Reference Transformers
See Also: References, Reference Standards, Reference Antennas, Reference Decoders, Reference Jumpers, Reference Sources, Reference Transmitters, Acoustical References, Frequency References, Solar Reference Cells
-
Product
Transformer Ratio Meters / TRM-101
TRM-101
-
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Produces the 3-ph or 2-ph standard power with stable voltage and phase. Fully automatic: No manual balancing
-
Product
Test Sets For Transformer Industries
-
Contemporary Test Sets For Transformer Industries are developed to recognize the potentially disastrous current transformer errors. They prevent the primary current from overpowering insulation and short circuits. They are used for developing a testing and maintenance plan for addressing the errors before any failure to save money and time. With these powerful test sets, they are sure to perform saturation testing to test the knee point of a signal by comparing primary and secondary windings.
-
Product
Attitude Heading Reference System
M&M Modules
-
PNI’s M&M modules will self adapt and learn its system and its environment automatically to provide accurate quaternions, heading, pitch and roll. All while using 100 times less power than traditional AHRS modules.
-
Product
Current And Voltage Transformer Test Set
iCT1
-
iCT1 - CT/VT Test Set is the NEW and most advanced portable equipment capable to test current, voltage and combined transformers.With the low voltage method, known as "DC method", iCT1 is able to test Current Transformers with a very high saturation voltage, up to 30 kV, in a complete safety mode. Quick and easy to use tool, iCT1 allows to perform tests in one shot without changing the connection to the CT, thanks to the integrated 5-TAP Switchbox.
-
Product
Transformer Test Equipment
-
KV Hipot Power Test Equipment Co.,Ltd
Transformer Test Equipment. Ensure that a transformer meets performance and reliability requirements, from the production line to after a repair or upgrade, when a major disruptive event occurs such as a lightning strike, or for preventive/predictive maintenance.
-
Product
IEC Current Transformer Burden
-
• Burdens of 1A and 5A for IEC & ANSI specifications are available • 40VA, 20VA, 10VA, 7.5VA, 6.25VA, 5 VA and different combinations of these at 0.8 PF 3.75, 2.5, 1.25 & 1VA at 1.0 PF
-
Product
Clamp Meters / Clamp Current Transformers
Multi-meter clamps
-
Professional electrical testing tools and accessories used to measure AC or DC current safely without disconnecting the live wire.
-
Product
Series Precision Fixed-Ratio Current Transformers
PMT25100
-
Power Measurement Technologies Inc.
Precision two-stage toroidal current transformers find application as the reference in determining the accuracy of instrumentation current transformers.
-
Product
Current Transformers
-
National Meter Industries Inc.
Is an instrument transformer, used along with measuring or protective devices, in which the secondary current is proportional to the primary current (under normal conditions of operation) and differs from it by an angle that is approximately zero.
-
Product
Fully Automatic Transformer Oil Test Set
-
1. Test as per International standards NMC insulating oil testers are fully automatic micro controller based system,completely self-contained,compact and portable giving smooth variable test voltage from 0 to 60, 80, or 100 kV for testing the dielectric strength of insulating oil in accordance with all international standards like IEC156/IS6792/ASTM D 1816/ASTM D877/ UNE 21 specifications.2. Auto mode NMC insulating oil testers are fully automatic type.1) IEC-156, IS6792, ASTM D 877, ASTM D 1816, UNE 21.2) Withstand Test A3) Withstand Test B4) 5 Minute Test5) User defined3. 100 Test results storage capacity NMC insulating oil testers has a storage capacity of 100 test results which can be recalled and printed.4. LCD display NMC insulating oil testers use LCD for easy readability of the BDV test results.5. Built in printer The printer used is a thermal paper print outs.The paper rolls can be easily installed by any person.6. User Friendly RS 232 Interface RS 232 interface is very easy to use to communicate stored data which can be saved in text format.7. Safety protection Safety interlocks are provided on the test chamber.Zero interlock protection to ensure operator safety.8. Accurate Performance The kit not only has all basic functions of an insulating oil tester but also has unique features that are seldom seen in similar products. For e.g. PROOF test A, PROOF test B, 5 Minntes test, LCD to display all test data.It ensures high work efficiency and reliability in any tough environment.
-
Product
Reference Detect Switch
RDS Series 1.5” x 1.5” x 0.6”
-
*Connectorized Package *Internal/External Reference Detect Switch *Standard Internal TCXO (±2.5 ppm) *Optional Internal OCXO (±90 ppb)
-
Product
Current Transformer Field Test Set
1043
-
The Catalog 1043 Current Transformer Field Test Set is a simple and inexpensive means whereby a current transformer installation may be quickly checked for many sources of trouble. The tests are made without interrupting the Customer's service and while the load is on.
-
Product
Current Transformer Loading Type
LCT 2
-
SHANGHAI POWOO INDUSTRY CO., LTD
- suitable for a wide range of current (1.5A~120A); - there are standard holes on the primary lead wire; therefore, can be fixed at the terminal of the electricity meters with standard bolts, which makes it both firm and convenient; - the primary lead wire is highly customer-tailored with more than 300 specifications; - encapsulated with epoxy resin to ensure strong insulation ability; - linear output current, high precision; - AMB anti-combustion plastic casing.
-
Product
Uniload Voltage Transformer Test Set
2J6
-
The Type 2J6 Knopp Uniload Voltage Transformer Test Set consists of three major parts: When the Knopp Precision Transformer in the 2J6 set is compensated for, and used with, a secondary burden of 15 volt-amperes, for example, the ratio of this precision transformer is well within 0.02% and the phase angle is well within 2 minutes. The transformer, in common with other Knopp Precision Multirange Transformers, is wound so that it has practically the same ratio and phase angle accuracy on all ranges.
-
Product
Reference Cells For PIV-IV Systems
-
NREL calibrated cell used for calibration transfer.The Abet Technologies solar reference cell is a precision instrument for the determination of solar simulator irradiance levels. The sensor is a mono-crystalline silicon solar cell having an area of2x2cm(4cm).The back of the solar cell is attached to the device in such a way that a good heat transfer to the device housing is guaranteed. Below the solar cell a Pt100 RTD temperature sensor is mounted to allow monitoring of device temperature. The device is not shunted allowing the whole IV-curve to be measured. The solar cell is protected by a high quality fused silica window, assuring spectral sensitivity over a 320 -1100 nm range.
-
Product
Micropower Voltage References
-
Analog Devices offers a broad line precision micropower voltage references with extremely low quiescent currents (series references) or minimum shunt currents (shunt voltage references). All of our precision voltage references offer excellent initial accuracy and low temperature drift over time and temperature. Our Reference Plus products combine precision voltage references with comparators or amplifiers.
-
Product
Bloomy Simulation Reference System
System
The Bloomy Simulation Reference System provides a hardware in-the-loop (HIL) test environment for dynamic, closed-loop testing of many aerospace and transportation control systems. The reference system integrates the computing, I/O, and software components needed for standalone use or to form the basis of a more complex test system.
-
Product
Step Up Transformer
MagD
-
SCOPE proudly introduces Step-Up Transformer - MagD, specially designed to cater the needs of testing of instrument Transformers. Before new systems are put into service or after any occurrence of fault, the instrument transformers need to be tested for their outputs. It is to be ensured that these instrument transformers are giving proper outputs to the protective relays. MagD is used to plot excitation curves for instrument transformers. Inbuilt voltmeter and ammeter, eliminates the need of external meters for plotting of curves. It can also be used for de-magnetization of transformer cores and also turns-ratio tests can be conducted using MagD.
-
Product
Slag & Refractory Reference Materials
-
NCS Testing Technology Co., Ltd.
Slag & Refractory Reference Materials by NCS
-
Product
Current Transformer
-
Nippen Electrical Instruments Co.
DIGITAL METERS NIPPEN electronic energy meters are panel mounting type innovative energy monitoring devices ,having state of the art electronic microcontroller circuitry for reliability and accuracy. They can be used for 1Ø / 3Ø balanced and unbalanced loads.
-
Product
G.fast Transformers
-
Our line of G.fast transformers are the preferred choice of engineers seeking the most reliable, functional isolation transformers for G.fast transmission. These compact transformers deliver excellent longitudinal balance and total harmonic distortion performance.
-
Product
Instrument Transformer & Switchgear Testing
-
Our stationary and mobile instrument transformer test systems are used to test current and voltage instrument transformers. Among other things, accuracy testing, demagnetization and insulation testing are possible.
-
Product
Current Transformer
ST-30CT
-
Standard Electric Works Co., Ltd
● 30/5A - 150/5A● 2-3V A● Class 1● Insulation 600V
-
Product
Primary Reference Generator
VCH-001
-
The Primary Reference Generator (PEG) VCH-001 is designed to generate the highest accuracy clock signals in a digital communication network. Main areas of application: – synchronization in telecommunication networks.
-
Product
Reference Magnets
-
Very stable reference magnets for highly accurate in-situ validation of magnetic field sensors, teslameters and mappers. Three Component Reference Magnet. Magnetic fields available: 100mT. Easy and fast to use. Mechanical referencing and orthogonality of the magnetic field better than 0.1° in all 3-directions.
-
Product
RF Reference Source
96040A Series
-
The 96040A RF Reference Source enables you to simplify your RF calibration system by replacing many of the instruments and accessories that make up your current system.
-
Product
Single-Phase Transformer Winding Resistance Meters
RMO-TT Series
-
RMO-TT series is perfect for measuring winding resistance of inductive objects such as power and distribution transformers or autotransformers. Additionally, every transformer resistance meter from RMO-TT series can analyze:tap changers,generators,electrical motors,high-current busbar joints,cable splices,and welding joints.Transformer demagnetization can also be performed with all RMO-TT instruments.The series is consisted of 3 models, with maximal test current from 40 A (RMO40TT) to 100 A (RMO100TT). RMO100TT is the only portable transformer resistance meter in the market with 100 A DC output current.The three independent channels enable testing of three windings in series. Consequently, a user can measure winding resistance in every tap position of an on-load tap changer without discharging between the tests.In addition to winding resistance measurement, a user can perform a detailed on-load tap changer analysis by analyzing recorded graphs (10 kHz sampling rate) and by measuring vibrations on an external tap changer tank.All RMO-TT instruments have a built-in tap changer control unit. Because of this, it is possible to remotely control on-load tap changer (OLTC) directly from the device. Also, a user can program DV-Win software to do everything automatically – running winding resistance tests and changing OLTC tap positions.The DV-Win software also enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test.All results can be exported in the report format.
-
Product
Multiple Gas Transformer DGA
TAPTRANS
-
The TAPTRANS is an 8-gas on-line transformer DGA monitoring unit designed to monitor the transformer and OLTC (On-Load Tap-Changer). The TAPTRANS can individually measure the Main, Selector and Divertor tanks in one unit. The photo-acoustic detection system used by the TAPTRANS allows measurement of high and low gas levels without the need for extensive recalibration/cleaning.
-
Product
Current Transformer Test Set
-
Vanguard Instruments Company, Inc.
The EZCT-2000C is Vanguard’s third-generation microprocessor-based current transformer test set. Designed specifically for CT testing, the EZCT-2000C has the following outstanding features that can greatly increase productivity and save time during the commissioning stage:





























