Current Probes
measure AC or AC-DC amperage without contacting conductors.
See Also: Current Sensors
-
product
30 A, 10 MHz Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 3 Meter Cable
CP030-3M
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
product
Spring Probes & Hyperboloid Contacts
In-Circuit / Functional Probes, Socketless X Probes®, High Current Probes, Double Ended Probes, ATE Interface Probes, integraMate®
-
product
AC Current Probe 10 mV/A, 600A, 12 Hz LF Bandwidth, 30MHz HF Bandwidth, 1m cable
T3RC0600-HF
AC Current Probe 10 mV/A, 600A, 12 Hz LF Bandwidth, 30MHz HF Bandwidth, 1m cable.
-
product
AC Current Probe 20 mV/A, 300A, 9.2 Hz LF Bandwidth, 30MHz HF Bandwidth, 1m cable
T3RC0300-UM
AC Current Probe 20 mV/A, 300A, 9.2 Hz LF Bandwidth, 30MHz HF Bandwidth, 1m cable.
-
product
Current Probe With Hall Effect Technology
CP 35
The CP 35 current probe has been designed for use with oscilloscopes respectively for accurate, non-intrusive measurement of AC, DC and complex waveform currents.
-
product
Brute High Current Probe
P4301-2F
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
product
High Current Probes
The maximum continuous current rating of a spring probe is determined by its design, size, and construction. Typical probes are rated from 2 to 8 amps maximum continuously current at working travel. While this is sufficient for most board test applications, higher current applications will require a much more solid and rugged probe to withstand current capabilities of 10 to 150 amps and beyond.Another high current solution is our feed-through plunger probe line. As the name already describes, the plunger moves right through the probe and is made from a single piece, reducing the internal resistance of the probe to a minimum.
-
product
AC Current Probe 50 mV/A, 120A, 34 Hz LF Bandwidth, 30MHz HF Bandwidth, 1m cable
T3RC0120-UM
AC Current Probe 50 mV/A, 120A, 34 Hz LF Bandwidth, 30MHz HF Bandwidth, 1m cable.
-
product
Specialist Test Probes
High Current Test Probes, Ultra-high Current Test Probes,Kelvin Test Probes, High Frequency Test Probes, Switching Test Probes
-
product
CLAMP ON CTS
P50
Beijing GFUVE Electronics Co.,Ltd.
The P50 is a general purpose 1000A AC current probe designed for use with DMMs, loggers and other instruments that have a current input. It has a 1000:1 ratio and output of 1mA per amp or 1mV per amp measured in the jaw.
-
product
Current Probes
Tektronix current probe solutions offer:*The broadest range of AC/DC and AC-only current probes*Measurement accuracy from uAs to 2000 A*Best-in-class bandwidth up to 120 MHz*Best-in-class current clamp sensitivity down to 1 mA*The only products with 3rd Party Safety Certification (UL, CSA, ETL)*The only products with bare wire voltage ratings*Automatic readout and scaling when used with Tektronix oscilloscopes so you don’t have to convert volts to amps or manually set the scaling
-
product
N2782B AC / DC Current Probe, 50 MHz, 30 Arms
N2782B
The N2782B current probe is an accurate and reliable solution for measuring AC and DC currents. Using a hybrid technology that includes a Hall effect sensor and an AC current transformer, the probe provides accurate measurement of DC or AC currents up to 30 Arms continuous.
-
product
30A, 50 MHz High Sensitivity Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable
CP030B
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
product
Constant Current System
CCS-BTA
Vernier Software & Technology, LLC
The Constant Current System is a DC power source with a built-in current probe designed for use in electrochemistry experiments.
-
product
High Accuracy 100 Amp Current Probe
HA100
The HA100 is a compact clamp-on current probe for smaller loads where compact size is important. Its measurement range is from 0.1 to 100 amps AC and is very small which is ideal for locking inside a crowded electrical panel during monitoring.
-
product
Current Probe For Non-Intrusive Measurement Of AC, DC, And Waveform Currents
CP 305
The CP 305 current probe has been designed for use with oscilloscopes respectively for accurate, non-intrusive measurement of AC, DC and complex waveform currents.Using advanced Hall Effect technology the CP 305 can measure currents accurately up to 450A peak over the frequency range of DC to 20 kHz.
-
product
Bulk Current Monitoring Probe
MP-50
The Current Monitoring probes may be used whenever RF current measurements are required. Current measurements are made by placing a current carrying conductor within the “sensing” window of the probe and measuring the probe’s output voltage with an RF detector. Calibration of the probe permits the conversion of the voltages measured to current. Current measurements can be made over the frequency range shown in the transfer impedance curve furnished with each probe. There is virtually no loading of the circuit and the technique permits normal operation of the device under test during measurements. The MP-50 can be used for the procedure for clamp injection when the common- mode impedance requirements cannot be met given in chapter 7.4 of IEC/EN 61000-4-6 „Immunity to conducted disturbances, induced by radio frequency fields”. The MP-50 can also be used as current monitor for BCI testing as per ISO11452-4, RTCA/DO-160 section 20, MIL-STD-461 and various automotive standards.
-
product
Wide Range Flexible Current Probe
EFX6000
The EFX6000 is a flexible AC current clamp utilizing the Rogowski principle. It can be used to measure currents from 1 amp to 6000 Amps in 2 auto-ranges, over a wide frequency range to 10kHz. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas, around large conductors and where access to confined or tight spaces is a problem. It requires no batteries or external power supply.
-
product
Rogowski AC Current Probe,30 MHz, 300 A
N7042A
The Keysight N7042A Rogowski coil current probe measures AC currents up to 300 A, with bandwidth ranging from 9.2 Hz to 30 MHz. The probe has a thin, lightweight, flexible, and simple-to-use clip-around Rogowski coil that enables current measurement in the most difficult-to-reach parts and confined spaces of a circuit under test. It can also measure large AC current without an increase in transducer size.
-
product
100A, 2 MHz, DC/AC Current Probe, BNC, 100A Peak, 70A rms, 1 meter cable
T3CP100-2
100A, 2 MHz, DC/AC Current Probe, BNC, 100A Peak, 70A rms, 1 meter cable.
-
product
30A, 100MHz High Sensitivity Current Probe
CP031A
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
product
DOC Drawout Case Test Plug
The DOC Drawout Case Test Plug provides an easy way to measure current and provide test access to GE style drawout case relays and meters.The DOC features normally-closed internal contacts. Upon insertion into the case, it brings the internal drawout case contacts out for easier access. Current Measurement Probes serve to redirect current circuits without disturbing them. Disconnect pins can be used to disable specific contacts and short-circuit currents.
-
product
Complete Graphical Power Quality Analysis System
PK5064-PRO
The PK5064-PRO is a recommended choice for comprehensive power quality studies, energy audits, load studies, harmonic analysis, and more. Wide-range flexible current probes allow you to get into tight and confined spaces, wrap around large conductors, and measure almost any AC circuit that comes your way.
-
product
30 Amps, 50 MHz BW Current Probe - AC/DC , 50 Amp Peak Pulse
CP030
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
product
Standard - 22.08 (626.00) - 220.80 (6259.60) Godzilla High Current Probe
HC500F
Current Rating (Amps): 150Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 260Full Travel (mm): 6.60Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,215Overall Length (mm): 81.66
-
product
Current Probes
Any one of several techniques used to measure electric current. The measurement of current ranges from picoamps to tens of thousands of amperes.
-
product
Broadband Current Probes
Conducted currents can be measured without making direct contact with the source conductor or metallic surface by means of clamp-on broadband current probes. The BCP-5xx EMC Current Probes are designed to permit field intensity meters, spectrum analyzers, and other 50W impedance instruments to measure quantitative magnitudes of current.
-
product
Flex Clamp Meters
*Flex Clamp Current Probes expand existing meters *Compatible with most meters using universal banana leads*Flexible Coil adds accessibility - easily maneuvering around cables that are in hard to reach areas and large enough to thread around larger conductors
-
product
Current Probe
DCFlex
Power Electronic Measurments Ltd
The DCflex is an easy to use, low cost, thin and clip-around DC current probe. It is suitable for measuring large DC currents of >2kA. The DCflex takes a single shot measurement of the DC current with a typical accuracy of ±1%. It is important to understand that the DCflex does not provide a continuous measurement of DC current.