragm from thermal shock in flash-temperature applications.
-
Product
Industrial ICP® Strain Sensors
-
For Process Monitoring/Quality Control. The Industrial ICP® Strain Sensors incorporate piezoelectric quartz sensing crystals that respond to a longitudinal change in distance. The resultant strain measurand is an indirect measurement of stress forces acting along the structure to which the sensor is mounted. As such, these devices can provide insight into the behavior of mechanical systems or processes that generate an associated machinery reaction.
-
Product
30KHZ Measurement Microphone
M30
-
Used on countless full-scale concert tours, as well as in scientific research laboratories, tropical rainforests, and rocket testing facilities, the M30 has proven to be a lab-grade audio instrument that can handle any environment.
-
Product
50KHZ MEASUREMENT MICROPHONE
M50
-
The M50 is a precision engineered 50kHz omnidirectional measurement microphone ideally suited for acoustical measurements including high-end loudspeaker design and quality control, scientific research, measurements of ultrasonic or subsonic transducers, or any application where an extremely accurate free-field measurement microphone is required.
-
Product
IDevice Calibrated Measurement Microphone
IMM-6
-
The Dayton Audio IMM-6 is a professional-quality measurement and recording microphone that is designed to work with the entire suite of Apple “iDevices” – iPad, iPhone, and iPod. The rugged construction and compact size make it the perfect companion for audio professionals who must work on-location performing acoustic analysis, monitoring audio levels, or recording. Each IMM-6 is individually hand-calibrated using a laboratory-standard measurement microphone, for consistent, repeatable measurements that match the level of precision previously offered only by expensive stand-alone microphones.
-
Product
Electret Measurement Microphone
EMM-6
-
The EMM-6 is a precision electret condenser microphone designed for measurement and critical recording applications. The extremely flat frequency response and true omni-directional polar pattern make it perfect for use with room acoustic analyzers and audio measurement systems. The EMM-6 microphone is individually hand calibrated using a laboratory standard Brüel & Kjær microphone in conjunction with a DAAS computer measuring system. Each microphone includes stand mount, foam windscreen, transport case, and its own unique calibration response graph.
-
Product
Measurement Microphones
-
All microphones are omni-directional and 48V phantom powered. The XL2 Analyzer microphones include an electronic data sheet. The Automated Sensor Detection (ASD) of the XL2 automatically reads this data sheet, and recognizes the microphone model, sensitivity and calibration data. This ensures accurate measurement results.
-
Product
Measurement Microphones
-
The microphone bodies contain the preamplifier. They combine high dynamic range and wide frequency range with low noise. These measurement microphones connect via the ASD Cable to the XL2 Audio and Acoustic Analyzer, e.g. for measurements at remote locations or to reduce acoustic reflections.
-
Product
Precision Condenser Microphone
377B02
-
1/2" free-field, prepolarized condenser microphone, typical sensitivity= 50 mV/Pa (+/-1.5 dB), 3.15 Hz to 20 kHz (+/-2 dB).
-
Product
Sub-Miniature ICP® Pressure Sensors
-
PCB's sub-miniature 105C dynamic pressure sensors are specifically designed to fit into tight spaces where mounting space is at a premium.
-
Product
PCB High Sensitivity, 100mV/g, ICP® (IEPE) Accelerometer
780989-01
-
The PCB HSTC33 helps you acquire sound and movement data with supported PXI Sound and Vibration Modules, C Series Sound and Vibration Input Modules, and USB-based Sound and Vibration Devices. This sensor uses the Integrated Electronics Piezo-Electric (IEPE) current excitation. The PCB HSTC33 features a sensitivity range of 100 mV/g and requires a low-noise coaxial cable.
-
Product
Phantom Powered Measurement Microphone System
7052PH
-
The 7052PH Type 1.5TM phantom powered measurement microphone system offers a cost effective solution to acoustic measurements from phantom powered sources. Type 1.5TM - a superior Type 2. Frequency Response: <3 Hz to > 20kHz typ.(capsule). Sensitivity: 22 mV/Pa (-33 dBV/Pa)typ. Dynamic Range (capsule) 1% THD: <20dBA-150dBSPL (Capsule).
-
Product
Special microphones
-
G.R.A.S. Sound & Vibration A/S
Special microphones are often required for applications where there are particular requirements regarding the methods of measurements and configurations
-
Product
High Sensitivity ICP® Accelerometers
-
High sensitivity ICP® accelerometers are specifically designed to enable the detection of ultra-low-level, low-frequency vibrations associated with very large structures, foundations, and earth tremors. These sensors typically possess exceptional measurement resolution as the result of its comparatively larger size, which furnishes a stronger output signal and a lower noise floor. All units are hermetically sealed in a titanium or stainless steel housing. Models that include a 2-pin, military style connector provide the added benefit of being electrically case isolated for superior RF and EMI protection.
-
Product
HEAD artificial head microphones
HSU III
-
The HEAD-Shoulder-Unit HSU III is an artificial head microphone for binaural recordings.
-
Product
Externally Polarized Precision Condenser Microphones & Preamplifiers
-
Externally polarized microphones set the initial standard for all acoustic test and measurement applications. They rely on a dedicated 200V power supply and specialized cables with 7-pin LEMO® connectors. Their straightforward design supports a wide product range. Often chosen as replacements for existing models or when prepolarized alternatives are unavailable.
-
Product
For accurate testing of headphones, microphones telephones and loudspeakers
Artificial Mouths, Ears, and Couplers
-
Listen supplies artificial mouths, ears and ear couplers from Brüel and Kjær, GRAS and more.
-
Product
PCB High Sensitivity, 100mV/g, ICP® (IEPE) Accelerometer
784170-01
-
The PCB HSTA15 helps you acquire sound and movement data with supported PXI Sound and Vibration Modules, C Series Sound and Vibration Input Modules, and USB-based Sound and Vibration Devices. This sensor uses the Integrated Electronics Piezo-Electric (IEPE) current excitation. The PCB HSTA15 features a sensitivity range of 10 mV/g and requires a 4-socket plug-to-3 BNC plug cable.
-
Product
PCB Triaxial Accelerometer, 1000mV/g, ICP®(IEPE), 0.5Hz-3kHz
784815-01
-
The PCB Miniature Triaxial Accelerometer helps you acquire sound and movement data with supported PXI Sound and Vibration Modules, C Series Sound and Vibration Input Modules, and USB-based Sound and Vibration Devices. This sensor uses the Integrated Electronics Piezo-Electric (IEPE) current excitation. The PCB Miniature Triaxial Accelerometer features a sensitivity range of 1000 mV/g and requires the PCB lightweight cable with 4-socket plugs.
-
Product
Microphone Preamplifier
HT426E01
-
Nominal Microphone Diameter1/2Frequency Response Electrical Noise(at 22 C) (Flat 20 Hz to 20 kHz)Distortion (3 V rms input at 1 kHz)<-70 dB<-70 dB[1] EnvironmentalTemperature Range (Operating)-40 to +248 FExcitation Voltage 20 to 32 Constant Current Excitation 2 to 10 mA
-
Product
Structural Test ICP® Accelerometers
-
Conventional structural test data systems use few to several hundred sensors. Cables bundles can be complex and confusing resulting in setup errors. Sensors with TEDS (Transducer Electronic Data Sheet) allow for an internal sensor digital chip to store sensor information. This information contains descriptive identifiers that when connected to a TEDS compatible signal conditioner or data system, reads the descriptive information and automatically aligns the data system. Human error is minimized, reducing time consuming data verification or re-test. The Series 333 ICP® accelerometers, and their accessories, are designed to address the needs of multi-point modal and structural test measurement applications. This equipment was developed in conjunction with the world renowned University of Cincinnati Structural Dynamics Research Laboratory and proven in real-world testing situations. The PCB 333 Series accelerometers delivers rapid system setup, reduces human documentation errors, maintains calibration data of each sensor, allows for “Plug-and-Play” installation, reduces overall test time lowering project test costs.
-
Product
Precision Condenser Microphone
377C10
-
Performance:Nominal Microphone Diameter:1/4"CharacteristicPressure Open Circuit Sensitivity1.0 mV/Pa1.0 mV/PaFrequency Range (2 dB)4 to 70000 Hz4 to 70000 Hz Lower Limiting Frequency (-3 dB)0.25 to 3.0 Hz0.25 to 3.0 Hz Resonant Frequency (90 Phase Shift)65000 Hz65000 HzHumidity Coefficient of Sensitivity (0 to 100%, non-condensing)0.0012 dB/%RH0.0012 dB/%
-
Product
complete 1/2 inch Type 1 Measurement Microphone System
PS9200KIT
-
A complete 1/2 inch Type 1 measurement microphone system. Available in 1 Inch and 1/4 Inch versions. The heart of the KIT is the 1/2 inch Type 1 measurement microphone. A selection of 4 different 1/2 inch capsules is offered. These include models with frequency responses to 40 kHz, noise floors of 12 dBA in both free field and pressure versions. Microphone sensitivities range from 12 to 50 mV/Pa.
-
Product
Cryogenic ICP® Accelerometers
-
Cryogenic ICP® accelerometers are specifically designed to operate at temperatures below the typical -65 ºF (-54 ºC) temperature limit of most voltage mode sensors. The use of specialized, built-in, cryogenic circuitry and quartz shear sensing technology promote survivability in demanding environments such as liquid nitrogen. Each sensor is hermetically sealed and individually tested to determine the thermal coefficient of sensitivity at -320 ºF (-196 ºC) ensuring reliable operation and accurate measurements. These sensors have been successfully used in the presence of liquid helium during structural testing of rocket boosters.
-
Product
MEMS Microphone Test
-
The market is driving the need for improved voice recognition for security, automobile infotainment control, VoIP, accurate language translation, voice-activated consumer devices and high precision hearing aids. The latest next-generation microphones require highly accurate precision testing with SNR tests up to 78 dB with high parallelism, high UPH, in a high volume production environment.
-
Product
Measurement Microphone Cartridges
-
G.R.A.S. Sound & Vibration A/S
Measurement microphones are available in many types covering various frequency ranges, dynamic ranges and application situations. Selecting a microphone involves a number of choices, which can be summarized as: