Radiometric
-
product
Photometric Radiometric Transmitters
HD2021T6 / HD2021T7
The transmitters allow converting the photometric quantity “equivalent veiling luminance” – HD2021T7 – or a photometric quantity Luminance (cd/m2) – HD2021T6 – into a current (4…20 mA) or a voltage (0…10 V) signal according to the version chosen. If the acquisition station is far from the probe (>50m), it is necessary to use the current output version.The probe is used for the control of street lighting, in particular, the measurement of equivalent veiling luminance is essential to determine the threshold luminance at the entrance of the tunnels (UNI 11095:2011).
-
product
Radiometric Probe for Photons Flow
LPPAR03… Series
The probe LPPAR03 measures the ratio between the number of photons that strike a surface in one second, in the 400 nm…700 nm spectral range and the surface area (m²). This quantity is defined as PAR: Photo-synthetically Active Radiation.
-
product
Radiometric Detectors - Research
Analyzing drug pathways, protecting lab environments, and assessing environmental contamination require instruments with the highest possible sensitivity and specificity. Radiometric detection has long been and still remains to be today, the gold standard for these applications.
-
product
Radiometric Detectors - Clinical
Designed for use in regulated environments. It comes with 5 or 10 detectors (each with 550-sample capacity), and 5 and 10 detectors (each with 1,000-sample capacity).
-
product
Radiometric Probe for UVA Irradiance
LPUVA03…Series
The LPUVA03 probe measures irradiance (W/m²) defined as the ratio between the radiant flux (W) passing through a surface and the surface area (m²) in the UVA (315 nm…400 nm) spectral range. Thanks to a new type of photodiode, LPUVA03 is blind to visible and infrared light.
-
product
Radiometric Detectors
Radiometric detectors are built by using selected, stability tested high-grade Si-photovoltaic cells. They are all equipped with individually produced and matched color glass filters. They are available in different sizes for irradiance and radiant flux measurement, both in temperature stabilized laboratory and general purpose form.
-
product
Photometric Radiometric Transmitters
HD2021T Series
The serie HD2021T allows to convert photometric and radiometric quantities, such as illuminance (Lux) and irradiance (W/m²) in the UVA, UVB, UVC spectral regions and in the 400 … 1050nm band, into a 0 …10Vdc voltage signal. The series is suitable to be installed either indoor and outdoor.
-
product
Professional Science Kit
FLIR A400/A700
FLIR A400 and A700 Science Kits offer researchers and engineers a streamlined solution for accurate temperature measurement. Simplified yet robust connections help you set up and start testing quickly; then easily view, acquire, and analyze data using included FLIR Research Studio software. The Standard kit includes a FLIR A400 or A700 Image Streaming camera, 24° lens with automatic/remote and manual focusing, as well as FLIR Macro Mode. The Professional kit has the added benefits of MSX® image enhancement, radiometric data transmission over Wi-Fi, and a close-up lens for accurate thermal measurements on small components.
-
product
USB Smart Detector
OL 731
The OL 731 USB Smart Detector is a low-cost, hand-held radiometer/photometer that can be tailored to the spectral response of the user's specific application requirements with the use of a range of sensors and filters. Several units can be multiplexed on to one USB, and it can be programmed to read in any user-specified radiometric or photometric unit. The OL 731 is suitable for a variety of critical applications.
-
product
LIXI Profiler
The LIXI Profiler uses our proprietary technology, Radiometric Profiling, the only NDT technology that allows you to see everything you need to manage a healthy pipe system without touching a thing.
-
product
Fixed-Mount Thermal Camera
FLIR Axxx-Series Image Streaming
FLIR Axxx-Series Thermal Image Streaming Cameras offer the monitoring capabilities needed to accurately detect and identify thermal issues across manufacturing and industrial processes. With multiple field-of-view choices, multi-streaming capabilities, motorized focus control, and optional compressed radiometric streaming over Wi-Fi, these fixed-mount camera solutions can tackle the most complex remote monitoring objectives. Easy configuration allows you to tailor this monitoring system to your company’s quality, productivity, maintenance, and safety needs.
-
product
Radiometric Probe for UVB Irradiance
LPUVB03BLAV
The LPUVB03BLAV probe measures global irradiance (W/m²) on a surface area (m²) in the UVB (280 nm…315 nm) spectral region. In particular, the spectral sensitivity is focused at 305 nm, with a bandwidth (FWHM) of 5 nm. The global irradiance is the result of the sum of direct solar irradiance and of diffused irradiance incident on a planar surface.
-
product
LWIR Micro Thermal Camera Module
Lepton®
The FLIR Lepton® is a radiometric-capable LWIR OEM camera solution that is smaller than a dime, fits inside a smartphone, and is one tenth the cost of traditional IR cameras. Using focal plane arrays of either 160x120 or 80x60 active pixels, Lepton easily integrates into native mobile-devices and other electronics as an IR sensor or thermal imager. The radiometric Lepton captures accurate, calibrated, and noncontact temperature data in every pixel of each image.
-
product
Site Surveys
Radiometrics Midwest Corporation
Radiometrics personnel will come to you and perform site surveys to help in the mitigation of interference or to determine if the environment contains any sources that may interfere with an individuals implanted device such as pacemakers, defibrillators, nerve stimulators, etc.
-
product
Full Range / High Resolution Field Portable NIRSpectroradiometers For Remote Sensing
SPECTRAL EVOLUTION is a leading manufacturer of field-portable and laboratory NIR spectroradiometers and spectrometers for remote sensing applications including geological remote sensing, ground-truthing, spectral remote sensing, environmental and climate research, crop and soil research, vegetative studies, forestry and canopy studies, radiometric calibration transfer, upwelling and downwelling measurement and more. Our NIR spectrometers and spectroradiometers provide the best combination of high resolution and high sensitivity resulting in the most precise field portable instruments available on the market.
-
product
Spectroradiometer
Designed to have a capability of producing any visible spectral distribution, mimicking various light sources in the visible region by feedback control of the radiant power emitted by individual LEDs. This LED test system will be used as a transfer standard for photometric, colorimetric and radiometric applications.
-
product
FCC Testing and Certification
Radiometrics Midwest Corporation
Radiometrics was one of the first labs in the country to receive acceptance by the FCC as an independent lab available for performing tests to the FCC Code of Federal Regulations.
-
product
Medical
Radiometrics Midwest Corporation
Radiometrics maintains contacts with the FDA Center for Device and Radiological heath to insure that both we and the FDA understand the unique requirements of your medical electronic device to insure a painless approval process.
-
product
SGR Scintillation Gamma Radiameter
SGR scintillation gamma radiameter serves for fast and sensitive indication of gamma-ray sources. SGR covers two basic ranges of measurements:quick and selective searching for radioactive sources with fast response, acoustic signalization and histogram of 64 measured values radiometric measurements (dose rate) with the support of point and continuous measurements.
-
product
High-Speed MWIR Science-Grade Camera
FLIR X6980™
The FLIR X6980 is an extraordinarily fast midwave IR camera designed for scientists and engineers who need to capture high-speed imagery for accurate thermal analysis and custom radiometric measurements. This thermal imaging camera combines 640 × 512 resolution with blazing-fast frame rates, allowing researchers to record stop motion on fast-moving subjects or rapid temperature changes—whether in the lab or on the test range. With a four-position motorized filter wheel and support for FLIR motorized focus lenses, the X6980 will provide higher quality recordings, save time, and mitigate frustration in dynamic acquisition environments.
-
product
ECPR System (Electrically Calibrated Pyroelectric Radiometer)
Rs-5900
Developed in conjunction with NIST, the Rs-5900 ECPR is a ±1% absolute accuracy radiometric transfer standard for the visible to near-IR (0.25-2.0µm), with the RsIR Option extending the ±1% accuracy to >20µm. The RsP-590 Pyroelectric Probe requires no cooling and maintains ±1% accuracy from 1 µW to 100 mW. The ECPR uses an auto-nulling, electrical substitution technique that allows the instrument to be referenced against NIST electrical standards, insuring maximum accuracy and precision. Unlike most electrically calibrated radiometers, there is a direct correlation between electrical and optical heating because the same material serves as both the optical absorber and electrical heating element.
-
product
PAR Quantum Radiometric Probe
LP471PAR
Quantum-radiometric probe for measuring the PHOTONS FLOW in the chlorophyll field PAR (photosynthetically Active Radiation 400nm…700 nm), μmol m-²s-¹ measure, cosine correction diffuser.
-
product
Light Meters, Detectors, UV-VIS-NIR Radiometers
Devices and systems for photometric, radiometric and colorimetric measurements of light and optical radiation. Light Meters and Radiometers for different applications like UV radiation, Laser measurements, LED measurements, photomedicine and much more.
-
product
Light Measurement Sensors
Gamma Scientific offers a catalog of professional light intensity measurement devices for photometric and radiometric applications. These devices are typically utilized by laboratories, OEM’s, value-added resellers and other groups seeking to accurately measure light intensity and brightness. Browse our light intensity measurement device catalogs to find the right photometry or radiometry solution today.
-
product
HAAS-1200 Accurate Array Spectroradiometer (Advanced Industry Grade)
HAAS-1200
Hangzhou Everfine Photo-E-Info Co., LTD
HAAS-1200 quickly and accurately measures the spectral power distribution in the range of 380nm-1000nm, and achieves the photometric, colorimetric and radiometric parameters of various luminairs and lighting sources according to the requirements of the International Commission on Lighting (CIE) standard publications.
-
product
Detector Test Bench
RTB 3000
The RTB 3000 Detector Test Bench from Santa Barbara Infrared (SBIR) is a flexible integrated IR detector test station for evaluation of single element detectors, linear arrays, and focal plane arrays. The RTB 3000 provides the radiometric stimulus necessary to perform accurate IR detector testing in both laboratory and production environments.
-
product
Spectrometers
Instrument Systems Optische Messtechnik GmbH
Optical spectrometers analyze the spectral characteristics of light radiation. Adding optical probes and absolute calibration turns this type of measurement system into a spectroradiometer. Since software is used to calculate all radiometric, photometric and colorimetric quantities from spectral data, the quality and precision of the spectrometer is extremely important. This is why Instrument Systems is dedicating most of its research and development work to this field in order to be positioned at the leading edge of technology.
-
product
UV Index Radiometric Probes
LPUVI02… Series
The radiometer LPUVI02 measures the global effective irradiance on a flat surface (Watt /m² effective), according to the requirements of the WMO for the measurement of UV-index.
-
product
On-Site Testing
Radiometrics Midwest Corporation
At Radiometrics we understand that some products are just to big to bring to us. Radiometrics will travel to you and perform in-situ testing at your facility or your clients location.
-
product
CCD Spectroradiometer
LMS-8000A/LMS-8000
LMS-8000A/LMS-8000 LED Measurement System is an automated measurement system for identifying the performance of individual LED. It is designed to have a capability of producing any visible spectral distribution, mimicking various light sources in the visible region by feedback control of the radiant power emitted by individual LEDs. This LED test system will be used as a transfer standard for photometric, colorimetric and radiometric applications.