Showing results: 1546 - 1560 of 1821 items found.
-
PeakTech Prüf- und Messtechnik GmbH
User-friendly tester for non-contact voltage testing from 50 V to 1000 V AC. Suitable for outlets, lamp sockets or against wire insulation testing. If AC voltage is present at the relevant measuring point, this is indicated visually by a flashing red LED and the integrated buzzer sounds. If the measuring point is voltage-free, the test probe lights up permanently green.
-
Jackmark Engineering Ltd.
With automotive interior designs becoming more luxurious, cabin space features such as ambient lighting and seat / steering wheel controls have increased the demand for interior wiring testing. Jackmark Engineering has years of experience supplying test equipment for instrument panel manufacturers and have increased their portfolio to include all aspects of interior wire harness testing.
-
CA-60 -
Tecpel Co., Ltd.
This miniature clamp meter features two Hall effect sensors. For use with any multimeter with 200mV or/and 2V ranges for direct readout input impedance of least 1M ohm. High conversion factor for low DC and AC mA measurement. With the small jaw size it can fit into tight space in circuit panel or wire bundle to take the reading.
-
RK7112 -
Shenzhen Chuangxin Instruments Co., Ltd.
The tester is applied to the home appliances, computer peripheral equipment, electric products, communication products, lighting products, small home appliance products, lighting equipment, electronic components, transformers, motors, compressors, electric heat pipe, wire, cable and high voltage safety system’s withstand voltage and leakage current test, as well as it’s an indispensable dielectric
-
LX-680 -
Shenzhen Lian Xin Technology Co., Ltd.
The system provides Chinese/English free switch operation interface·Starting up conducts self-diagnosis and self-correction·The system can scan and direct automatically.·The system provides advanced instant open-circuit, short-circuit, continuity test, can test the wire break·It can function as unilateral, standard, multi-segment and spot test of wire·The maximum test voltage is AC1000V / DC1500V·The maximum test spot is 256.
-
all-sun
Non-Contact Voltage Tester uses non-contact voltage detection technology for the detection of voltage in cables, cords, circuit breakers, lighting fixtures, switches, outlets and wires. The tester provides accurate test readings for use at the job site, in the shop and at home. This tester features high-quality electronics and heavy-duty polycarbonate plastic resins for a state-of-the-art construction that is comprehensive, reliable and durable.
-
Extech MN36 -
Extech Instruments Corporation
The Extech MN36 digital multimeter is compact but still packed with features. Capable of measuring AC and DC voltage up to 600 volts, the MN36 is autoranging, which means it automatically displays readings with the proper decimal place location and maximum resolution. Comes with protective rubber holster, 2xAAA batteries, bead wire Type K temp. probe and test leads.
-
PC2M -
Vetek Weighing AB
PC2M signal calibrator has been realised to perform periodicalchecks and calibrations on indicators with a 2mV/V input anda 4 or 6 wires systems. Provided with a main switch with 6 selectable steps, it allows to control the linearity on both positive and negative field. Internally, the 350W full bridge unbalancing, is generated by high stability passive resistances (1 ppm/C).
-
FF310 -
General Technologies Corp.
42 V Ready: for use in the new generation of vehicles with mixed or single 42 Volt systems. Operates on DC voltages from 6 to 42 volts. Internally protected against power surges and overloads. 8" flexible probe allows reaching wires in congested places. Transmitter and Receiver LEDs show open or short circuit conditions.
-
CR -
Cirris Systems Corporation
As a wire harness tester, a cable tester, a continuity tester, a component tester, and a guided harness-assembly aid, the Easy-wire CR tester is versatile. The easy-wire CR features Windows based software that allows you to create custom graphics of your connectors and light LEDs to guide the harness assembly process. Test Points: 256-32,000, Test Current: 6.5 mA max
-
Fluke T6-1000 -
Iconic Engineering Limited
We know operating in electrical boxes packed with wires may be difficult once you’re attempting to seek out a secure gold contact purpose. Now, with Fluke’s T6-600 or T6-1000 with integrated FieldSense technology, you'll be able to quickly and simply take measurements by slippery the open deliver a conductor to visualize the voltage level without the need for test leads.
-
781473-02 -
NI
The PXIe‑8431/16 is a high-performance interface for high-speed communication with RS485 and RS422 devices. It features high-performance DMA transfers, multithreading, and multiprocessor support. You can also select between 4‑ and 2‑wire transceiver modes for full‑ and half‑duplex communication. NI serial interfaces also appear as standard COM ports for compatibility with programs that use serial communications.
-
SCOUT -
MAC Panel
SCOUT is an innovative pull-through Mass Interconnect solution specifically designed to deliver the full performance potential of the PXI platform at the ATE interface. SCOUT, featuring DAK (Direct Access Kit) connectivity, enables system designers to limit or eliminate traditional instrument cables by replacing them with DAK connection modules that utilise PCB, flex-circuit or short wire connections.
-
780592-02 -
NI
The PCIe‑8431/16 is a high-performance interface for high-speed communication with RS485 and RS422 devices. It features high-performance DMA transfers, multithreading, and multiprocessor support. You can also select between 4‑ and 2‑wire transceiver modes for full‑ and half‑duplex communication. NI serial interfaces also appear as standard COM ports for compatibility with programs that use serial communications.
-
782124-01 -
NI
The PCIe‑8431/2 is a high-performance interface for high-speed communication with RS485 and RS422 devices. It features high-performance DMA transfers, multithreading, and multiprocessor support. You can also select between … 4‑ and 2‑wire transceiver modes for full‑ and half‑duplex communication. NI serial interfaces also appear as standard COM ports for compatibility with programs that use serial communications.