Showing results: 76 - 90 of 1830 items found.
-
W-TW-24 -
Physitemp Instruments
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
W-TW-40 -
Physitemp Instruments
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
W-TW-36 -
Physitemp Instruments
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
W-TW-44TEF -
Physitemp Instruments
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
W-TW-40P2 -
Physitemp Instruments
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
W-TW-36P2 -
Physitemp Instruments
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
W-TW-30 -
Physitemp Instruments
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
W-TW-40P -
Physitemp Instruments
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
W-TW-26 -
Physitemp Instruments
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
IEC60695-2-10 -
Shenzhen Chuangxin Instruments Co., Ltd.
Thermo resistance, spare part set of Glow Wire Apparatus Acc IEC60695-2-10. Thermo resistance loop is a wire loop that is defined at a temperature and is pressed against a standardized test platelet made of plastic (or other materials) for a prescribed period of time under precise test conditions.
-
PT-1500 -
Molex, Inc.
PT-1500 Bench-Top Wire Crimp Pull-Force Tester, Manual Lever-operated for 5.84mm 8-30 AWG
-
1301270009 -
Molex, Inc.
Super-Safeway Three Wire Circuit Tester, 3 Indicating Lights & Receptacle Tension Tester in Carrying Case
-
Labfacility Ltd.
The Thermocouple Welder, manufactured by Labfacility, is a compact, simple-to-use instrument designed for thermocouple and fine wire welding.
-
A909 -
AGM Elettronica
The A909 is a wireless system that allows to detect wire breaks for cabling machines having no sliding contacts brushes.
-
CX-Z17 -
Shenzhen Chuangxin Instruments Co., Ltd.
IEC60695-2-1 CX-Z17 High Precision Glow Wire Tester is desinged according to IEC60695-2-1, IEC60695-2-13, UL746A, IEC829, DIN695 and VDE0471 etc. standards.The IEC60695-2-1 CX-Z17 High Precision Glow Wire Tester is suitable for resistance to abnormal heat and fire test on lighting lamps, electronic products and household appliances.