Filter Results By:

Products

Applications

Manufacturers

Showing results: 781 - 795 of 853 items found.

  • Digital Portable Panel Meters

    ST-2001 ACV - Standard Electric Works Co., Ltd

    ● Big-size LCD (112 x 59mm)● Backlight function.● Analog scale with Bar-graph for viewing. (100 bars)● 10000 counts (high resolution).● DCV Ranges: 99.99mV~999.9V (ST-2001 DCV). ● ACV Ranges: 99.99mV~800.0V (ST-2001 ACV). ● 5 manual ranges controlled by rotary switch.● Data Hold function● Low battery indication● 9V power supply● Best resolution of 0.01mV (10uV)● Precision meter for factory maintenance, field servicing and educational purposes.● With an optical USB to RS-232 data transmission cable. (DCV-R & ACV-R)● 2 optical LEDs are built-in for data transfer. (DCV-R & ACV-R)● Well isolated to contact. (DCV-R & ACV-R)● The software is included (Compact disc). (DCV-R & ACV-R)

  • Analogue (1kV below) Insulation Tester

    2132 IN - Standard Electric Works Co., Ltd

    ● High quality Taut Band movement.● Three insulation test voltages(DC) : 250V, 500V, 1000V.● Two continuity test on low ohms : 3Ω & 500Ω.● Compact and lightweight.● 200mA continuity short circuit current.● 1mA test current on insulation test at nominal voltage.● Automatic discharge of capacitive and inductive circuit with charge stored in the circuit under test. ● Live warning and display or external voltage presence.● Fuse, air gap, crowbar and overload protected.● On line battery monitoring shows if battery is ok.● Manual zero ohm adjustment.● Low battery consumption.● Mirror scale.● Push and turn locking switch for continuous and hand free testing.● BS 16 edition.

  • Digital Portable Panel Meters

    ST-2001 DCV - Standard Electric Works Co., Ltd

    ● Big-size LCD (112 x 59mm)● Backlight function.● Analog scale with Bar-graph for viewing. (100 bars)● 10000 counts (high resolution).● DCV Ranges: 99.99mV~999.9V (ST-2001 DCV). ● ACV Ranges: 99.99mV~800.0V (ST-2001 ACV). ● 5 manual ranges controlled by rotary switch.● Data Hold function● Low battery indication● 9V power supply● Best resolution of 0.01mV (10uV)● Precision meter for factory maintenance, field servicing and educational purposes.● With an optical USB to RS-232 data transmission cable. (DCV-R & ACV-R)● 2 optical LEDs are built-in for data transfer. (DCV-R & ACV-R)● Well isolated to contact. (DCV-R & ACV-R)● The software is included (Compact disc). (DCV-R & ACV-R)

  • Analogue (1kV below) Insulation Tester

    1832 IN - Standard Electric Works Co., Ltd

    ● High quality Taut Band movement.● Three insulation test voltages(DC) : 250V, 500V, 1000V.● Two continuity test on low ohms : 3Ω & 500Ω.● Compact and lightweight.● 200mA continuity short circuit current.● 1mA test current on insulation test at nominal voltage.● Automatic discharge of capacitive and inductive circuit with charge stored in the circuit under test.● Live warning and display or external voltage presence.● Fuse, air gap, crowbar and overload protected.● On line battery monitoring shows if battery is ok.● Manual zero ohm adjustment.● Low battery consumption.● Mirror scale.● Push and turn locking switch for continuous and hand free testing.● BS 16 edition.

  • DC Power Supplies

    Scientech Technologies Pvt. Ltd.

    Power Supply is the most indispensable component of any electronic laboratory. A reliable, most accurate, fully specified, guaranteed and an efficient Power Supply Equipment are thus manufactured on a large scale by Scientech Technologies which has robust output protection and fault detection capabilities. DC Power Supplies with Different specifications of Voltage and Current are being manufactured for various Applications. The DC power supply converts the conventional 110 V or 220 V alternating voltage into continuous pulsating DC voltage (+3.3 V, +5 V, +12 V and -12V) used by various electronic components. A DC Power Supply also regulates the voltage to eliminate spikes and surges common in most electrical systems.

  • MEMS Module

    COMSOL, Inc.

    The design and modeling of microelectromechanical systems (MEMS) is a unique engineering discipline. At small length scales, the design of resonators, gyroscopes, accelerometers, and actuators must consider the effects of several physical phenomena in their operation. Consequently, COMSOL Multiphysics is ideally suited for MEMS applications. To this end, the MEMS Module provides predefined user interfaces with associated modeling tools, referred to as physics interfaces, for a variety of coupled physics, including electromagnetic-structure, thermal-structure, or fluid-structure interactions. You can include a variety of damping phenomena in your model: thin-film gas damping, anisotropic loss-factors for solid and piezo materials, anchor damping, and thermoelastic damping. For elastic vibrations and waves, perfectly matched layers (PMLs) provide state-of-the-art absorption of outgoing elastic energy.

  • High Speed-Large Current DC Electronic Load (CC/CV/CR/CP)

    PLZ-4WL Series - Kikusui Electronics Corp.

    While the PLZ-4WL series succeeds to the superior operability of our conventional model of the PLZ-4W series, the PLZ-4WL series realizes the high speed rise and fall time (slew rate of 50A/µs.) in the range of low voltage with large current. The PLZ-4WL offers six operation modes, and equips with various features such as sequence operation, switching operation, soft-start function, and time and voltage measurement. The PLZ-4WL applies not only for the conventional load test of the CPU power supply, but also it can be applied to even faster current response test. In addition, the PLZ-4WL is a space-saving design (about 50% less volume of the conventional model) that can save the facility space of the testing site, and it can be applied for the single cell testing of the large scale rechargeable battery.

  • Image Analysis & Stage Micrometers

    Applied Image, Inc.

    The APPLIED IMAGE series of Image Analysis and Stage micrometers are ideally suited for calibrating optical, imaging, video, and reticle-based measurement systems. Designed for ease of use and manufactured for durability, the SM Series has both English and Metric scales in one or two axis configurations. Both types of micrometers come with NIST traceable calibration standards and are available on multiples substrates to perfectly fit your needs. The experience APPLIED IMAGE has in manufacturing precision imaged optical components makes us the trusted source for standards for magnification system microscopy and vision applications. Should you need to alter feature patterns, size, or substrate, fill out our Custom Optical Components and Standards form to start the conversation.

  • Commercial Panel Controls

    Bourns

    Panels controls are designed for applications that typically require frequent adjustment. Both rotary and slide panel control types are available. A selection of elements includes carbon, cermet, and conductive plastic. These devices are available in various sizes and shaft/bushing combinations. Some models are available with a rotary switch and seal options.Typical applications include audio mixing consoles, test and measurement equipment, consumer electronics, and medical equipment.Turns-counting dials are designed for use with precision rotary potentiometers or other types of panel controls where a turns-indicating device or an adjustment setting/locking device is needed.These devices are available to fit various shaft sizes in digital or concentric scale (analog) readout options. Typical applications include power supplies, oscilloscopes, medical equipment, and industrial automation equipment.

  • Stand Alone/ Bench Top Load Cell Amplifier/ Conditioner Module

    MODEL TMO-2A - Transducer Techniques, Inc

    The TMO-2A Transducer Modules is a complete differential amplifier/signal conditioners with self contained power. The unit provide excitation, balance and span adjustment via precision 10 turn pots, and shunt calibration necessary to couple a user supplied bridge type transducer to an indicating instrument. Zero to full scale output is specified at 4-20 mA. The TMO-2A provides a floating shunt calibration circuit which applies calibration at the transducer, thereby eliminating errors due to line losses. The excitation supply incorporates a Wagner Ground to greatly improve Common Mode Rejection. The factory set bandwidth of the module is narrow to improve stability. The removal of a single capacitor will increase the frequency response DC to 60K Hz for dynamic data applications.

  • Automatic Asphalt Content Tester

    Atico Export

    4000g sample capacity, integrated +0.1gm accuracy weighing scale, High temperature ceramic filtration system and afterburner for accurate measurement of bitumen content in asphalt mixes. Automatic operation through user defined automatic end point detection and 24 hour start timer. User defined control of furnace chamber temperature from 200 – 650oC, Digital display and printing of test data through bright LED displays and integrated printer, Software activated mechanical door lock to prevent door from opening during test process and cutting off power from the heating elements upon opening the door. Operates on Single Phase, 220V, 50 Hz, 20 Amp and consumes less than 5000 W.

  • Measurement Software for Loudspeaker System Tuning

    Tuning-Capture - WavCapture

    Tuning-Capture is a new measurement software for loudspeaker system tuning derived from the Room-Capture. Tuning-Capture uses time-domain chirp.Tuning-Capture is low cost, intuitive software; fulfil the entrance level needs, but still ultra high resolution.Tuning-Capture is ideal for room tuning and sound reinforcement system optimization. A range of newly developed analyzing tools provides fast and accurate tuning information; delay-finder with group-delay and Cepstrum analysis, filter optimization, sound level metering with histogram etc.Much effort is put in the new user interface to reduce the need for dialog boxes and spin-boxes. These are replaced with modern mouse wheel and grab ‘n’ drag mouse based and controls. For example if you need to change the range of a graph, this is now done with the mouse wheel. Dragging the scale zoom it.

  • Analog Tank Test Kit

    4108 - M. C. Miller Company

    The voltmeter included in the kit, the “Model IA” voltmeter, is designed for ease of use by meter readers and corrosion technicians alike and the voltmeter comes with an integrated RE-5 reference electrode attached for “metallic structure-to-soil” potential difference readings. The kit also includes a special test lead that has a brass thumb screw on one end which allows the test lead to substitute for the RE-5 reference electrode. This substitution allows the voltmeter to take “structure-to-structure” potential difference readings. The voltmeter offers a 0 - 2VDC range with a 10MΩ input impedance and the analog display presents a color divided scale for convenient indication as to whether or not a carbon-steel structure is receiving a suitable level of cathodic protection, with respect to the accepted 0.85V (850mV) threshold value.

  • Camera Module

    XM Bond HR - Viscom AG

    Viscom AG offers the new XM Bond HR camera module for dependable inspection of wire bonds. Its characteristics include a 21 mm x 21 mm field of view size and exceptionally fine detail resolution. It is ideally suited for the most precise inspection of thin wires in the production line. With the new XM Bond HR camera module, Viscom advances the configuration possibilities in wire bond inspection for higher in-line inspection quality. This module is particularly recommended for safety-relevant electronics, where thin wires with diameters of e.g. only 20 µm are installed. Products of this kind find use, among others, in various types of signal processing in the automotive and aerospace sectors. The high-quality optical components and sensor chips with first-class resolution and sensitivity achieve superb image quality and sharp detail resolution. Together with its 21 mm x 21 mm field of view size, the XM Bond HR offers a resolution of 4.5 µm per pixel. A telecentric lens ensures that regardless of the distance to an object, an inspection window has the same image scale; for example, the end points of an inspected thin wire are always located at the same positions in the inspection window. In addition, the telecentric optics also prevent areas on the electronic assembly next to tall components from being hidden.

  • Powder Brake Dynamometers

    PB Series - Magtrol Inc.

    The Powder Brake Dynamometer (PB Series) contains, as its name suggests, a magnetic powder. The electrical current passing through the coil generates a magnetic field, which changes the property of the powder, thus producing a smooth braking torque through friction. They are ideal for applications operating in the low to middle speed range or when operating in the middle to high torque range. Like Hysteresis Brakes, Powder Brakes provide full torque at zero speed. Like the Eddy-Current Brake Dynamometers, the PB series are water-cooled, allowing for power ratings up to 48 kW. The PB Dynamometers have accuracy ratings of 0.3% to 0.5% full scale ( 2% for PB 2.7), depending on size and system configuration. Additional mounting possibilities include speed pickup and OEM version IS.

Get Help