Product
Automatic Current Transformer Comparator
KATC-C2
-
Got older, slower equipment? Knopp’s Automatic Current Transformer Comparator (KATC-C2) is faster, more robust and more accurate! Knopp’s KATC-C2 is a high accuracy current comparator that is compatible with all older generation Knopp comparators, and is designed to be a direct, plug-in replacement requiring no modification of the existing Knopp Current Transformer Test Systems. Save time and money on service by upgrading your comparator to our new next generation model!
-
Product
Equipment Condition Indication
MetalSCAN
-
Condition indication in real-time, so you can schedule maintenance at the right time.MetalSCAN is the leading real-time, on-line condition indication technology designed to alert equipment operators to bearing and gear damage, long before equipment failure. Nothing else comes close. Its advanced capabilities deliver knowledge that transforms equipment failure to predictable and avoidable high cost events. Use MetalSCAN to optimize maintenance schedules, reduce repair costs, increase reliability and improve safety.
-
Product
Digital Tap Position Indicator With Voltage Display
-
NMC's Digital Tap Position indicator with Voltage Display, type: TX-202, is used to indicate the Tap Position of the Power Transformer with On Load Tap Changer as well as also indicates the voltage.
-
Product
Transformer Analyzer
505
-
The UTEC 505 Transformer Analyzer is designed for testing current transformers (CT) and potential transformers (PT) without interruption of the customer’s service. This instrument measures CT admittance, CT ratio, CT primary-to-secondary phase angle and the voltage, current and phase angle of the service. With the ‘Burden CT/PT Option’, it determines the CT secondary burden capability, the regulation of the PT and its secondary burden capability and provides for CT core demagnetization.
-
Product
Reactive Energy Regulator
MASTER
-
Lifasa - International Capacitors, SA
It measures the reactive power needs of an installation and gives the corresponding capacitor connection and disconnection orders to keep the cos φ preset. At the same time it allows to measure the main parameters of an installation (voltage, current, harmonics, active power, reactive power, etc.), by using 1 or 3 current measurement transformers.
-
Product
EDM Post Analyzer Software
-
The Post Analyzer application is used for the post processing of previously recorded time stream data. Post processing includes data conditioning, Fourier transform operations, and specialized analyses such as order tracking and octave analysis.
-
Product
PCI Bus Synchro - Resolver - LVDT I/O Cards
PCI Synchro
-
Computer Conversions Corporation
Proven "Whole" Std. ConvertersOptimized Thermal ManagementExternal Synchro AMP I/O100% Transformer Isolated I/OPermits 2 wire X/Y Stators(Air)No External Parts or Power RequiredReference Powered(NAVAL) Options10-16 BIT Resolution ProgrammableVirtually Indestructible Outputs1.2 to 4.5VA High Power ModelsMix/Match Input & Output TypesSimultaneous Fine/Coarse Transmit For Multispeed Outputs
-
Product
Surge Tester
-
Educated Design & Development, Inc.
An electronic testing device used to evaluate the condition of electrical insulation in coils, transformers, and electric motors.
-
Product
GDGS Transformer Power Factor And Tan Delta Tester
-
Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd
GDGS Transformer Power Factor and Tan Delta Tester
-
Product
High Voltage System
HV-2
-
International Electro-Magnetics, Inc.
*Tests Power Transformers for Continuity, Ratio and Phase. Applied and Induced Potential and No-load Losses.*14 Conductor Switching Matrix will test 7 individual windings, 13 taps of one common winding or some combination thereof. (10 Amp current limit)*The System Control is Windows/Visual Basic based. Menu screens allow full selection of test parameters and sequence. Low voltage tests can be performed first, allowing defective parts to be rejected without proceeding to time consuming induced Potential dwell routines. Test data labeling and data acquisition software can be easily added to the system.
-
Product
Fourier Transform Infrared Spectrophotometer
IRTracer-100
-
This system achieves excellent sensitivity with an SN ratio of 60,000:1, high resolution at 0.25 cm-1, and high-speed scanning capable of 20 spectra/second. The performance of medium and higher end models is supported by high reliability including advanced dynamic alignment and an interferometer with a dehumidifier. This is compatible with applications active in a variety of circumstances, with a library of approximately 12,000 spectra and data analysis programs for contaminant analysis, and time course and rapid scan programs for reaction tracking.
-
Product
Dissolved Gas Analyzers
-
Identify and monitor critical transformer fault types with dissolved gas analyzers that easily retrofit existing transformers or can be made specifically for new builds
-
Product
PXI/PXIe LVDT, RVDT, Resolver Simulator Modules
-
Linear variable differential transformers (LVDT) are electrical transformer sensors to measure linear displacement. Driven by an AC excitation source, the LVDT generates a pair of AC output signals modulated according to the core's mechanical position (displacement). LVDTs have been widely used in applications such as power turbines, hydraulics, automation, aircraft, satellites, nuclear reactors, and many others. These transducers have low hysteresis and excellent repeatability.
-
Product
Total Substation Maintenance Program
-
S. D. Myers' Solutions offers Substation Maintenance Services which provide the means to solve your substation and transformer needs. One phone call gives you access to the S. D. Myers' team, our expertise and experience, as well as our network of partnerships, all working toward the goal of extending the relaible and cost-effective life of your substation equipment.
-
Product
Transformer Testers
-
*Quickly tests deenergized power distribution transformers*Briefly energizes the transformer and takes a snapshot of the condition by measuring the voltage, current and power factor of the test signal*Tests overhead, pad-mount and distribution transformers*Audible alarm confirms successful test*Improve SAIDI statistics by quickly testing and getting the transformer back in service*Auto self-test performed with every test*Compact, lightweight and easy-to-use
-
Product
Gas-insulated AC Test System
-
Yangzhou Power Electric Co., Ltd
The test system is used to do AC voltage withstand test and PD measurement for high voltage insulation products, combined electrical equipment, instrument transformers, etc.
-
Product
Chroma Milliohm Meters
-
Chroma Systems Solutions, Inc.
The Chroma 16502 Milliohm Meter is Chroma’s newest digital Milliohm Meter. 0.001mΩ~1.9999MΩ wide measurement range. DC, Pulsed, and Dry-circuit test current driving modes, enable the Chroma 16502 can be properly used in DC resistance measurement for various inductive components (coil, choke, and transformer winding etc.), cable, metallic contact (connector, relay switch etc.) and conduction materials.
-
Product
HIGH VOLTAGE SCR CONTROLLED POWER SUPPLY
xPS Series
-
High Voltage SCR Controlled Power Supply, P/N 18278PSPower Rating: 350 KW.Input: 480 VAC, 3 PH, 60 HzOutput: 0 to 5000 VDC, 70 Amps maxRipple: 2 % approximately at maximum rated voltageConfiguration: 12 pulse externally SCR controlled rectifier systemProtection Devices:Input contactorsOverload relay shutoffInput surge suppressorThermal switchesOutput current limiting resistor (made with 5 Ohm Kanthal heating element)Emergency power shutoffCooling: Each 6 pulse rectifier assembly is cooled by three 10” fansInterface: 4/20 ma converter interface for output voltage and output current to SCR controller.Enclosure: The overall dimension of the unit is (78”H x 38”W x 53”D). It is comprised of two separate enclosures each with dimensions of (78” H x 38” W x 26” D) which are integrated together to form a single enclosure. Each half enclosure has one 6 pulse transformer and one 6 pulse high voltage rectifier.Weight: Approx. 5000 lbs.SCR Controller: The 12 pulse SCR controller is supplied by the customer. We were responsible for the 12 pulses Transformer and 12 pulses Rectifier section. Portability: Unit can be lifted up with a fork lift. It can also be moved around with a 5000 lb pallet jack.Transformer: Two 200 KVA transformers are used to step 480 VAC to 3750 VAC each in a 12 pulse configurationRectifiers: Two 6 pulse rectifier assemblies capable for 5000 VDC and 60 Amps output were used. The high voltage rectifier assemblies are isolated and protected in a fiberglass plenum within the enclosure.Blocking Diode: Each diode of the 6 pulse rectifier consists of 10 diodes in series to offer a blocking voltage of 12000 V (PIV)
-
Product
Linear Variable Differential Transformers (LVDTs)
-
Whilst there are several ways to measure displacement, the Linear Variable Differential Transformer (LVDT) remains a popular transducer in most industrial applications. LVDTs initially were used as a means of taking dimensional readings in laboratories. They gained popularity in a wide variety of industrial monitoring and control applications, and whilst an LVDT is used to measure displacement the technology can be employed within other transducer types.
-
Product
DC Power Supply
◎PW-4063R
-
*Use Toroidal Transformer. Low EMI & High EMS.*Triple output, 0-32V/0-6A X2 and 5V/3A .Max. 400Watts*Tracking operation. Max. output 64V/6A on tracking series or 32V/12A on tracking parallel.*4 display, Green LED shows Voltage and Red LRD shows Current. Easy to read.*Compact design. G.W. 9Kgs only. Easy to handle.*The resolution of PW-4063R as high as 0.01v and 0.001A.*Provide 4Pcs 10turns micro adjust VR for Voltage and Current adjustment. Easy to operate.*Very low Ripple & Noise, less than 0.4mVrms. Very suit for precise measurement.
-
Product
DC Resistance Tester
DCSS502BC
-
Resistance meter is designed to measure copper resistance of transformers, wires, cables, other conductors and other coil products etc. It is widely used of low resistance measurement of switches, heater wires, transformers, relays, motors, electric films and PC circuit boards, wires, cables, etc. With reliable Good/ NG judgement, it is a premier resistance meter for the use in production line or QC department.
-
Product
Power Factor Correction
HV/MV
-
Power Capacitors for medium voltage network:Ducati Energia proposal includes range of single and three-phase capacitors up to 800 kVAr with max HSV of 36kV.Upon request,we provide them with internal fuses stainless steel cases,inrush reactors,expulsion fuses as well.System is designed according to the specific application and it is composed by current transformers (CT),voltage transformers (VT) and relais.
-
Product
4 Way Fiber Optic Return Path Receiver (low Optical Input)
MX4RR-LI
-
The MX4RR-LI transforms return optical signals to RF signal output. The standard 1U chassis integrates 4 independent receiver modules, it can receive up to 128 return optical signals from burst mode mini-nodes or services for 128 RFoG optical network units (ONU)-Mini-Nodes.
-
Product
GPIB-RS232, Serial, RS232 GPIB Instrument Control Device - Universal Euro 240VAC
779732-04
-
The GPIB‑RS232 is an IEEE 488 controller device for computers with an RS232 port. You can use this device to integrate an instrument into your system using GPIB. This device transforms a computer with an RS232 serial port into a talker, listener, or controller on the GPIB bus. It can also interface RS232 instruments and peripherals to the GPIB bus. It can implement the physical and electrical specifications of the IEEE 488 and RS232 standards, as well as interpret and execute high-level commands from the serial port, including RS232‑to‑GPIB and GPIB‑to‑RS232 protocol conversions. This device is IEEE 488.2 compatible. The device includes a license for the NI‑488.2 driver software, providing maximum reliability for connecting to third-party instruments with GPIB.
-
Product
GPIB-RS485, GPIB Instrument Control Device
779733-04
-
Serial, RS485/RS422 GPIB Instrument Control Device - The GPIB‑RS485 is an IEEE 488 controller device for PCs with RS485 or RS422 ports. You can use this device to integrate an instrument into your system using GPIB. This device transforms a computer with an RS485 or RS422 … serial port into a talker, listener, or controller on the GPIB bus. It can also interface RS485 and RS422 instruments and peripherals to the GPIB bus. It can implement the physical and electrical specifications of the IEEE 488, RS485, and RS422 standards, as well as interpret and execute high-level commands from the serial port, including serial‑to‑GPIB, and GPIB‑to‑serial protocol conversions. This device is IEEE 488.2 compatible. The device includes a license for the NI‑488.2 driver software, providing maximum reliability for connecting to third-party instruments with GPIB.
-
Product
Three-phase Electricity Meters
-
Three-phase static electricity meters AMT B1x-S(D)xxTE are determined for single-rate or double-rate active energy measurement in direct and indirect connection, displaying results on mechanical register with stepping motor. In the case of CT (current transformer) operated meters (x/5A) it is necessary value of register to multiply by the current transformer ratio.
-
Product
Instrument Transformer Calibrators
CTPT 81
-
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Tests: Ratio error. Excitation current and curve. Polarity CT / PT TESTER
-
Product
Incremental Transformer Solutions
TRANSPORT X
-
The Kelman TRANSPORT X is a compact portable Dissolved Gas Analysis (DGA) system which can be used to analyze oil samples for all dissolved fault gases and moisture. If abnormal levels are detected, it further provides a diagnostic using various IEEE/IEC approved interpretation rules.
-
Product
AC Current Transducer
iDVM 333
-
The iDVM 333 AC Current Transducer plugs into the iDVM 510 multimeter and measures current (as AC millivolts) with no need to break the circuit. Special Introductory Price: $52.50FeaturesTransformer jaws that detect AC current flowing through a conductorSelectable sensitivity between 1mV/A and 10mV/AHand Guard to protect your hand for safetyLarge, easy-to-operate trigger opens the transformer jaws
-
Product
TCoE Setup
-
Alignment of the QA strategy to your business goals is critical to ensure that the QA enterprise is able to deliver on the dynamic expectations of the business. While the quality of your applications is an essential metric for the QA enterprise, it also needs to focus on continuous improvement and to be ready for future technologies. At TestingXperts, we help you transform your QA to a next-gen organization by setting up a Testing Center of Excellence (TCoE).