Showing results: 1036 - 1050 of 1175 items found.
-
40-592A-118 -
Pickering Interfaces Ltd.
The 40-592A FIBO (Fault Insertion Break-Out) Matrix Module is a large-scale high density switching matrix based on the Pickering BRIC format. The fault insertion BRICs are designed for applications requiring the simulation of a variety of faults in complex, high pin count, applications involving sensors and control units. Typical faults that can be simulated are open-circuits, short circuits to ground or battery, or short-circuits between input/output lines. Typical applications are in automotive and aerospace industries which involve safety or mission critical systems that have to behave predictably when cabling or sensor faults occur.
-
40-592A-014 -
Pickering Interfaces Ltd.
The 40-592A FIBO (Fault Insertion Break-Out) Matrix Module is a large-scale high density switching matrix based on the Pickering BRIC format. The fault insertion BRICs are designed for applications requiring the simulation of a variety of faults in complex, high pin count, applications involving sensors and control units. Typical faults that can be simulated are open-circuits, short circuits to ground or battery, or short-circuits between input/output lines. Typical applications are in automotive and aerospace industries which involve safety or mission critical systems that have to behave predictably when cabling or sensor faults occur.
-
Extech 480172 -
Extech Instruments Corporation
This Extech 480172 Line Splitter provides a fast and easy way to “open” standard 120 Volt AC electrical lines, eliminating the need to cut off the plug and separate the conductors. When connected between a 120 Volt AC outlet and a device under test, this splitter separates the hot/live conductor from the neutral and ground, which enables users to measure AC current up to 15 Amp on a two-wire or three-wire lines using a clamp meter. This splitter also features two Voltage Test jacks so that voltage can be measured using a multimeter.
-
Laycock Systems
Crown high voltage, transformer type hipot insulation testers are safe, easy to use for quick, positive determination of grounds, shorts, and broken wires in motors, transformers and other low voltage equipment or wiring systems. A turn of the selector switch gives a selection of seven voltages; 500, 1080, 1250, 1500, 1750, 2000 or 2500 volts calibrated to +/- 5% accuracy; NEMA recommendation for insulation test is twice normal voltage plus 1000 volts. Since this instrument has a capacity of 2500 volts, it readily accommodates all normal requirements.
-
Hilkar
HRG systems limit the fault current by placing high resistance between neutral point of transformer (or generator) and ground. As it is not possible to locate the fault point in delta connected systems, an artificial neutral point is created and delta connected system can be grounded. This allows a fault current of a few amperes thus locating the fault point gets easy. When the neutral point is grounded thru high resistance, both continuity of operation is provided during fault condition and sufficient current (typically between 2 A and 10 A) flow is provided for ease of locating the fault point.
-
Esders GmbH
Highly sensitive and selective gas detection & gas measurement device withlaser technology for the inspection of underground gas pipes using suitableprobes (e. g. carpet probe). The device can also be used for the vehicle-basedpipeline inspection.With built-in diaphragm pump, Bluetooth module and rechargeable Li-Ion battery.The following applications are possible:- Inspection of underground pipes- Inspection of accessible pipes in buildings- Inspection of accessible pipes on plants, etc.- Inspection of ground soil for pinpointing (optional)- Purging of gas pipelines (optional, only in combination with pinpointing)- Gas analysis (with dual laser module)
-
779526-01 -
NI
±10 V, 250 kS/s, 16-Bit, 32-Channel, 60 VDC Isolation C Series Voltage Input Module - The NI‑9206 performs differential analog input with four programmable input ranges. The module provides up to 600 VDC (400 VDC in Europe) channel‑to‑earth ground isolation, making the module ideal for accurately monitoring large fuel cell and battery stacks. By referencing the module common (COM) to the middle of the NI‑9206 bank, you can measure 16 consecutive cells and remain within 10 V of the module COM.
-
780180-01 -
NI
±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module - The NI‑9229 performs differential analog input. The NI‑9229 is an effective general-purpose analog module because of its resolution, sample rate, and input range. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating.
-
779785-01 -
NI
±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module - The NI‑9229 performs differential analog input. The NI‑9229 is an effective general-purpose analog module because of its resolution, sample rate, and input range. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating.
-
779785-02 -
NI
±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module - The NI‑9229 performs differential analog input. The NI‑9229 is an effective general-purpose analog module because of its resolution, sample rate, and input range. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating.
-
40-204-002 -
Pickering Interfaces Ltd.
The 40-204-002 (PXI) and 42-204-002 (PXIe) are dual channel differential multiplexers designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They are available with support for 1 or 2-channels of two wire serial interfaces. Each channel pair can be looped out to external equipment or the switches can be used simulate a channel open fault. Using the fault bus, switches can simulate a short between both wires or a short to one of two externally applied fault conditions – such as battery supply or ground - via two fault buses.
-
781119-01 -
NI
Non-Enclosed, 25 kS/s/ch Simultaneous, ±10 V, 16-Channel C Series Voltage Output Module - The sbRIO‑9264 is a simultaneously updating analog output module that accommodates higher‑channel‑count systems. Higher density modules conserve chassis space, which leaves room for other measurement types. Each channel has its own digital‑to‑analog converter. The spring-terminal version of the sbRIO‑9264 uses a 36‑position connector for the output channels, and each channel has a ground connection. Non-enclosed modules are designed for OEM applications.
-
780159-02 -
NI
300 Vrms, 50 kS/s/ch, 24-Bit, Simultaneous Input, 3-Channel C Series Voltage Input Module - The NI‑9225 performs differential analog input. The wide measurement range is well suited for high-voltage measurement applications such as power metering, power quality monitoring, motor test, battery stack testing, and fuel cell tests. You can perform transient and harmonic analysis with high-speed simultaneous sampling. In addition, you can prevent ground loops and add safety to a system with 600 Vrms channel‑to‑channel isolation between the three NI‑9225 channels.
-
779522-01 -
NI
24 V to 60 V, 8 Channel (Sinking/Sourcing Input), 250 µs C Series Digital Module - The NI‑9422 works with industrial logic levels and signals to directly connect to a wide array of industrial switches, transducers, and devices. Each channel accommodates 24 V to 60 V digital input signals. The NI‑9422 features channel‑to‑channel and channel‑to‑earth ground isolation for the highest level of safety for automotive and industrial environments The NI‑9422 is a correlated digital module, so it can perform correlated operations, triggering, and synchronization.
-
M9122A -
Keysight Technologies
The M9122A is an 8x32 full crosspoint switch matrix offering high-voltage switching in a high-density PXI module. This module allows for higher voltage switching of multiple channels in a single instance. Any row can be connected to any column, making it ideal for routing instrument signals to the device under test. This module is configured with a common ground. The durable armature switches are capable of switching up to 100Vrms, with up to 60W of power. The 8-wide bus can be used to route signals between your instruments and the device under test. Choose from the durable connector block or standard cable connections.