Calibration
maintains accuracy of test asset by correcting out of specification conditions.
See Also: Calibrators, Power Calibration, Display Calibration, Calibration Standards, Calibration Software, Calibration Services, Calibration References
-
Product
Spectrophotometer - Spectrometer
-
Spectroscopy has a wide area of application in many fields. Spectroscopy is based on the concept of Energy = frequency x Planck (E=ʎh) constant which is used to study matter. Spectrometry is the technique which is used to analyze the concentration of elements in the sample being tested. Our products are able to analyze carbon, aluminum, sulfur, gold, silver, magnesium, steel, alloys and many other elements. We can also calibrate our products to account for elements like oxygen which are present in many compounds by calibrating with a known sample.
-
Product
Electrical Calibrators
-
We offer different electrical calibrators for electrical quantities. We mainly offer products for DC signals related to process calibration, such as current, voltage, resistance and frequency.
-
Product
HIPOT Insulation Testers
-
Crown high voltage, transformer type hipot insulation testers are safe, easy to use for quick, positive determination of grounds, shorts, and broken wires in motors, transformers and other low voltage equipment or wiring systems. A turn of the selector switch gives a selection of seven voltages;500, 1080, 1250, 1500, 1750, 2000 or 2500 volts calibrated to +/- 5% accuracy; NEMA recommendation for insulation test is twice normal voltage plus 1000 volts. Since this instrument has a capacity of 2500 volts, it readily accommodates all normal requirements.
-
Product
Test and Measurement Pressure Transducer
P895
-
The P895 is designed for a wide variety of pressure measurements where high resistance to vibration and superior stability through temperature change is required. The zero and full-scale output calibrations are set by the potentiometer adjustments accessible from the top cover.
-
Product
Propeller Meters
-
Measures accurately over a flow range of 10:1 or greater.± 2% of rate accuracy, guaranteed by certified wet calibration at three test points in.Sparling’s National Institute of Standards and Technology (NIST) traceable hydraulic flow lab.Sturdy cast or fabricated steel construction.Operating temperatures are over 100° F(unless higher temperature construction is specified).Suspended solids are over 0.5% of volume.Easily maintained with standard tools.Registration can be furnished in any standard Engineering Unit.
-
Product
Automated And Connected Mobility Testing
-
The future of mobility will be highly automated. Most new vehicles already feature some sort of assistance systems and rapidly advance into more complex functionalities. But with such technological progress comes increased development effort, complexity, and time-to-market pressures. We offer a great variety of solutions for the calibration, verification, and validation of Advanced Driver Assistance System (ADAS) and Autonomous Driving (AD) features to ensure robustness, reliability, performance quality, safety, and user acceptance.
-
Product
Zero Field Cavity
-
Zero field cavities generate a zero magnetic field in an air gap. They are mainly used to calibrate hall probes for their zero scale value of output for the magnetic field strength H or the magnetic flux density B they measure. For example Gaussmeters can be calibrated by using Zero Field Cavity.
-
Product
1pps-Locking-Modules
-
This is a module to control an OCXO or Rubidium oscillator with 1PPS from a GPS receiver. The Quartzlock A6-1PPS uses a 3 state Kalman filter algorithm to measure & correct the frequency offset of the oscillator with respect to the 1PPS input. Time-tagged input 1PPS to 200ps resolution & <1ns jitter. Analog interpolator is self calibrating. Interface to GPS decodes messages & extracts relevant info. i.e. time correction data for 1PPS output, this has AVAR of the Rb or OCXO i.e. 5 x 10-12/s & <100ps RMS jitter. The output is steered to time coincidence with GPS time/UTC to 1ns resolution. Holdover initiated by 1PPS fail or data from GPS RX that 1PPS is inaccurate. During holdover, measured frequency offset & drift steer the oscillator & 1PPS is still available.
-
Product
Signal Optimizer Software
-
A unified software package for calibration, signal creation and analysis.
-
Product
Multi-channel Synchronous Receiver
SRS6000
Receiver
Many EW, SIGINT and MIMO applications begin with channel-to-channel synchronization; however, that one step can take months to achieve. The SRS6000 and its in-built auto-calibration algorithm make this a task of minutes - not months. In addition, should your cabling or setup change, the calibration routine will automatically adjust.
-
Product
PXI-6233, 16 AI (16-Bit, 250 kS/s), 2 AO, 6 DI, 4 Sinking DO, Bank-Isolated, PXI Multifunction I/O Module
779620-01
Multifunction I/O
16 AI (16-Bit, 250 kS/s), 2 AO, 6 DI, 4 Sinking DO, Bank-Isolated, PXI Multifunction I/O Module—The PXI‑6233 is a bank-isolated DAQ device designed for voltage I/O. It offers analog I/O, digital input, sinking digital output, two 32‑bit counters, and digital triggering. The digital input and outputs are compatible with 24 V signals. It combines the safety and performance benefits of isolation with high-performance timing, amplification, and calibration technologies to offer accurate measurements and precise control. The PXI‑6233 is ideal for test, measurement, control, and design applications in environments with high voltages and electrical noise. You can use the PXI‑6233 to read from encoders, flow meters, and proximity sensors as well as control valves, pumps, and relays.
-
Product
Paperless Recorders
-
Transcat is your premier provider of paperless dataloggers. We carry an extensive inventory of test & measurement equipment, with over 3000 products available for same-day shipping. For many instruments, new instrument calibration is also available, ensuring that your product is tested and ready for use as soon as you get it.
-
Product
BigRef
-
Calibrate your sun simulators with utmost precision thanks to IMT Technology’s large-scale BigRef reference cell.
-
Product
Pressure Test & Calibration Pumps
-
Pressure Test Pump is a hand operated pressure pump designed to generate pressure from 95% vacuum to 1,500psi (100bar). A high-quality screw press is designed for fine pressure adjustment, with an adjustment resolution up to 10 Pa (0.1 mbar). A specially designed shut-off valve makes the pressure as stable as possible during calibration. A built-in gas-liquid isolator protects the pump from moisture and dirt to reduce the need for maintenance. Two hand-tight quick connectors installed on the pump allow easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches. The 918 is an ideal comparison test pump for pressure instruments calibration.
-
Product
NI-9215, ±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module
779011-01
Voltage Input Module
±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9215 performs differential analog input. The module contains NIST-traceable calibration, a channel‑to‑earth ground double isolation barrier for safety and noise immunity, and high common-mode voltage range. It is also offered in two connectivity variants: 10‑position screw terminal or BNC.
-
Product
Calibration Kit
FMCK1000
-
Designed to withstand daily use in high-traffic environments such as in the testing lab or on the production floor. This cost effective calibration kit provides reliable and accurate instrument tuning for all of your test and measurement requirements. Applications: VNA, Full 2-Port CAL VNA, Thru CAL VNA, Substitution CAL method Test & Measurement Lab Equipment Accessories Engineering Test and Evaluation General Purpose Test and evaluation.
-
Product
ConFigXP
-
AMETEK Sensors, Test & Calibration
ConFigXP is free software to customize your XP2i digital pressure gauge to fit your application. You can add features and special modes, remove features to simplify the gauge, and complete password protected tasks, like calibration adjustment.
-
Product
Antenna, Octave Band Horn
EM-7021 | 2 GHz – 5 GHz
-
Electro-Metrics offers three horn antennas, each covering an octave bandwidth from 1 to 10 GHz. The horns are individually calibrated and can be used for either receiving or transmitting applications. They are especially suited to radiated immunity testing and can be used to generate fields in excess of 200 Volts/meter. All three horns feature type “N” connectors and exhibit low VSWR to ensure compatibility with power amplifiers.
-
Product
Standard Gain Horn Antenna
SAS-586
-
This Standard Gain Horn Antenna will provide reliable, repeatable measurements. An ideal solution and a standard workhorse of any EMC test house for compliance testing. Features: 12.4 GHz to 18 GHz, Individually Calibrated, FCC, MIL-STD, VDE and TEMPEST Testing.
-
Product
Microphone Measurement Capsule
TG MM1W
-
Interchangeable measurement microphone capsule for TG 1000 handheld transmittersTo calibrate ELA and PA systems in the theatre, at live concerts or at festivals
-
Product
pH & ORP Sensors
-
The Barben Analytical Performance Series products are 3rd generation combination pH/ORP electrodes targeted at harsh, industrial measurement applications. High pressures, strong chemicals, and elevated temperatures typically shorten the lifespan of conventional double-junction pH probes. In these applications the Performance Series sensor offers extended sensor lifespan, as well as decreased drift, and longer calibration intervals. Each sensor is manufactured with our patented Axial Ion Path® reference technology, proprietary Low-Noise & High-Temp Signal Cable along with proprietary ruggedized, high temp and coat resistant glass formulations. A wide selection of sensor body styles and process fittings in a variety of corrosion resistant materials allow direct replacement of short-lived OEM pH/ORP sensors. Barben Performance Series sensors are compatible with all major manufacturers of pH analyzers and transmitters. Upgrade your analytical measurement without the hassle and expense of replacing costly field instruments.
-
Product
Field-installation Type MLSS Meter (Four-Wire Transmission)
HU-200SS
-
HU-200SS connects immersion type MLSS sensor (SS-90) and measures MLSS in activated sludge. A wide range (0-2000mg/L)of SS contents can be measured with excellent reproducibility using the near-infrared radiation transmission method. Any of the calibration curves of MLSS, Clay (inorganic mud) and Kaolin may be used as standard substances of SS. If "MLSS" is selected for an activated sludge treatment tank, "Clay" for the precipitation treatment of construction sludge, or "Kaolin" for white mud, a concentration can be obtained closer to an analyzed value.
-
Product
Portable Calibration Baths
6109A / 7109A
-
The Fluke Calibration 6109A and 7109A Portable Calibration Baths are liquid baths that let process industry professionals calibrate four times more sanitary sensors per batch in less time and with twice the accuracy of other portable baths in this class. Larger than micro baths, up to four tri-clamp sanitary sensors fit easily into these baths for calibration at ± 0.1 °C temperature display accuracy. Throughput is even higher for sanitary RTDs with small or no flanges. Two bath models cover a wide temperature range: 35 °C to 250 °C for the 6109A and -25 °C to 140 °C for the 7109A. Each model offers a “-P” version that includes process electronics for connecting an external reference probe. Professionals working in clean process industries, including facilities managers, production engineers and calibration technicians, prefer these baths for a variety of reasons.
-
Product
Special Products
-
Whether your need is waveguide subsystem or custom assembly or special products such as flanges, shims, short plates, offset shorts of calibration kits, we are happy to help.
-
Product
Noise Source Test Set, 10 MHz to 26.5 GHz
N2002A
Noise Source
The N2002A noise source test set is a low cost, stand-alone instrument that, as part of a calibration system, enables fast, repeatable calibrations with minimal levels of uncertainty.
-
Product
Light / Lux Meter, Calibrated w/Data, 50000 lx, 100 lx, 4 %, 185 mm, 78 mm, 38 mm
72-7250 CAL D
-
The 72-7250 CAL D from Tenma is a digital light meter with RS232 capability. It has custom one-chip microprocessor LSI circuit which ensures high accuracy. The meter features 13mm (0.5”) super large LCD display with contrast adjustment for best viewing angle, data hold and auto power off. It records maximum, minimum and average readings with RECALL facility. The 72-7250 has RS-232 PC serial interface, user selectable lighting type (tungsten, fluorescent, sodium or mercury, daylight) and zero adjustment by push button. The meter operates from 9V battery.
-
Product
Phasor Measurement Unit Calibration System
6135A/PMUCAL
-
The 6135A/PMUCAL system is the only fully automated and traceable PMU calibration system available today. It fully complies to the IEEE C37.118.1™-2011 and section 7 of IEEE C37.242:2013 standards for PMU operation and verification.
-
Product
Low Phase Noise Reference Source
96270A
-
The 96270A RF Reference Source is the simplest, most accurate and cost-effective single instrument for calibrating spectrum analyzers and RF power sensors and more, up to 27 GHz.
-
Product
Power System Analyzer
931A
-
Model 931A, with state-of-the-art PowerDSA™ Digital Signal Analysis, make more measurements, more accurately, and at a lower price than ever before. Basic accuracy of 0.05 % of reading and 0.05 ° phase, harmonic analysis, and full three-phase capability are standard. Model 931A also incorporate full two way serial communication for use in power quality trend monitoring. The model expands usability by including transducer calibration and timer features.