Showing results: 841 - 855 of 1149 items found.
-
779136-01 -
NI
24 V, 8-Channel (Sinking Input), 100 µs C Series Digital Module - The NI‑9421 works with industrial logic levels and signals to connect directly to a wide array of industrial switches, transducers, and devices. Each channel is compatible with 24 V logic levels and has an LED indicating the state of that channel. The NI‑9421 offers isolation between the input channels and earth ground.
-
783734-01 -
NI
24 V, 8-Channel (Sinking Input), 100 µs C Series Digital Module - The NI‑9421 works with industrial logic levels and signals to connect directly to a wide array of industrial switches, transducers, and devices. Each channel is compatible with 24 V logic levels and has an LED indicating the state of that channel. The NI‑9421 offers isolation between the input channels and earth ground.
-
779136-02 -
NI
24 V, 8-Channel (Sinking Input), 100 µs C Series Digital Module - The NI‑9421 works with industrial logic levels and signals to connect directly to a wide array of industrial switches, transducers, and devices. Each channel is compatible with 24 V logic levels and has an LED indicating the state of that channel. The NI‑9421 offers isolation between the input channels and earth ground.
-
40-592A-115 -
Pickering Interfaces Ltd.
The 40-592A FIBO (Fault Insertion Break-Out) Matrix Module is a large-scale high density switching matrix based on the Pickering BRIC format. The fault insertion BRICs are designed for applications requiring the simulation of a variety of faults in complex, high pin count, applications involving sensors and control units. Typical faults that can be simulated are open-circuits, short circuits to ground or battery, or short-circuits between input/output lines.
-
40-592-121-186X8-2P -
Pickering Interfaces Ltd.
The 40-592 FIBO (Fault Insertion Break-Out) Matrix Module is a large-scale high density switching matrix based on the Pickering BRIC™ format. The fault insertion BRICs are designed for applications requiring the simulation of a variety of faults in complex, high pin count, applications involving sensors and control units. Typical faults that can be simulated are open-circuits, short-circuits to ground or battery, or short-circuits between input/output lines.
-
GFL-T + GFL-R -
Technology Products
The DC Earth Fault locator is suitable to test the DC Battery System and Trace Ground Faults. The system is suitable for Power Plants, Sub-Stations upto 765KV and other industries. The system is highly capable in tracing and pin pointing the DC earth faults in a live system without requiring any shut downs. The receiver sensitivity of 1mA and better is capable to trace most complex fault.
-
783739-01 -
NI
±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9215 performs differential analog input. The module contains NIST-traceable calibration, a channel‑to‑earth ground double isolation barrier for safety and noise immunity, and high common-mode voltage range. It is also offered in two connectivity variants: 10‑position screw terminal or BNC.
-
779138-01 -
NI
±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9215 performs differential analog input. The module contains NIST-traceable calibration, a channel‑to‑earth ground double isolation barrier for safety and noise immunity, and high common-mode voltage range. It is also offered in two connectivity variants: 10‑position screw terminal or BNC.
-
779011-01 -
NI
±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9215 performs differential analog input. The module contains NIST-traceable calibration, a channel‑to‑earth ground double isolation barrier for safety and noise immunity, and high common-mode voltage range. It is also offered in two connectivity variants: 10‑position screw terminal or BNC.
-
787814-01 -
NI
Non-Enclosed, ±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 16-Channel C Series Voltage Input Module - The sbRIO‑9220 helps you perform differential analog input. The sbRIO‑9220 contains NIST‑traceable calibration, a channel‑to‑earth ground double isolation barrier for safety and … noise immunity, and high common-mode voltage range. Non-enclosed modules are designed for OEM applications.
-
TS Model -
PJ Electronics, Inc.
Although all PJ Surge Testers are capable of testing 3 Phase Motors, this "TS" Model has the same characteristics as the Signature Model (rack-mounted, Tektronix TDS1002, 1 Billion Samples/sec, real time, programmable, storage oscilloscope) but includes a built-in 3 phase test selector switch that facilitates 3 phase motor testing by mechanically re-positioning the ground terminal.
-
NI
The C Series Voltage Input Module helps you work with voltage measurement applications. This module features isolation to separate channels from each other, from COM, or from earth ground for safety, noise immunity, and high common-mode voltage range. The module features up to 100 V of overvoltage protection for errant signal connection or unexpected outputs to the individual channels. You can use included options such as configurable input ranges, output channels, various connectors, and enclosed or non-enclosed modules.The C Series Voltage Input Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.
-
CAEN S.p.A.
- From 12 to 48 independently controllable High Voltage channels- 0 ÷ 3.5 kV output voltage- Maximum Current 3.5 mA- Either Radiall Multipin or SHV connectors- Available with either positive or negative polarity- Up to 10 nA / 500 pA current set / monitor resolution- Up to 5 mV voltage set / monitor resolution- Very Low ripple, down to < 5 mVpp- 2 different channel grounding - Common Ground (AGxxxx) - Common Floating Return (Axxxx)- Independently programmable for each channel: - Output voltage - Current limit - Ramp up/down - TRIP parameter- Current generator operation in over current condition- Specific design for High Altitudes 0÷5000 m (A7030 only)
-
T1000-15 -
Tesuto Systems
T1000-15 breakout box with dual 15 pin D-Sub connectors for signal capture or monitoring. Dual connectors provide a total of 30 test points plus a ground jack. All test points use standard size 4mm banana jacks. Test points may be connected using shorting banana cable to allow signal continuity. Ideal for continuity measurements, isolation testing, and signal capture.
-
PurePulse -
Grund Technical Solutions, Inc.
PurePulse is a flexible and efficient ESD tester for HBM, TLP, MM and HMM. Its 2-pin style setup reduces tester parasitics, it captures waveform data and can be automated to test thousands of pins without the need for a test fixture. Our PurePulse system was designed from the ground up to be customized to meet your testing needs, take a look at the features below and schedule a demo with us to learn more.