Non-contact Voltage Testers
check for presence of electricity.
-
Product
NI-9269, 100 kS/s/ch Simultaneous, ±10 V, Isolated, 4-Channel C Series Voltage Output Module
781098-02
-
100 kS/s/ch Simultaneous, ±10 V, Isolated, 4-Channel C Series Voltage Output Module - The NI‑9269 is a channel‑to‑channel isolated analog output module. The NI‑9269 adds channel‑to‑channel isolation for increased safety and improved signal quality. Channel‑to‑channel isolation is commonly needed for applications that have multiple electrical systems, such as automotive tests, or industrial applications that are subjected to increased noise and often contain multiple ground planes.
-
Product
DC-Powered, AC Voltage Monitor
VAD/VQD
-
NAI’s VAD and VQD are DC-Powered, AC Voltage Monitors used to monitor voltage characteristics of single- or three-phase power lines. This allows normal operation of system loads when the power-line characteristics are within pre-determined limits. These voltage monitors are ideally suited for rugged defense and industrial applications.
-
Product
sbRIO-9221, Non-Enclosed, ±60 V, 800 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module
781115-01
-
Non-Enclosed, ±60 V, 800 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module - The sbRIO‑9221 performs single-ended analog input. The wider voltage range makes this module well suited for industrial-level, automotive, or even smaller-cell battery measurements. There are two connector options for the sbRIO‑9221: a 36‑position spring‑terminal connector and a 37‑position DSUB connector. Non-enclosed modules are designed for OEM applications.
-
Product
NI-9263, 100 kS/s/ch Simultaneous, ±10 V, 4-Channel C Series Voltage Output Module
779012-01
-
100 kS/s/ch Simultaneous, ±10 V, 4-Channel C Series Voltage Output Module - The NI‑9263 is a simultaneously updating analog output module. It features overvoltage protection, short-circuit protection, low crosstalk, fast slew rate, high relative accuracy, and NIST‑traceable calibration. The NI‑9263 module includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity.
-
Product
sbRIO-9264, Non-Enclosed, 25 kS/s/ch Simultaneous, ±10 V, 16-Channel C Series Voltage Output Module
781119-01
-
Non-Enclosed, 25 kS/s/ch Simultaneous, ±10 V, 16-Channel C Series Voltage Output Module - The sbRIO‑9264 is a simultaneously updating analog output module that accommodates higher‑channel‑count systems. Higher density modules conserve chassis space, which leaves room for other measurement types. Each channel has its own digital‑to‑analog converter. The spring-terminal version of the sbRIO‑9264 uses a 36‑position connector for the output channels, and each channel has a ground connection. Non-enclosed modules are designed for OEM applications.
-
Product
sbRIO-9263 , Non-Enclosed, 100 kS/s/ch Simultaneous, ±10 V, 4-Channel C Series Voltage Output Module
780876-01
-
Non-Enclosed, 100 kS/s/ch Simultaneous, ±10 V, 4-Channel C Series Voltage Output Module - The sbRIO‑9263 is a simultaneously updating analog output module. It features overvoltage protection, short-circuit protection, low crosstalk, fast slew rate, high relative accuracy, and NIST‑traceable calibration. The sbRIO‑9263 module includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity. Non-enclosed modules are designed for OEM applications.
-
Product
NI-9229, ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module
779785-01
-
±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module - The NI‑9229 performs differential analog input. The NI‑9229 is an effective general-purpose analog module because of its resolution, sample rate, and input range. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating.
-
Product
NI-9262, 1 MS/s/ch Simultaneous, ±10 V, 6-Channel C Series Voltage Output Module
785503-01
-
1 MS/s/ch Simultaneous, ±10 V, 6-Channel C Series Voltage Output Module - The NI-9262 is a simultaneously updating analog output module. It features overvoltage protection, short-circuit protection, low crosstalk, fast slew rate, high relative accuracy, and NIST-traceable calibration. The NI-9262 module includes a channel-to-earth ground isolation barrier for safety and noise immunity.
-
Product
FD-11601, 8-Channel, ±10 V Powered-Sensor Voltage Input Device for FieldDAQ
786374-01
-
The FD-11601 measures up to eight channels with a voltage input range of ±10 V. Each input channel supports TEDS and provides 24 V DC to power external-powered sensors without additional power supplies. The FD-11601 features 24-bit resolution, simultaneous sample rates up to 100 kS/s/ch, and channel-to-channel isolation. It is IP65/IP67 rated to be dust-tight and water-submersible, operates in -40 °C to 85 °C environments, and can sustain 100 g shock and 10 g vibration. The FD-11601 incorporates Time Sensitive Networking (TSN) and features an integrated network switch and built-in power circuitry for simple daisy chaining. You program the FD-11601 with NI-DAQmx, which automatically synchronizes multiple FieldDAQ™ devices. The FD-11601 is ideal for test cell and outdoor environments.
-
Product
MXE EMI Test Receiver, 3 Hz to 44 GHz
N9038B
-
The Keysight N9038B is a standards-compliant MXE EMI test receiver and diagnostic signal analyzer built on an upgradeable platform. You choose the frequency coverage you need to fully test devices with outstanding accuracy and sensitivity across required ranges.
-
Product
NI-9244, 400 Vrms L-N, 800 Vrms L-L, 50 kS/s/ch, 24-Bit, 3-Phase C Series Voltage Input Module
783106-01
-
400 Vrms L-N, 800 Vrms L-L, 50 kS/s/ch, 24-Bit, 3-Phase C Series Voltage Input Module - The NI‑9244 performs single-ended analog input. The wide measurement range makes it ideal for high-voltage measurement applications such as phasor measurements, power metering, power quality monitoring, industrial machinery, and motor test. You can also perform transient and harmonic analysis with high-speed simultaneous sampling. The NI‑9244 offers three channels, so you can connect single‑ or three‑phase measurement configurations such as WYE and delta. You can incorporate the NI‑9244 into systems to meet standards such as IEC 61010‑1, C37.90 and C37.60, IEC 60255‑22‑(1:7), IEC 60255‑1, C37.188 Class M and P, EMC section of IEC 60870, EMC sections of IEC 61850, IEC 61000‑4‑30 Class S, and IEC 61000‑4‑7.
-
Product
64 Gbaud High-performance BERT
M8040A
-
The Keysight M8040A is a highly integrated BERT for physical layer characterization and compliance testing. With support for PAM-4 and NRZ signals and data rates up to 64 Gbaud (corresponds to 128 Gbit/s) it covers all flavors of 200 and 400 GbE standards.
-
Product
120 GBd High-performance BERT
M8050A
-
The Keysight M8050A high-performance bit error ratio tester (BERT) enables accurate characterization of receivers used in next-generation data center networks and server interfaces. With uncompromised signal integrity, support for NRZ, PAM4, PAM6, and PAM8 signals, and data rates up to 120 GBd, the flexible architecture of the M8050A supports 1.6T pathfinding as well as other leading-edge technologies.
-
Product
NI-9205, ±10 V, 250 kS/s, 16-Bit, 32-Channel C Series Voltage Input Module
780173-01
-
±10 V, 250 kS/s, 16-Bit, 32-Channel C Series Voltage Input Module - The NI‑9205 performs single-ended or differential analog inputs, with four programmable input ranges for each. It is an effective combination of channel count and speed at a low price for an economical multifunction system. You can choose from four programmable input ranges. To protect against signal transients, the NI‑9205 includes up to 60 V of overvoltage protection between input channels and common. In addition, the NI‑9205 also includes a channel-to-earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range. It is rated for 1,000 Vrms transient overvoltage protection.
-
Product
REM-11100, 2-, 3-, 4-Wire, 4-Channel Voltage Input Module for Remote I/O
784748-01
-
2-, 3-, 4-Wire, 4-Channel Voltage Input Module for Remote I/O - The REM‑11100 is a voltage input module for remote I/O. Remote I/O systems are low-cost, modular systems for simple machine control and measurements. A remote I/O system consists of an EtherCAT bus coupler and individual modules mounted on a DIN rail. You control the REM‑11100 from a real-time controller, such as a CompactRIO Controller or an Industrial Controller. You can use remote I/O hardware to add low-cost I/O for simple tasks while your controller handles advanced tasks such as image processing, motion control, and high-speed or specialty measurements. This module features 2‑, 3‑, and 4‑wire spring terminal connection methods, a built-in power supply for sensors, four selectable input ranges, and simultaneous sampling.
-
Product
NI-9215, ±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module
779011-01
-
±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9215 performs differential analog input. The module contains NIST-traceable calibration, a channel‑to‑earth ground double isolation barrier for safety and noise immunity, and high common-mode voltage range. It is also offered in two connectivity variants: 10‑position screw terminal or BNC.
-
Product
NI-9221, ±60 V, 800 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module
779014-01
-
±60 V, 800 kS/s, 12-Bit, 8-Channel C Series Voltage Input Module - The NI‑9221 performs single-ended analog input. The wider voltage range makes this module well suited for industrial-level, automotive, or even smaller-cell battery measurements. There are two connector options for the NI‑9221: a 36‑position spring‑terminal connector and a 37-position D‑SUB connector.
-
Product
ABex PXI to Analog Bus Bridge with Digital IOs
ABex AM-300 Controller
-
The ABex system controller ABex AM-300 is required to control the analog bus of a ABex chassis. It is used as an interconnection bridge between PXI and ABex backplane.In addition it features a whole bunch of additional functionality. Despite the 96 open drain outputs it has galvanically isolated IOs, and communication interfaces.
-
Product
Hoist Tester
-
The system has the capability of operating hyraulic powered hoists, DC powered hoists and 400Hz AC powered hoists. When a unit is connected to the system it is automatically detected and the system will load the unit's control software, acceptance procedures and operational safety limits. By doing all of this the operator does not need to worry about anything other than installing the unit and clicking Run to execute a full test procedure.
-
Product
sbRIO-9215, Non-Enclosed, ±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module
781029-01
-
Non-Enclosed, ±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The sbRIO‑9215 performs differential analog input. The sbRIO‑9215 contains NIST‑traceable calibration, a channel‑to‑earth ground double isolation barrier for safety and noise immunity, and high common-mode voltage range. Non-enclosed modules are designed for OEM applications.
-
Product
NI-9239 , ±10 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module
782402-01
-
±10 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9239 performs differential analog input. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating. Designed for both speed and accuracy, the NI‑9239 is an effective general-purpose analog module because of its resolution, sample rate, and input range.
-
Product
Non-Contact Voltage Detector
VOLTCHEK
-
The VOLTCHEK is a variable non-contact voltage detector, A proximity device which detects the presence of an alternating electric or electromagnetic field. It is used by industry professionals for live or dead voltage determination of outdoor overhead or underground at URD test points. Firstly as a proximity device to determine live or dead situations and then as a touch device to verify the source has physically reached the zero AC field. This is the only equipment capable of testing all voltage from AC 415V to 765kV from a distance, beyond arcing zone.
-
Product
Automated Coherent Receiver Tester
CoRx Tester.
-
Quantifi Photonics’ CoRx Tester provides automated measurement of key coherent receiver performance parameters. The CoRx Tester is comprised of a pre-configured PXI chassis, a two-channel tunable laser, a polarization controller, and a two-channel Variable Optical Attenuator (VOA) with built-in power meter. Just connect the two optical outputs to your Integrated Coherent Receiver (ICR), connect your ICR to the oscilloscope and let the CoRx Tester software do all the rest.
-
Product
Gearbox Tester
-
The gearbox tester was designed to test the Azimuth Drive Unit (ADU) for a missile launcher. The ADU is the horizontal position controller for the launcher. It consists of a main drive shaft, a manual drive shaft and an output drive shaft. This system uses a multi-axis motion controller to operate.
-
Product
Voltage Tester
-
*Simple and user friendly*Check 1.2V - 230V AC & 12V DC directly*Check ground line and phase line and breakpoint of the AC directly*No battery is required
-
Product
NI-9228 , ±60 V, 1 kS/s/ch, 24-Bit, Simultaneous Input, 8-Channel C Series Voltage Input Module
783861-02
-
±60 V, 1 kS/s/ch, 24-Bit, Simultaneous Input, 8-Channel C Series Voltage Input Module - The NI‑9228 performs differential analog input. With channel-to-channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. The NI‑9228 is simultaneous sampling with two options for filtering: a low-latency filter or a 50/60 Hz rejection filter. The low-latency filter enables users to use this module in industrial or control applications while getting better external noise rejection.
-
Product
NI-9229, ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module
779785-02
-
±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module - The NI‑9229 performs differential analog input. The NI‑9229 is an effective general-purpose analog module because of its resolution, sample rate, and input range. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating.
-
Product
sbRIO-9229 , Non-Enclosed, ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module
780874-01
-
Non-Enclosed, ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The sbRIO‑9229 performs differential analog input. The sbRIO‑9229 is an effective general-purpose analog module because of its resolution, sample rate, and input range. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating. Non-enclosed modules are designed for OEM applications.
-
Product
NI-9206, ±10 V, 250 kS/s, 16-Bit, 32-Channel, 60 VDC Isolation C Series Voltage Input Module
779526-01
-
±10 V, 250 kS/s, 16-Bit, 32-Channel, 60 VDC Isolation C Series Voltage Input Module - The NI‑9206 performs differential analog input with four programmable input ranges. The module provides up to 600 VDC (400 VDC in Europe) channel‑to‑earth ground isolation, making the module ideal for accurately monitoring large fuel cell and battery stacks. By referencing the module common (COM) to the middle of the NI‑9206 bank, you can measure 16 consecutive cells and remain within 10 V of the module COM.





























