Filter Results By:

Products

Applications

Manufacturers

DC Sources

A highly repeatable and stable DC voltage and current source.


Showing results: 271 - 283 of 283 items found.

  • Load Cell Power Supply

    MODEL PSMR - Transducer Techniques, Inc

    The PSM-R is a self contained AC power bridge excitation supply. This device consists of a low interwinding capacitance AC transformer and a high stability adjustable linear regulator designed specifically for driving transducer bridges. DC excitation is adjustable from 4 to 15 volts output and is capable of supplying 0 to 150 mA in output current. It features remote sensing to eliminate line drop errors and very low noise. It can also be used as a high quality voltage source or reference in many applications. AC input requirements are 105 to 125 VAC at 60 Hz.

  • RCD/LOOP/PAT Testers

    Kyoritsu Electrical Instruments Works, Ltd.

    Custom microprocessor controlled for highest accuracy and reliability. 3 LEDs for checking correct wiring status. 0 and 180 degree phase angle switch permits quick tests and consistent readings. Digital read-out of tripping time. Constant current source circuitry ensures that a fluctuating mains voltage does not affect the accuracy of readings. Large custom digital display readout. Visual indication of reversed phase and neutral wiring at socket. Designed to IP54 Rating. Complies with IEC 61557 Test of a large kind of RCD''''s: Standard, Selective, AC and A (DC sensitive breakers)

  • Muzzle Velocity Radars

    MVR Series - Innovative Technical Systems

    The MVR Series of Muzzle-Velocity Radars are Doppler-CW transceivers that measure the velocity of viewed objects such as projectiles. They use phase-locked millimeter-wave transmitter-receivers along with an integrated radome-protected antenna to illuminate objects under investigation. An optical boresighting aid provides alignment assistance for the narrow radiation patterns. Reflected signals from the target are received by the antenna and mixed to produce a video output equal to the Doppler spectrum of the target. A low-noise, variable gain video amplifier can drive a 50-ohm cable up to +1 volt output. The video amplifier has a feed-forward DC offset compensation circuit that extends the Doppler frequency response from under 1 Hz to over 2 MHz. An integrated DMM and LCD display on the front panel monitors various test points within the sensor to verify proper operation. The extremely rugged design allows the MVRs to withstand high acousitic shock environments so they can be located in close proximity to the projectile source.

  • 50Hz-100kHz LCR Meter

    11022/11025 - Chroma Systems Solutions, Inc.

    0.1% basic accuracyTransformer test parameters (11025), Turns Ratio, DCR, Mutual Inductance0Hz, 60Hz, 100Hz, 120Hz, 1kHz, 10kHz, 20kHz, 40kHz, 50kHz, 100kHz test frequencies21ms measurement time (≥100Hz)Agilent 4263B LCR Meter commands compatible4 different output resistance modes selectable for non-linear inductor and capacitor measuringHigh resolution in low impedance(0.01mΩ) and high accuracy 0.3% till 100mΩ rangeAdjustable DC bias current up to 200mA (constant 25Ω) (11025)1320 Bias Current Source directly control capability0.01mΩ ~ 99.99MΩ wide measurement range (4 1/2 digits)Dual frequency function (11022 option) for automatic productionBIAS comparator functionComparator function and 8/99 bin-sorting functionPass/fail judge result for automatic productionHandler interface trigger edge (rising/falling) programmableTest signal level monitor functionStandard RS-232, GPIB, and Handler I/FOpen/short zeroing, load correctionLabView® Driver

  • Wide-range Output Programmable DC Power Supplies

    PPA1500 Series - Twintex Electronics Co., Ltd

    PPA series are high precision programmable DC power supply with auto range output, output power rated 400W, 800W and 1500W, maximum rated voltage up to 1200V. PPA series offer the widest range of output voltage and current at its rated power. One PPA power supply can cover output range of multiple power supplies. It offers powerful programming function through RS232 and RS485 intefaces, supporting SCPI and Modbus-RTU commands. And it is designed to meet both bench-top and integrated system applications. It is the most economical choice of power source to facilitate auto test and auto control.

  • Electronic DC Load, 500V, 16A, 400W

    LDH400 Series - Aim-TTi

    Versatile solution for direct testing of dc power sources and PFCsConstant current, resistance, conductance and power modesWide voltage and current range, 10 to 500V and 0 to 16A400 watts continuous dissipation at 28°C (360W at 40°C)High resolution and accuracy for level settingBuilt-in transient generator with variable slewCurrent monitor output for waveform viewingVariable drop-out voltage for battery testingHigh resolution backlit graphic LCD with soft key controlAnalogue remote control of levels and TTL control of on/off and transient switchingFront and rear input terminalsLoad inputs rated to CAT II (300V)Full bus control via USB, RS232 and LXI compliant LAN interfacesGPIB Option

  • AC / DC Electronic Loads – Benchtop Testing to Automated Test Systems

    Chroma Systems Solutions, Inc.

    Chroma is the global leader in Electronic Load manufacturing. Chroma’s AC Electronic Loads are designed for testing uninterruptible power supplies(UPS), Off-Grid Inverters, AC sources, and other power devices such as switches, circuit breakers, fuses and connectors. Chroma’s DC Electronic Loads are used for power testing in all markets including automatic test systems, LED, power supply testing, battery testing, and fuel cell testing. Chroma loads can do it all including full current down to 0.4VDC, CZ mode, user defined waveforms, timing measurements, and 3 current ranges per load. Chroma’s electronic loads come standard with either USB or RS232 ports for control and can be configured for GPIB (IEEE-488) control as well.

  • 24-Bit High-Resolution Dynamic Signal Acquisition and Generation Module

    PCI-9527L - ADLINK Technology Inc.

    The PCI-9527L is a high-performance, 2-CH analog input and 2-CH analog output dynamic signal acquisition board. This board is specifically designed for audio testing, acoustic measurement, and vibration analysis applications.The ADLINK PCI-9527L features two 24-bit simultaneous sampling analog input channels. The 24-bit sigma-delta ADC provides a sampling rate up to 216 KS/s at high resolutions, making it ideal for higher bandwidth dynamic signal measurements. The sampling rate can be adjusted by setting the onboard DDS clock source to an appropriate frequency. All channels are sampled simultaneously and accept an input range from ±40 V to ±0.316 V. The PCI-9527L analog input supports software selectable AC or DC coupling and 4 mA bias current for integrated electronic piezoelectric (IEPE) sensors.

  • Three-Phase Transformer Demagnetizer

    DEM60C - IBEKO Power AB

    After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores. The best way to eliminate this source of potential problems is to use demagnetizer on the power or instrument transformer.The DEM60C is a fully automatic test instrument which performs three-phase transformer demagnetization. Transformer magnetic core demagnetization requires the application of AC current with magnitude decreasing to zero. DEM60C provides this AC current by internally changing the polarity of a controlled DC current. During the demagnetization process, the instrument supplies the current at decreasing magnitude for each step, following a proprietary algorithm. It can demagnetize single-phase and three-phase power transformers.The instrument can be connected to all three phases of a power transformer to be demagnetized, on either the primary or the secondary side. If a user selects specific vector diagrams for different types of transformers, DEM60C will run a specific demagnetization procedure for each transformer type (i.e., single phase, delta, wye/star, zig-zag.) without switching the test leads.DEM60C enables safe and efficient power transformer demagnetization. The instrument automatically regulates the injection of current and discharging energy from the inductance. During and after the operation, an intrinsically safe discharge circuit with an indicator rapidly dissipates the stored magnetic energy. The discharging circuit is independent of the power supply, which improves its reliability in case of loss of power.Test currents of up to 60 A DC enable efficient demagnetization of even the largest power transformers. Using a DV Win software, it is possible to control DEM60C externally.

  • Coil Analyzers & Power Supplies

    IBEKO Power AB

    Coil analyzers and power supply units are portable and lightweight devices intended for use in harsh switchyard and industrial environments. The typical application is switchgear and circuit breaker testing when substation battery is not connected or available. An advantage over substation battery is enabled testing in under-voltage and over-voltage conditions. Furthermore, the stable voltage outputs with a very low ripple (<0,5%) enable an analysis of the coil and motor current graphs recorded with circuit breaker analyzers from different vendors.SAT40AD, POB30AD, and POB40AD are unique devices in the market due to their dual purpose:Power supply for coils and spring-charging motorsTesting circuit breaker’s coils, motor, and auxiliary circuitAll DV Power coil analyzers and power supply units have four separate outputs for opening and closing coils.SAT40AD has two powerful motor outputs (AC and DC) which can withstand up to 40 A inrush current.POB30AD and POB40AD have DC motor output rated up to 30 A and 40 A respectively. With the use of motor outputs, POB and SAT can also be used as a power source or a temporary battery charger.SAT40A II series instruments can be controlled via PC. The DV-Win application software is used to control both SAT and CAT (Circuit Breaker Analyzers & Timers) devices at the same time, making a unique test system for switchgear and circuit breaker testing.

  • Bidirectional Programmable DC Power Supply

    IT6000C Series - I-TECH Electronic Co., Ltd

    The bi-directional programmable DC power supply of IT6000C series combines two devices in one: a power supply (source) and an electronic load (sink) with energy recovery. Based on these two functions, IT6000C offers the functionalityof two-quadrant operation. The regenerative capability enables the energyconsumed to be put back onto the grid cleanly, saving costs from energyconsumption and cooling, while not interfering with the grid. IT6000C seriesprovide 7 voltage grades, max. output voltage up to 2250V, support master-slaveparalleling with averaging current distribution, max. output power up to1.152MW. Built-in waveform generator supports generating arbitrary waveforms,and import LIST files for waveforms via front panel USB port. IT6000C is thecombination of high reliability, high efficient setting, safe and multiplemeasurement functions. IT6000C is a family of bi-directional, regenerativepower system with excellent performance, extensively used in aspects of highpower battery, automotive electronics, green energy, high speed testing etc.

  • Radiation Microdosimeters

    Teledyne Defense Electronics

    Teledyne e2v HiRel Microdosimeter is a compact hybrid microcircuit which directly measures total ionizing dose (TID) absorbed by an internal silicon test mass. The test mass simulates silicon die of integrated circuits on-board a host spacecraft in critical mission payloads and subsystems. By accurately measuring the energy absorbed from electrons, protons, and gamma rays, an estimate of the dose absorbed by other electronic devices on the same vehicle can be made. The Microdosimeter can operate from a wide range of input voltages. The accumulated dose is presented to three dc linear outputs and one pseudo-logarithmic output giving a dose resolution of 14 µrads and a measurement range up to 40 krads. These outputs are intended to be directly connected to most analog-to-digital converters (ADCs) or spacecraft housekeeping analog inputs (0-5 V range), which makes minimal demands on the host vehicle. The Microdosimeter incorporates a test function to allow electrical testing of the hybrid without the need for a radiation source.

  • Electrical Safety Test Equipment

    IBEKO Power AB

    Making a product “safe” requires an understanding of “hazards” that exist in each electrical product. Electrical shock is one of the four fundamental hazards. Because of that, it must be a part of any product electrical safety evaluation. Even though a product requires an electrical power source and uses electrical or electronic components, it should not present an electrical shock hazard to the user.Ground bond or earth continuity testing prevents electrical shock hazards. Similarly to a fault to earth, test instruments generate a high current. The standard requires that the resistance between protective earth and any conductive surface on the equipment does not exceed 0,1 Ohm. The test is performed by applying a DC current between the conductive surface and protective earth. By measuring the voltage drop, it calculates the resistance.RMO-E instruments are ideal for testing the protective bonding (grounding) of equipment following the standard IEC 61010-1. Applying current up to the value of 100 A and the ability to provide in the Contin menu (continuous operation) test current for the pre-set test duration (equal or exceeding 1 min) gives a user a possibility to easily check the protective bonding/grounding of the equipment. The full load voltage of 12 V assures proper measurement and accurate result. Finally, an instrument displays pass/fail classification according to user-preset parameters.

Get Help