Electromagnetic
See Also: Electromagnet, Energy, Electromagnetic Simulation
-
Product
Shielding Effectiveness/ Conductivity Test
EM-2107A | 30 MHz – 1.5 GHz
-
The EM-2107A is a standard test fixture for evaluation of the electromagnetic shielding effectiveness of planar material. The fixture is an enlarged section of coaxial transmission line and complies fully with the requirements of ASTM test method D4935-1. The measured data relates to the shielding effectiveness due to a plane wave (far field EM wave) from which near field values for magnetic and electric fields may be inferred. The EM-2107A is provided with a reference standard test specimen, a dynamic range specimen. Dynamic range of greater than 80dB is achievable, although the cables and other test system components usually establishes the limiting factors.
-
Product
EMC Testing Inductors
-
Electromagnetic Compatibility (EMC) testing is a somewhat unique discipline within the world of electrical product development and analysis. Electromagnetic Compatibility (EMC) testing is primarily concerned with understanding and mitigating the affects of Electromagnetic Interference (EMI).
-
Product
Electromagnetic Interference Test
-
Electromagnetic interference (also known as radio frequency interference) tests are used to determine the electromagnetic characteristics of electrical, electronic, and electro-mechanical equipment. Electromagnetic interference, both radiated or conducted, can affect the performance of equipment. Electromagnetic interference tests are specified as follows: conducted emission, radiated emission, conducted susceptibility, and radiated susceptibility.
-
Product
Field Strength Meters
FIM-22 And FIM-41
-
The Models FIM-22 and FIM-41 are portable field strength meters designed to provide precise, direct measurements of electro-magnetic fields in the 200 kHz to 5.0 MHz spectrum. These units include a receiver, integral shielded loop antenna, precision attenuator, internal calibration source, and battery power supply. With calibration accuracy traceable to the National Institute of Standards and Technology, the FIM-22 and FIM-41 meet the most exacting requirements of government and industry. Their hinged covers, on the rugged drawn aluminum cases, contain a loop antenna. Opening the cover to a vertical position connects the antenna terminals to the receiver via maintenance-free gold-plated contacts. An interlock switch prevents inadvertent battery discharge when the cover is closed.
-
Product
TERAHERTZ HOT ELECTRON BOLOMETER DETECTORS FROM 0.1 to 70 THz
-
Insight Product Company offers ultrafast superconducting hot-electron bolometers (HEBs) operating at terahertz frequency range. from 0.1 to 70 THz. Superconducting hot electron bolometers HEBs are designed to detect and register the electromagnetic radiation pulses in the frequency range from 0.1 THz to 70 THz.
-
Product
AC+DC Power Sources/Amplifiers
-
The N4A range of AC+DC Power Sources are available with a variety of output power ratings from 6kVA up to and above 30kVA. They are the perfect solution for general power source applications as well as IEC61000 electromagnetic compatibility standards testing, offering low THD and excellent reliability.
-
Product
3D Guidance®
-
The 3D Guidance® electromagnetic tracking solution delivers exceptional performance and value for OEM image-guided interventional and therapy systems and medical trainers that require real-time navigation tracking capabilities. The 3D Guidance solution tracks 6DOF sensors that can be embedded into OEM instruments such as ultrasound probes, rigid and flexible scopes, and laparoscopic tools. Continuous in-vivo tracking is maintained through difficult anatomy, even when sensors are out of sight. Low latency and fast update rates ensure the most subtle tool movements are instantly tracked and visualized within the OEM host interface. The 3D Guidance solution is available in the driveBAY™ and trakSTAR™ configurations, as based on the Electronics Unit. The trakSTAR is a standalone desktop unit that connects to a direct power source. The smaller driveBAY fits inside the drive bay of a computer, OEM imaging cart, or medical trainer/simulator, using the host’s power supply. Both share the same tracking accuracy and reliability. The ready-to-use configuration facilitates cost-effective integration and speeds time to market.
-
Product
Radiation (EMF, Nuclear, RF)
-
Sper Scientific radiation meters measure EMF, Nuclear, and Microwave radiation levels. Whether you are, measuring the RF strength of Wi-Fi and LAN network, or the electromagnetic field emissions from electrical power lines and transmission equipment, computers, HVAC, audio/video, and other electrical appliances. Our meters are small and light enough to go anywhere, yet sensitive enough to detect minuscule amounts of gamma, beta or X-rays.
-
Product
Near-Field Probes 100 kHz up to 50 MHz
LF1 set
-
The LF1 near-field probe set consists of 4 shielded near-field probes used during the development process for emission measurement of longwave, medium wave, and shortwave frequencies on electronic devices. The probe heads of the LF1 set are designed for incremental detection of sources of electromagnetic interference on assemblies. First, the electromagnetic interference of the assembly is detected by the LF-R 400 probe from up to 10 cm. Then probes with higher resolution like the LF-B 3, LF-U 5 and LF-U 2.5 are used to more precisely detect any source of interference. The probe heads are designed for taking measurements at single pins and larger components. Near-field probes are small and handy. They have a current attenuating sheath and, therefore, are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. The H-field probes do not have an internal terminating resistance of 50 Ω.
-
Product
Insulation Resistance Meter
AMIC-15k1
-
The partial discharge indicator PDI. Diagnosis of insulation systems based on standard measurements of IR, DAR, PI, SV, RT, DD. Allows to test the electrical durability of the tested object - indication of breaking voltage. The high resistance to electromagnetic interference ensures uninterrupted operation in power plants and near high-voltage transmission lines up to 1200 kV AC and 500 kV DC.
-
Product
ESD Event Detector
Novx MiniPulse
-
Simco-Ion's Novx MiniPulse ESD Event Detector is designed for tool and process monitoring. This affordable, small footprint embeddable monitor has been developed to warn of product damage risks at the point of electrostatic discharge. The MiniPulse uses time domain and threshold discrimination to detect pulse electromagnetic energy. Through the use of specific antenna configurations and placement, the MiniPulse can provide ESD event detection for well-defined small areas.
-
Product
EMC/EMI Testing
-
NCEE Labs has state of the art test equipment and experienced iNARTE EMC/EMI and qualified staff to provide Electromagnetic Compatibility (EMC) and Electromagnetic Interference (EMI) testing. The lab maintains accreditation to the latest FCC, CE and other international EMC/EMI standards.
-
Product
ITA, i1, EMI Shielded, With Protective Cover
410128102
ITA
The i1 EMI has many of the standard features of the i1, in addition to Electro-Magnetic Interference (EMI) protection. The EMI shielding effect on the i1 EMI ITA is provided by the stainless steel fibers in the removable plastic cover and threaded metal coupling adapter.
-
Product
Electro Magnetic Meter
-
This meter is used to indicate radiated electromagnetic fields. Wherever there is a voltageor a current, electric (E) and magnetic (H) fields arise.
-
Product
Infraded Temperature Transmitter
Model KM 6816-4 / KM 6816-5
-
Kusam Electrical Industries Limited
With CE approval and protection against electromagnetic disturbance for EU standard
-
Product
Concrete Moisture Meter
Model KM 917
-
Kusam Electrical Industries Limited
This is precision instrument adopting HF electromagnetic waves to measure the moisture content ratio without damaging the object under test. It can be set depending on different building material to raise its measurement accuracy.
-
Product
Gauss Meters
-
A gauss meter displays electromagnetic wave measurements in Gauss (G), milliGauss (mG), milliTesla (mT) or microTesla (µT) units. A gauss meter can detect either static (DC) permanent (rare-earth) magnetic or dynamic (AC) electromagnetic fields (EMFs), or both. Thus, it is important to review the specifications of a gauss meter prior to purchase to ensure suitability for the intended application.Neodymium (NdFeB) permanent magnets are among the world's strongest and most widely used magnets. When testing magnets made of neodymium or other rare-earth elements, a gaussmeter or magnetometer capable of measuring DC magnetic fields is required. However, most electromagnetic fields encountered are generated by AC currents. Examples include electrical power lines, transformers and wiring for overhead lighting, solar panels and other electrical devices and equipment. Electromagnetic fields from electrical installations are believed to cause feelings of nervousness, anxiety and paranoia in EMF-sensitive human beings.Most gaussmeters offered by PCE Instruments can be calibrated and certified according to DIN ISO 9000 standards for an additional fee. Replacement gaussmeter probes and optional accessories are available for most gaussmeter models.
-
Product
Brushless Resolvers
-
Computer Conversions Corporation
Computer Conversions GT transducers are brushless, Electromagnetic, Rotary Sensors used to provide Precise Absolute or Incremental Position, and Velocity feedback in harsh environments. All Computer Conversions Transducers are continuous rotation, bi-directional, and electronically passive devices (no electronic components to degrade or fail), that require zero maintenance, and may be installed in virtually inaccessible locations.
-
Product
RED Directive Testing & Certification
-
The Radio and Telecommunications Terminal Equipment Directive (R&TTE Directive 1999/5/EC) has been in place in the EU for many years serving radio and telecoms technology. To accommodate developments in radio equipment technology and to align with the requirements of the New Legislative Framework (NLF), the EU R&TTE Directive has been re-written. As of 2016, the European Commission replaced the R&TTE Directive with the Radio Equipment Directive (RED), which establishes safety and electromagnetic compatibility (EMC) requirements for equipment using the radio spectrum. Following June 13, 2017, after a one year transition, the RED 2014/35/EU replaced the R&TTE Directive. All new and existing products within the scope of the RED must comply in order to achieve CE marking.
-
Product
Electromagnetic Radiation Tester
KM 196
-
Kusam Electrical Industries Limited
Unit : Electric Field : V/m; Magnetic Field : mT. Precision : Electric Field : 1V/m; Magnetic Field : 0.01 mT. Range : Electric Field : 1V/m ~ 1999V/m. Magnetic Field : 0.01 mT ~ 19.99 mT. Alarm Threshold : Electric Field : 40V/m, Magnetic Field : 0.4 mT. Reading Display : 3½ Digit Digital LCD display with Backlight. Frequency Range : 5Hz ~ 3500MHZ. Sampling Time : About 0.4 second. Measuring Mode : Dual Mode. Overload Alert : “1” appears on LCD. Sound & Light Alarm. Data Hold function. Auto Power Off. Average & Peak measurement. Low Battery Indication. Operating Temperature & Humidity : 0°C ~ 50°C; below 80%RH. Power battery : 9V Battery. Dimension : 63.6 x 31 x 125.8mm. Weight : Approx. 146g.
-
Product
Electromagnetic Radiation Analyzer
SEM-600
-
Beijing KeHuan Century EMC Technology Co,.LTD
Broadband Electromagnetic Radiation Analyzer SEM-600 can accurately measure various complex electromagnetic environments. The probe covers all frequencies from low frequency to microwave radiation. It can measure electric field strength and magnetic field by equipping different types of probes. Intensity (magnetic induction) and power density, it is also equipped with ordinary probes and other weighted probes based on human safety standards.
-
Product
Magnetic Testing Instruments
-
Yuxiang Magnetic Material Ind. Co., Ltd.
Magnetic Testing Instruments for testing electromagnets and automatic hysteresigraph
-
Product
Whole Body EM Phantoms
EM - PHANTOM
-
Schmid & Partner Engineering AG
The POsable Phantom for Electromagnetic sYstems Evaluations (POPEYE) is an anatomically correct human phantom based on a torso shell w/ head with posable arms, hands and legs. This radio frequency (RF) human has been designed to meet the requirements for test configurations for which the effects of the body on the EM performance cannot be neglected, such as operating tablet and laptop computers and other body-mounted transmitters. With a simple adjustment (one tightening screw), the arms, hands and legs can be positioned accordingly for conducting simulations of any usage or operation (standing, sitting, arms raised, talking position, etc...).
-
Product
Inductive Heater
BD-1.01
-
The device is assigned to heat the bars to the state, which allows upsetting. The DB-1.01 heater characterizes especially high watt-hour efficiency (bigger than 98%) thanks to suitable concentration of electromagnetic field in the heating zone of inductor (the solution secured by patent). It is possible to addapt the nductive heater BD-1.01 for heating any others bars.
-
Product
SAFEONE® Pro Personal RF Safety Monitor
Pro SI-1100XT
-
SafeOne® Pro SI-1100XT is an effective and economical means to monitor the strength of electromagnetic (RF) fields from mobile phone towers, microwave ovens, radio and television installations, high frequency welders, and other common workplace RF sources between 10 and 18,000 MHz. The Personal RF Monitor is an important tool in complying with FCC, OSHA, and other safe workplace requirements.
-
Product
EMR Testing
-
It is widely accepted that exposure of the human body to high levels of Electromagnetic Radiation (EMR), Electromagnetic Energy (EME) or Electromagnetic Fields (EMF) may lead to adverse health effects. To ensure the protection of personnel in the workplace and to protect members of the general public, it is essential that the EMR levels comply with relevant exposure limits set by regulators in each country.
-
Product
Radiation Detectors
-
A radiation detector is a device for measuring nuclear, electromagnetic or light radiation. A nuclear radiation detector identifies nuclear radiation by measuring the emission of ionizing radiation of alpha particles, beta particles and gamma rays. Also referred to as a geiger counter, a nuclear radiation detector consists of two main elements: the processing electronics and the geiger tube. The geiger tube is filled with low-pressure inert gas like helium, argon or neon. If radioactive radiation occurs, the inert gas is ionized. An anode within the geiger tube registers the quantity of ionized particles numerically correlating with the strength of the radioactive radiation. The radioactivity measurement is then displayed on the LCD screen of the geiger counter or nuclear radiation detector.
-
Product
Electromagnetic Environment Simulators
A2PATS® Products
Simulator
Our A2PATS Family of Products are electromagnetic environment simulators built upon Textron Systems' open-architecture direct digital synthesizer technology, coupled with our proven user interface. Our easily programmable, plug-and-play modular architecture uses identical, phase-coherent, direct digital Synthetic Stimulus Instruments (SSIs) as the radio frequency (RF) source for all signals. These modular commercial RF Sources are easily configured in our commercial cabinets. Four standard configurations are available including single-cabinet, multi-cabinet, mini-A2PATS, and A2DSG™.The A2PATS Family consists of numerous commercial products including but not limited to A2PATS, A2DRI™, A2DSG and A2EOSTIM.
-
Product
AS-Interface Power Supplies and Monitors
-
*High noise immunity and electromagnetic compatibility*Wide input voltage range*Excellent short-circuit and overload protection*Excellent power reserve*Robust metal housing for secure mounting