product
Single Channel USB Programmable Instrumentation Amplifier
USBPIA-S1
The USBPIA-S1 stand alone USB controllable module provides a single channel of high-quality instrumentation amplifier and optional AC coupling, for front-end signal conditioning compatible with all popular A/D converter devices. The USBPIA-S1 is powered with 9 to 12VDC so it can be connected to a battery voltage source or the supplied 115-220VAC adapter may be used for operation with wall power anywhere in the world. When programmed from the USB port, the USBPIA-S1 will remember all of the programmed properties between power cycles. Program once and operate as a stand- alone signal conditioner without having to reprogram for every use. This is perfect for turn-key applications. It's easy to connect the USBPIA-S1 into the data collection system. Input and output signals can be routed through BNC connection or using the detachable screw terminal connectors. Optional SMA type adapters are also available.
-
product
Analog Summing Amplifier
SIM980
Stanford Research Systems, Inc.
The SIM980 Summing Amplifier has four input channels that can be added or subtracted from each other. The output noise is less than 60 nV/√Hz, and crosstalk between channels is less than -80 dB. With a bandwidth of 1 MHz, a slew rate of 40 V/ms, and input offsets that are trimmed to ±100 µV, the SIM980 is extremely useful in many analog applications.
-
product
Gain Block Amplifiers
RF gain block amplifier from Pasternack is featured in our extensive in-stock RF amplifier selection. Our connectorized gain block RF amplifier uses SMA connectors. This SMA gain block amplifier has a minimum frequency of 10 MHz, a maximum frequency of 3 GHz and a typical gain of 20 dB.
-
product
Overdrive Protected Amplifier
RF Lambda’s line of overdrive protected amplifiers incorporate a technology which eliminates the need for a limiter to protect the amplifier from damage. High input powers up to 10W can be injected in the amp without damage. Hermetically sealed options are available upon request.
-
product
HF Amplifier
bsw TestSystems & Consulting AG
Whether a HF amplifier which is mounted in a 19" rack is viewed as an instrument, a system or a component largely depends on the point of view of the application developer. We list this product family here; however we would like to point out that our 19" amplifiers for rack-mount and benchtop applications, as well as modules without power supply, are listed in the "Components" section.
-
product
Current Data Logger 0-24mA
VA601-A125
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
Multi-function record meter is a new record meter designed for the actual demand of various industrial site, which integr.
-
product
RF Amplifier
SA812AGC
Hangzhou Softel Optic Co., Ltd.
SA812AGC Field Bidirectional AGC Amplifier is a new high gain amplifier. Adopt optimized circuit design and scientific and rational process. High performance AGC control circuit inside is useful for stable gain and low distortion. It's the best choice for large and medium-sized bidirectional CATV transmission network.
-
product
Headphone Amplifier
MH-8
High-power headphone amplifier that distributes the stereo input to eight headphone outputs
-
product
Dual Channel High Voltage Linear Amplifier
A800D
This unit contains two independent A800 amplifiers that share common ground reference and power supply.
-
product
Through Hole type DC Current Sensor/for Load Current Measurements
MOHT-800B Open loop method
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Hall effect measurement for DC/AC/Pulsed current.*For the use of UPS, batteries, switching power supply, DC motor drivers, etc.
-
product
Distribution Amplifiers
The Quartzlock range of distribution amplifiers are intended for use when multiple outputs from a single frequency standard/generator are required. This may be encountered in engineering labs, national standards labs, research and development, calibration labs and production. This is vital for the distribution of signals from other precision frequency standards like Hydrogen Masers, Cesium oscillators. For a technical discussion about distribution amplifiers go here or select a product range below.
-
product
Calibrator, Calibrated w/Data, Current, 185 mm, 78 mm, 38 mm
72-6694 CAL D
The 72-6694 CAL D from Tenma is a current calibrator. It provides quality and accuracy of handheld calibrator of precision current source. It features large LCD display (maximum display counts 1999, 13mm (0.5") digit size). The current calibrator has 006P DC 9V, MN1604/PP3 battery or equivalent alkaline type or heavy duty type power supply. The dimension is 185mm × 78mm × 38mm (7.3" × 3" × 1.5") and weight is 265g/0.58lb (including battery). It has adjustable 0 to 24mA current source, 2 ranges (0 to 19.99mA (0.01mA display resolution, ±(0.25% FS + 1d) accuracy), 0 to 24mA (0.1mA display resolution, ±(0.5% FS + 1d) accuracy).
-
product
2 GHz to 6 GHz, 25 W Power Amplifier Module
HMC7748
The HMC7748 is a multistage power amplifier (PA) that provides 25 W of saturated output power across the band of 2 GHz to 6 GHz. It draws 0.7 A from a 12 V supply and up to 4 A from a 28 V supply. Input signals of as much as −8 dBm are acceptable, and the module has small signal gain of 60 dB. The 12 V supply is regulated internally and generates the negative voltage required for the gate bias. Built-in bias sequencing prevents the drain voltages for the amplifier stages from being applied without the negative voltage present, which protects the amplifiers if 28 V is applied without 12 V supply applied.
-
product
Amplifiers
Fully automatic, legal limit plus headroom amplifierAlpha’s low-drive, tube amplifier design delivers the cleanest possible signalOperates on all Amateur Radio Bands 160M thru 10MSingle, easy to find, inexpensive 3CX1500A7 8877 type tubeInternal, automatic 4 port antenna switch capable of combining any 2 antenna portsAlpha’s Legendary service and support4 year limited warranty on hardware, 1 year on tube1500W, 100% duty cycle, no time limitation, key down foreverRugged construction built to last
-
product
8 SE Or 4 Diff. Input Channels, 4 Analog Current Output Channels, PCI Express
APCIE-3121-8-4C
Input range:?± 10 V, 0-10 V software programmable0-5 V, ± 5 V, 0-2 V, ± 2 V, 0-1 V, ± 1 V (gain)0-20 mA (option) ? software-programmable amplifier:PGA x1, x2, x5, x10 ? Conversion triggered through software,scan, timer, external event ? Onboard FIFO buffering for 256 analog values ? Data exchange through 16-bit I/Oor 32-bit memory (PCI DMA) ? Sequence RAM ? Overvoltage protection ? input filter: 160 kHz
-
product
ABex Current Sense Module for Six Channel UUT Supply Monitoring
ABex TM-406 Current Sense
The ABex TM-406 is a six-channel shunt current measurement extension. It’s designed to work in combination with the Konrad ABex TM-501 and PXI-501.Each of the six shunt current measurement units have a passive measurement shunt, an overcurrent protection, a sense bridge relay and the possibility to route the quiescence current to an ABex measurement device TM-501 with PXI-501.In addition, the ABex TM-406 features 8 isolated digital outputs (IDOs), and 12 measurement inputs, which can be routed to the analog bus.
-
product
High-Voltage Amplifiers - to 1000 Volts peak-to-peak
These amplifiers provide high amplitudes and bandwidths, and are well suited for use as booster amplifiers for lower-voltage arbitrary waveform generators.
-
product
Amplifiers, Splitters & Combiners
DEV’s RF Splitters, Distribution Amplifiers, or Dividers are used to distribute and amplify RF signals, to compensate for signal loss, and to provide redundancy paths to ensure maximum uptime.
-
product
Waveform Amplifiers
Most waveform generators are limited to 20V pk-pk EMF output level. The WA301 waveform amplifier can be used to increase that level up to 30V pk-pk.
-
product
DC Bias Current Power Supply
TH1775
Shenzhen Chuangxin Instruments Co., Ltd.
TH1775 is a DC Bias Current Source (or DC Magnetization Current Source) used for inductance measurement of inductors and transformer windings with DC bias current. Except for constant current output, low additional error and wide frequency response range are important for bias current inductance measurement. High frequency LCR meter could be used, when the frequency response range is wide enough. MPU controlled auto current balance technology is adopted to realize AC+DC current overlap and constant current output from 0 to ±20A. Two TH1775 can be paralleled to supply a maximum current up to 40A.TH1775 permits high frequency measurement up to 1 MHz and can be directly controlled by TH2816A, TH2817A, TH2818 and TH2819. TH1773/TH1775 with its low additional error, wide frequency response range and sweep output function is widely used in DC biased inductance measurement. TH1775 also provides a perfect solution for magnetic material analysis.
-
product
Versatile 5-Channel Industrial Amplifier/ Conditioner Instrument
MODEL TIO-3000
The TIO-3000 System was originally designed to perform precision summing on 2, 3 , or 4 load cell signals for weighing applications. Development has progressed into accessory modules with considerable versatility for user defined configurations in a compact economical five (5) slot system with built-in meter and channel selector. Please see below for more information on the four available plug in modules and for available system configurations.
-
product
Integrated Two-Stage Current Sensors
If ultra-low noise performance is required, our integrated two stage devices are the number one choice. With input inductances from 24 nH to 1.8 µH and a flux-noise level as low as 0.8 µPhi0/sqrt(Hz) an energy resolution of about 45 h is attained. The devices consist of a 16 SQUID series array as amplifier stage and a single front-end SQUID.
-
product
Through Hole type DC Current Sensor/for DC Leakage Current Measurements
DCZCT-45NK
MULTI MEASURING INSTRUMENTS Co., Ltd.
*DC earth fault measurement*DC leakage current measurement*Least affection from the magnetization of core and temperature fluctuation*Convenient +24V single polarity power supply
-
product
High-Voltage, High Current I/O Module
Model JI-4516
The JI-4516 module is a versatile, easy-to-use device for adding high-voltage, high-current digital I/O capability to a computer system via a USB connection. The module is comprised of 8, low-side power MOSFET switches, and 8 high-voltage inputs. I/O ground isolation eliminates ground-loops and provides protection from noise and switching transients during high-current load switching. The JI-4516 is available as either a desktop unit or low-cost OEM board.
-
product
Current Probe Calibrator
KSZ
PMK Mess- und Kommunikationstechnik GmbH
Since Current Probes are often exposed to hard working conditions, a performance check is recommendedbefore every use. These Current Probe Calibrators generate square wave pulses from 0.05 A to 1000 A with an accuracy better 1%. They qualify for calibration and adjustment of Current Probes.
-
product
23 GHz Low Noise Amplifier
HMMC-5023
The HMMC-5023 is a GaAs MMIC low noise amplifier designed for moderate gain and low noise from 21 GHz to over 30 GHz. Typical applications of the HMMC-5023 include digital radio communications systems that operate within the 21.2 GHz to 23.6 GHz and 24.5 GHz to 26.5 GHz frequency bands. Moderate gain and low noise temperature make it ideally suited as a front-end gain stage.
-
product
Digital Clamp Current Tester For High Voltage
HCL-36UX
MULTI MEASURING INSTRUMENTS Co., Ltd.
・Display measurement value on your smartphone through blue-tooth connecting.・Measurement value can be kept in the our cloud server.・In addition to measured values, location registration by GPS, temperature, date and time can also be saved.
-
product
RF Amplifier
SA812
Hangzhou Softel Optic Co., Ltd.
SA812 860mhz CATV outdoor trunk amplifier are mainly used for Bidirectional trunk transmission for CATV television image signal, digital TV signal, telephone voice signals and data (or compressed data) signal.
-
product
PXI/PXIe Battery Simulator Module, 2-Channel, Simplified Current Sink, 750 V Isolation
41-752A-903
Targeting EV, automotive, aerospace, energy storage and electric aircraft applications, the new battery simulator modules occupy a single PXI slot. These 2-channel battery simulators are capable of supplying up to 7 V and 300 mA per channel. The channels are fully isolated from ground and from each other, allowing series connection to simulate batteries in a stacked architecture.