Showing results: 676 - 690 of 859 items found.
-
Extech PT300-SD -
Extech Instruments Corporation
The Extech PT300-SD captures pressure measurements on hydraulic, pneumatic, air compressor, and process gas systems, as well as other industrial components. The PT300-SD features linearized current output (4 to 20 mA DC), a 6.4 mm (0.25 in) NPT port connector with PS 6.4 mm adapter, and 1% full scale accuracy. The unit is made of corrosion-resistant stainless steel and requires a 9-30 VDC power source.
-
Extech PT30-SD -
Extech Instruments Corporation
The Extech PT30-SD captures pressure measurements on hydraulic, pneumatic, air compressor, and process gas systems, as well as other industrial components. The PT30-SD features linearized current output (4 to 20 mA DC), a 6.4 mm (0.25 in) NPT port connector with a PS 6.4 mm adapter, and 1% full scale accuracy. The unit is made of corrosion-resistant stainless steel and requires a 9-30 VDC power source.
-
P368 -
Validyne Engineering
The Validyne model P368 is a digital differential pressure transmitter designed for high line pressures and industrial pressure measurement applications. Full scale ranges of 8 psid to 10,000 psid are available. The on-board microprocessor provides high accuracy and improved stability in changing thermal environments. Communication via RS485, USB or CanBus provides remote zero and span adjustment as well as digital pressure readings in engineering units.
-
HFM-301 / HFC-303 -
Teledyne OEM Solutions
The HFM-301 / HFC-303 meters and controllers have flow ranges from 0-25 slm to flows of 0-1000 slm; provide analog outputs, are constructed of stainless steel and have normally closed valves. The full scale range is specified by the end user. A NIST traceable calibration certificate is standard. With a choice of elastomers and high pressure options, the HFM-301 / HFC-303 services a wide variety of applications. Cleaning for oxygen service is available.
-
NEOSEM TECHNOLOGY INC
The Neosem’s SSD test system combines advanced SSDtest hardware, software and environmental chamber into a single platform and supports all popular storage interfaces including PCIe, SAS & SATA and fast emerging protocols such as NVMe and AHCI. The SSD test system of Neosem is available ranging from desktop sized desktop sizedconfigurations for engineering use to manufcturing scale test systems for mass production with multiple burn-in chambers.
-
R1L-C -
TEGAM Inc.
The Model R1L-C is a Ground Resistance Ohmmeter designed to measure grounding system resistance as well as soil resistivity, over ranges from 2 to 20 k full scale. These resistance measurements correspond to soil resistivity from as low as 2 -cm to as high as 600,000 -cm. The R1L-C is capable of Wenner, Fall of Potential, 62% methods as well as bond and continuity measurements. Two, three and four are standard for this instrument.
-
HFM-301 / HFC-303 -
Teledyne Hastings Instruments
The HFM-301 / HFC-303 meters and controllers have flow ranges from 0-25 slm to flows of 0-1000 slm; provide analog outputs, are constructed of stainless steel and have normally closed valves. The full scale range is specified by the end user. A NIST traceable calibration certificate is standard. With a choice of elastomers and high pressure options, the HFM-301 / HFC-303 services a wide variety of applications. Cleaning for oxygen service is available.
-
LA-1 HC -
Walter G. Legge Company Inc.
LA-1 HC Floor Conductivity Tester Hand Crank is an easy-to-use meter developed for accurately testing the conductivity of floors and equipment. The LA- 1 must be used regularly to monitor proper conductivity with NFPA code # 99. Regular use of the LA-1 will establish and maintain procedures for the proper maintenance of conductive floors, eliminate fire hazards, and provide a static free environment. A hand crank AC type generator provides a rectified DC test potential. Additionally, there are no brushes to wear out. The LA-1 has an easy-to-read scale that is selectively expanded electronically to assure accurate readings over the entire range of the instrument and the scale has a length of 3.75. This is 42% longer than typical competitive testers. The LA-1 uses 500V DC to test the resistance (in ohms) between two points. (NFPA Code #99) The meter comes ready-to-use (tin foil must be applied to bottom of weights). Simply follow the instructions for use and instantly obtain an accurate measurement. Choose electric or hand powered model.
-
NTN -
FuG Elektronik GmbH
High efficiency Short circuit proof and unlimited operation with full current in short circuit condition voltage and current regulation with automatic and sharp transition; control mode indicated by LEDs Voltage and current setting with 10-turn potentiometers with precision scale; the adjusting knob can be locked 4 digit DVM for voltage and current (for table-top models) Sense terminals for the compensation of voltage drop on the load lines. The nominal voltage always refers to the output terminals Parallel and series connection possible Suitable for inductive and capacitive loads for 700 W nominal power and higher, limitation of inrush current on switching on Interlock loop to monitor the external load and internal loop as a standard for three phase units Elapsed-hour meter as a standard for three phase units
-
MIS-A -
MULTI MEASURING INSTRUMENTS Co., Ltd.
*The single and fluorescent scale indicator for 3 ranges insulation measurements enabled easy observation. *Especially, useful when working in dark place.*Hand free and continuous measurements with custom made switch.*Safe design with built in automatic discharging function for any capacitors present in the circuit.*The voltage in the circuit can be pre-checked without any switch operation for safe insulation measurements.*Compact, light weight and heavy duty rugged case.
-
SPL SERIES -
Transducer Techniques, Inc
The SPL Series single point load cell simplifies scale designs, packaging machinery and other industrial weighing equipment. Their single point design eliminates the need for multiple load cells and summing boxes, and thus, simplifies the design and reduces the cost. All SPL Series load cells employ 100% aluminum construction and features a moisture proof sealant which also makes them suitable for damp environments.
-
Metrix
Seismic sensors provide a dynamic AC signal output in mV/g or mV/in/sec. Devices with this type of output are generally intended for connection to a stand-alone vibration monitoring system rather than general automation and control instrumentation like a PLC or DCS. Metrix offers seismic sensors with a wide variety operating temperatures, frequency responses, scale factors, case materials, connector types, mounting options, and hazardous area approvals.
-
Extech RF41 -
Extech Instruments Corporation
Refractometer measures the Propylene/Ethylene Glycol freezing point from -50 to 0°C and the Specific Gravity of battery acid from 1.11 to 1.30 and provides a quick reference of battery charge condition. Requires only 2 or 3 drops of solution for fast and accurate readings. Automatic Temperature Compensation provides repeatable measurements on an easy to read scale. Prism and lens with a simple focus adjustment. Includes carrying case and calibration screwdriver.
-
72-3105 -
Tenma
Insulation Resistance Tester Full function DMM includes AC and DC voltage measurement, plus a wide range of resistance scales designed specifically for insulation resistance measurement. It is ideal for safety and preventative maintenance work on powered tools, motors, transformers and similar devices. Large backlit 6000 count display provides at-a-glance readings via both 3-3/4 digit readout and 45 segment analog bargraph.
-
Becker Nachrichtentechnik GmbH
In large scale RF signal distribution systems such as broadcast signal distributions, several signals of radio bands have to be transmitted over longer cable distances. Due to the different frequency ranges, the signals can be transmitted via one common coaxial cable. This saves costs for the coaxial cables and their installation. With help of signal combiners, multiple signal sources can be combined broadband or frequency selective to a sum signal with low loss in level.