Showing results: 481 - 495 of 1177 items found.
-
11930B -
Keysight Technologies
The Keysight 11930B limiter provides input protection for a variety of RF and microwave instrumentation. Failure mode for the limiter is either an open circuit or a short circuit to ground, thereby protecting the instrument from damage. The Keysight 11930B provides the same protection to spectrum analyzers and sources. At even greater power levels, failure mode for limiter is either an open circuit or a short circuit to ground, thereby protecting the instrument from damage.
-
EMI Stream -
NEC Informatec Systems, Ltd.
At the placement design stage, EMI Stream software examines optimal locations for parts by using actual .dsn files and verifies the effects of the proposed EMI solution. EMI Stream can analyze resonance which occurs between the power and ground planes by analyzing the resonance which occurs and changing the locations of capacitors.
-
E220-6U-1 -
VECTOR Electronics and Technology, Inc.
6U x 220mm Eurocard size for 96-pin DIN connectors. Pad-Per-Hole both sides. Voltage and ground buses around board perimeter on both sides. Pad and bus surfaces solder coated for user convenience.For solder, Wire-Wrap or mixed wiring methods. Row and column legends provided.
-
QMC Instruments Ltd
Our Multi-mesh filter technology is unique and allows extremely precise wavelength selection. It has been developed over 40 years by our astronomical academic colleagues, and is now a cornerstone technology used in all major astronomical projects in the sub-millimetre and far-Infrared region of the spectrum for both ground and space-based applications.
-
VI Control Systems Ltd.
VI Control Systems has designed several connector blocks for mating ribbon cables to screw terminals. Our design goal was to make the connector blocks small and inexpensive. Connector blocks are mounted by using 6-32 stand-offs. The connector blocks feature a ground plane that is connected to the mounting screw holes.
-
ZET 048 -
ZETLAB Company
Seismic impact control system is used to control ground surface shifts caused by earthquakes, explosions and other natural or technology-related factors. Seismic control system is used to obtain actual information of the seismic environment as well as for process facilities state monitoring (in particular, for petroleum industry pipelines systems control).
-
DCX-22 AA -
KELLER AG für Druckmesstechnik
The data collector DCX-22 AA measures and records ground water levels using KELLER's two sensor AA-technology (absolute-absolute). The submersible depth sensor measures the water level. Barometric pressure variations are measured and compensated with the built-in waterproof air pressure sensor which is mounted in the electronics housing at the top of the borehole.
-
Renice
Renice 6U VPX Computer complies with OpenVPX Vita65 specification. It adapt GPGPU architecture, on board ARM processor and compatible with industrial and rugged design on the structure. It applied in the high-performance computing center, high-performance display, parallel computing, and computing cluster application, eg Ground Radar, Airborne Radar and Shipborne Radar.
-
8012eS -
Sealevel Systems, Inc.
The 8012eS PCI Express digital interface provides eight optically isolated inputs and eight Reed relay outputs (SPST). The isolated inputs are non-polarized and rated for 3-30 VDC. Optical isolation protects the PC and other sensitive equipment from the voltage spikes and ground loop currents that are common to industrial environments.
-
8804 -
VECTOR Electronics and Technology, Inc.
100 Gold plated edge contacts (50 each side)on 0.125"(3.175mm) centers. Voltage/Ground buses. Zig-Zag buses. I/O mounting area for ribbon cable header. Row and column legends provided. S-100 Form Factor.Pin 1 and 51 committed to power. Pin 50 and 100 committed to ground.
-
T-Vlf -
IRIS Instruments
The VLF receiver is specially designed for high productivity surveys, in ground water and mining exploration. No orientation of the operator with respect to the direction of the transmitter is required since three magnetic sensors measure the components of the VLF field. Tilt or horizontality of the sensor unit is neither required since two inclinometers correct for tilted position.
-
VFL159124-036 -
Virginia Panel Corporation
Vendor Flying Lead (VFL) Cable, 160 Pin Female LFH to QuadraPaddle Leads, 28AWG Twisted Pair, 160 T/P's, SHARED GROUNDS 80 T/Ps, 168 connection points, CONN: 780009-02, VPC Contact 610138216 - QP RCV (22AWG-28AWG) (5 AMP/25 mΩ MAX), 36" length.
-
VFL159124-072 -
Virginia Panel Corporation
Vendor Flying Lead (VFL) Cable, 160 Pin Female LFH to QuadraPaddle Leads, 28AWG Twisted Pair, 160 T/P's, SHARED GROUNDS 80 T/Ps, 168 connection points, CONN: 780009-02, VPC Contact 610138216 - QP RCV (22AWG-28AWG) (5 AMP/25 mΩ MAX), 72" length.
-
VFL159124-060 -
Virginia Panel Corporation
Vendor Flying Lead (VFL) Cable, 160 Pin Female LFH to QuadraPaddle Leads, 28AWG Twisted Pair, 160 T/P's, SHARED GROUNDS 80 T/Ps, 168 connection points, CONN: 780009-02, VPC Contact 610138216 - QP RCV (22AWG-28AWG) (5 AMP/25 mΩ MAX), 60" length.
-
VFL159124-048 -
Virginia Panel Corporation
Vendor Flying Lead (VFL) Cable, 160 Pin Female LFH to QuadraPaddle Leads, 28AWG Twisted Pair, 160 T/P's, SHARED GROUNDS 80 T/Ps, 168 connection points, CONN: 780009-02, VPC Contact 610138216 - QP RCV (22AWG-28AWG) (5 AMP/25 mΩ MAX), 48" length.