Filter Results By:

Products

Applications

Manufacturers

RS232

A standard interface for serial binary data interchange defining voltage levels for logical one and logical zero, standard transmission speed and connector types.

See Also: Serial Communications, I2C, RS422, RS485


Showing results: 796 - 810 of 938 items found.

  • Battery Analyzer

    KT-97C - KILTER ELECTRONIC CO.,LTD

    ● Battery ImpedanceRange: 60mΩ / 600mΩ / 6 Ω / 60Ω (auto-range)Accuracy: ±1.0% of reading ±3digits Resolution: 0.01mΩ● DCV Range: 6V / 60V (auto-range) Accuracy: ±0.8% of reading ±3digits Resolution: 0.001V●StorageCan storage 50 groups data (impedance and voltage) and veryconvenient for you to number the batteries for detection.●Connect to PC RS-232 interface ● Display impedance and voltage of battery together. ●Supplied with lithium batteries, it is very convenient to test outdoors and indoors.Application:● Measure the impedance of any type battery which voltage below 60V,identify the capability of batteries.●A perfect tool for batteries used in vehicle, emergency lighting, alarm,sprinkler systems, UPS devices, business security and any systemusing batteries to provide power, especially for lead-acid battery used in vehicle,electromotion car etc..

  • 3-CH RTD Input Module

    ND-6013 - ADLINK Technology Inc.

    ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.

  • 15-CH Isolated Digital Output Module

    ND-6056 - ADLINK Technology Inc.

    ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.

  • Audio Fiber Tracer

    CFT-810 - FiberPro

    Motorized Polarization Controller. In addition to its basic function of adjusting polarization states in multi channels, it also provides convenient ‘save and recall’ functions. As a Scanning PC, it provides very powerful ‘auto scan’ modes with variable scanning speeds. Polarization states can be manipulated by either manual adjustment or remote control (GPIB, RS-232) using two quarter-wave plates in each channel of the PC1600. Additionally, the auto scan mode of FIBERPRO’s Motorized Polarization Controller has been upgraded in LPC, and it shows another auto scan mode of four quarter-waveplates with higher polarization extinction ratio when connecting two channels at a high speed. PC1600 is an essential tool to complete fiber-optic, multi-channel measurement systems such as WDM/DWDM as well as R&D (i.e. PMD experiments), and manufacturing.

  • Battery Monitoring System

    iPQMS-C128 - Eagle Eye Power Solutions

    The iPQMS is the premier battery monitoring system in Eagle Eye's IBwatch-Series. It ensures backup power systems are optimally maintained in large-scale environments. The iPQMS is the main processing unit that measures up to 448 jars (or 448 cells) utilizing up to seven Relaying Units (RU). Each RU connects up to 64 jars (or 64 cells) and captures data from these batteries and sends it to the MPU in real-time. The iPQMS can be used over a private network via TCP/IP, or locally with RS-232. Networked systems can utilize SMS/Email alerts during an alarm outbreak. If you do not wish to use our Battery Management Software, Modbus protocol is available for third-party integration. Flexible expanding solutions allow multiple iPQMS units to monitor all your systems in real-time.

  • 8-CH Analog Input Module

    ND-6017 - ADLINK Technology Inc.

    ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.

  • Battery Monitoring System

    IPQMS-C64 - Eagle Eye Power Solutions

    The iPQMS is the premier battery monitoring system in Eagle Eye's IBwatch-Series. It ensures backup power systems are optimally maintained in large-scale environments. The iPQMS is the main processing unit that measures up to 448 jars (or 448 cells) utilizing up to seven Relaying Units (RU). Each RU connects up to 64 jars (or 64 cells) and captures data from these batteries and sends it to the MPU in real-time. The iPQMS can be used over a private network via TCP/IP, or locally with RS-232. Networked systems can utilize SMS/Email alerts during an alarm outbreak. If you do not wish to use our Battery Management Software, Modbus protocol is available for third-party integration. Flexible expanding solutions allow multiple iPQMS units to monitor all your systems in real-time.

  • 8-CH Relay Output Module

    ND-6063 - ADLINK Technology Inc.

    ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.

  • RS-422/RS-485 Repeater

    ND-6510 - ADLINK Technology Inc.

    ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.

  • Relay Output & Digital Input Module

    ND-6060 - ADLINK Technology Inc.

    ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.

  • RISC-based DIN-rail Fanless Embedded System With I.MX 6UL Processor, COM, LAN, DIO (2-in/2-out), 4 AI Channels (16-bit, 100 S/s) And 2 PCIe Mini Card Slots

    IRU151 - Axiomtek Co., Ltd.

    The IRU151 is powered by the low-power NXP i.MX 6 UltraLite processer. They can withstand an extended operating temperature range of -40°C to +70°C and up to 2G of vibration for operating in harsh environments. Furthermore, it supports NI LabVIEW to allow users to design graphical user interfaces for their measurement applications quickly and efficiently. In order to provide data collection and device control, the IRU151 comes with various I/O connectors, including four analog input (AI) channels, one isolated RS-232/422/485 port, one isolated LAN and one isolated DIO (2-in/2-out). The four analog input channels have differential input configuration and overvoltage protection of 55V DC. The IRU151 is capable of reading analog voltages at 100 samples per second with a 16-bit resolution.

  • USB to RS-422/RS-485 Converter

    ND-6530 - ADLINK Technology Inc.

    ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.

  • Multiplex Optical Maintenance Meter

    LS280 - Lisun Electronics Inc.

    LS280 is used to measure optical maintenance factor for high power LEDs, LED module, LED bulb or other LED luminaries. It is the important measuring equipment for performing the reliability of illuminants. • Freely set the time interval and time extent for automatic measurement • LCD Display, connect with PC via RS232 and English version software. • The test results can export Excel or PDF format and easy to compare. It can be saved by LS280 software or by USB directly. • The engineer can do LED life analysis based on the LS280 test results. • LS280 worked with High Power LED Aging Test (LS600), Multiplex LED Temperature Test (TMP-8/TMP-16) and High and Low Temperature & Humidity Chamber (GDJS-*B), it can do Flux VS Temperature VS Time, which is a perfect instrument system to meet LM-80 request.

  • Multi-channel DC Electronic Load

    IT8700 Series - I-TECH Electronic Co., Ltd

    IT8700 series programmable DC electronic load adopts removable modules design, supports up to 16 channels with mainframe extension transient mode up to 25 kHz, which improves your test efficiency, with high resolution and accuracy. Users can freely choose in the 8 load modules according to the number of channels and power requirements, controlled by mainframe control panel, or controlled by host computer software via built-in LAN / RS232 /USB / GPIB interface. IT8700 is with adjustable slope, list function, automatic test and other functions, and can be applied to multiple or single output AC/ DC, DC / DC power converters, chargers and other power supply electronic components performance test, also can be used in ATE test system, solar cells, LED, communications testing, aerospace and other fields.

  • Transceiver Module

    Mornsun Guangzhou Science & Technology

    MORNSUN transceiver modules include integrated high efficiency CAN, RS485, RS232 isolated transceiver module, protocol conversion module and serial port to ethernet transceiver module. These industrial bus transceiver with DIP, SMD, SOIC and DFN optional packages features compact size, surge and ESD bus protection, a maximum isolation voltage up to 5,000 VDC and a wide operating temperature range of -40°C to 85°C, even up to 105°C, etc. Coupled with the use of IC integrated technology,  the isolated transceiver module can easily be embedded in the user's end equipment, and achieve fully-functional bus network connectivity and data communication. Check out these isolated transceiver modules with a reasonable price along with high performance and we hope that they are an ideal fit for your application needs.

Get Help