Product
Standard 0.30 (8.50) - 1.06 (30.00) Battery Probe
BIP-3
Battery Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 60Recommended Travel (mm): 1.52Mechanical Life (no of cyles): 250,000Overall Length (mil): 511Overall Length (mm): 12.98
-
Product
IEC-IEEE-CSA-IS Standards
-
MOTOMEA RDS Automatic IEC-60034-2-1 Test Bench solutions are complete turnkey systems and provide a full implementation of the IEC 60034-2-1, IEEE 112-2004, CSA C390-10 standards
-
Product
Standard 1.08 (31.00) - 4.00 (114.00) Long Travel Bead Probe
BPLT-25HL-4
Bead Target Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,460Overall Length (mm): 37.08Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, Alternate Spring 400 mil / 10,16 mm, High Spring: 400 mil / 10,16 mm, Ultra High Spring: 350 mil / 8,89 mm
-
Product
Standard 2.00 (57.00) - 3.60 (102.00) General Purpose Probe
P2664G-1C1S
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 10Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 114Full Travel (mm): 2.90Recommended Travel (mil): 84Recommended Travel (mm): 2.13Overall Length (mil): 895Overall Length (mm): 22.73Overall Length Remark: Tip 1C: 845 mil (21.46 mm) Tip 2R: 935 mil (23.75 mm)
-
Product
Safety Network (AS-i Safety at Work)
-
*Monitoring of up to 31 safe AS-i slaves*Applications: door monitoring, light curtains, e-stop, two-hand control*Safe AS-i modules for field applications and control cabinets*Safe AS-i door switches with guard locking and guard lock monitoring
-
Product
Automatic Battery with Filters with Standard Contactors
BATLVF600
-
Lifasa - International Capacitors, SA
LIFASA automatic capacitor banks are used for centralized compensationof power factor in low voltage instalations.
-
Product
Standard 1.02 (29.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-62J-4
ICT/FCT Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2B40
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
Standard 1.08 (31.00) - 4.00 (114.00) Long Travel Bead Probe
BPLT-25HF-4
Bead Target Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,460Overall Length (mm): 37.08Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, Alternate Spring 400 mil / 10,16 mm, High Spring: 400 mil / 10,16 mm, Ultra High Spring: 350 mil / 8,89 mm
-
Product
Standard 1.00 (28.00) - 1.80 (51.00) General Purpose Probe
P2662BG-2V1S
General Purpose Probe
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 68Full Travel (mm): 1.73Recommended Travel (mil): 50Recommended Travel (mm): 1.27Overall Length (mil): 575Overall Length (mm): 14.60
-
Product
Capacitance Standard Frame
AH 1100
-
The AH 1100 capacitance standard frame containing from one to four AH 11A fused-silica capacitance standards provides reference capacitors of unexcelled stability. The inherent stability of this system when subjected to mechanical or thermal shock makes it the ideal transfer standard for capacitance. The built-in precision temperature controllers make it a simple, reliable system to use.
-
Product
Standard VXI Module Shield Kits With Address Switch Opening
-
* Single-slot kit fits all VXI-1 Revision 1.0 to Revision 3.0 chassis.* Clamshell design fits C-size modules with 96-pin connectors.* Side shields include connector shrouds for maximum shielding.* RFI limiting, air vent slots along top and bottom edges for good air circulation thru the module.* Extruded front panel is bend resistant.* Address switch opening on component side shield.* Complimentary layout support includes PCB design template and CAD layout files.
-
Product
Standard 0.70 (2.00) - 1.70 (4.80) General Purpose Probe
P2662AG-1R1S
General Purpose Probe
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 710Overall Length (mm): 18.03
-
Product
Dytronic Primary Transfer Ultra Stable Standard
RD-22 Ultra
-
The RD-22 Dytronic Primary Transfer Ultra Stable Standard represents the state-of-the-art technology in a commercially available AC transfer reference. The Ultra Stable RD-22 is a variant of the RD-22 Primary Transfer Standard that has been optimized for 120/240 V @ 5A operation to provide optimum stability. In a stable test environment, repeatability for a 10-second test of ±0.6 µWh/VAh is attained at 120 V and 240 V at 5A inputs with a 95% confidence interval. A typical experimental 2 repeatability of less than ±0.25 µWh/VAh is achieved. In a stable test environment, a reproducibility of ±2 µWh/VAh over a five-day interval is attained at 120 V and 240 V at 5A inputs with 95% confidence interval.
-
Product
Standard Series
-
TPC-100W Series offers versatile web terminals in 7", 10", 15.6" and 21" displays, designed for factory control systems
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25I15-4
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
NTSC Standard Pattern Generator
PG315N
-
The MicroImage PG315 pattern generator is designed for simple size and geometry reference applications. The PG315 will overlay one of five standard patterns including a centered cross line, a centered cross hair, a centered target style symbol, a dot grid (cross dot) array, a hatch grid (crosshatch) array.
-
Product
Standard 3.06 (86.70) - 4.00 (113.40) RF Probe For SMA Connectors
CSP-30ES-013
High Frequency Probe
Nominal Impedance (Ohms): 50Current Capacity (Amps) @ 20° C: 1.00Bandwidth @ -1dB (GHz): 35.00Return Loss @ -20dB (GHz): 22.00Test Center (mil): 328Test Center (mm): 8.33Recommended Travel (mil): 100Recommended Travel (mm): 2.54Full Travel (mil): 200Full Travel (mm): 5.08Overall Length (mil): 1,033Overall Length (mm): 26.24Rec. Mounting Hole Size (mil): 297Rec. Mounting Hole Size (mm): 7.54
-
Product
Standard - 1.44 (41.00) - 4.50 (128.00) High Current Probe
HCP-13P
High Current Probe
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1P-4-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard Clamp Meters
-
For extreme temperatures, choose an analog clamp meter that can measure amps and volts without needing batteries.
-
Product
DC High Current And Power Resistance Standards
-
Specialized high-accuracy electrical metrology equipment designed to measure, source, and calibrate high direct current (DC) and power levels with extreme precision and low uncertainty.
-
Product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3F
General Purpose Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Uniformity Calibration Standards
-
Integrating sphere light sources with halogen lamps or LEDs for generating luminous fields with uniform luminance distribution. Traceable calibrations of luminance or spectral radiance in the wavelength range from 250 nm to 2500 nm.
-
Product
Standard 0.79 (23.40) - 1.75 (49.60) General Purpose Probe
HPA-40G
General Purpose Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 35Test Center (mil): 39Test Center (mm): 1.00Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 660Overall Length (mm): 16.76
-
Product
Vector Network Analyzer (VNA) Simulator – Standard
S94050B
Vector Network Analyzer
S94050B puts flexible S-parameter analysis into your own computer. Dive deeper into measurements captured on a network analyzer or develop and optimize test programs before deploying them onto an instrument.
-
Product
Standard 1.02 (29.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-62T1-4
ICT/FCT Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 0.83 (23.50) - 2.85 (80.80) Battery Probe
CCA-004
Battery Probe
Current Rating (Amps): 10Average Probe Resistance (mOhm): 50Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 57Full Travel (mm): 1.45Recommended Travel (mil): 40Recommended Travel (mm): 1.02Overall Length (mil): 470Overall Length (mm): 11.94