-
product
Flow Cytometer
Nowadays, quality control is a key part of any industrial process, in line with dynamically changing standards, and creation of new standards and protocols in accordance to each industry. Flow cytometry is a widely used bioanalysis technique in a larger number of applications. Extensively used in fields like microbiology, the technology has also proven benefits in the food and agrifood industry. A potential application is the absolute somatic cells count in the milk. Flow cytometry can also be applied for environmental and sanitary microbiology for applications such as detection of bacterial cells in milk or water for quality control and assurance testing.
-
product
Stopped-flow/quench Flow
The SFM-4000 stopped-flow series is available for single, double or triple mixing applications (two reaction steps or one reaction step and one concentration change step before the final observed reaction). The SFM-4000 stopped-flow family has been designed to ensure the shortest possible dead time the highest precision and to minimize sample consumption as much as possible.
-
product
Mass Flow Controller for Medium Flow
HFM-201 / HFC-203
The HFM-201/HFC-203, Teledyne Hastings' flexible, general purpose series of mass flow meters and controllers accurately measure and control mass flow in a variety of applications. Featuring reliability and stability, the 200 Series is chosen for its very stable performance with varying ambient conditions. A wide choice of elastomer seals make this flow controller compatible with most gases.The HFM-201 / HFC-203 meters and controllers have flow ranges from 0-25 slm to flows of 0-1000 slm; provide analog outputs, are constructed of stainless steel and can be configured with normally open or normally closed valves. The full scale range is specified by the end user. A NIST traceable calibration certificate is standard. Many corrosive gases and pressures up to 1000 psig are easily measured. Cleaning for oxygen service is available.
-
product
Digital "A" Flow Controller for Low Flow
HFM-D-300A / HFC-D-302A
All Metal, Fast Response, Tight Accuracy!Mass flow techniques provide RELIABLE, REPEATABLE AND ACCURATE gas flow rate measurements.HFM-D-300A / HFC-D-302A mass flow instruments have flow ranges from 0-5 sccm to 0-25 slm; use all metal seals, provide analog and digital outputs, and are constructed of stainless steel. Easy, user friendly digital communications with windows based software interface available.Self diagnostics of the sensor, valve and overflow are included in the digital features. Also of interest is the auto zero feature which detects when the valve is closed and automatically resets the zero. These mass flow meters and controllers can store up to 10 calibrations of different ranges and gases. Another feature is the built in totalizer for monitoring gas usage under user set conditions.
-
product
Mass Flow Controller for Low Flow
HFM-200 / HFC-202
The HFM-200/HFC-202 is Teledyne Hastings' flexible, general purpose series of mass flow meters and controllers. Featuring reliability and stability, the 200 Series is chosen by OEM's for its very stable performance with varying ambient conditions. A wide choice of elastomer seals make this flow controller compatible with most gases.
-
product
Flow Meter
Model 001
It provides a cost-effective and reliable method of monitoring flow in a variety of environments, including salt, fresh and effluent water, from shallow streams to tidal waterways. The meter benefits from the design of the impeller bearings, which give low threshold velocity and consistent performance. Available as either wading or a suspension set, all systems are supplied with the Model 0012B real-time control display unit.
-
product
Micro Flow Sensor
2000
The Signet 2000 Micro Flow Sensor is constructed from Polyphenylene Sulfide (PPS), which provides high material strength. The 2000 MicroFlow Sensor offers two flow ranges starting at 0.11 or 1.13 lpm (0.03 or 0.3 gpm), for clean process liquids, regardless of fluid color or opacity.
-
product
Flow Meter / Monitor
NivuFlow Mobile 600
The NivuFlow Mobile 600 was developed particularly for long-term measurements in field operation without external power supply. Measurements for checking and verifying can be carried out with the self-sufficient and portable system without any problems even in harsh environments. Battery lifetimes of several weeks or even months reduce personnel costs for maintenance and data readout significantly.
-
product
Digital "A" Flow Controller for Medium Flow
HFM-D-301A / HFC-D-303A
Mass flow techniques provide reliable, repeatable and accurate gas flow rate measurements.HFM-D-301A/HFC-D-303A mass flow instruments have flow ranges from 0-25 slm to 0-1000 slm; provide analog and digital outputs, and are constructed of stainless steel. Easy, user friendly digital communications with windows based software interface available. Available with a variety of elastomer seals for maximum flexibility.Self diagnostics of the sensor, valve and overflow are included in the digital features. Also of interest is the auto zero feature which detects when the valve is closed and automatically resets the zero. These mass flow meters and controllers can store up to 10 calibrations of different ranges and gases. Another feature is the built in totalizer for monitoring gas usage under user set conditions.
-
product
Ultrasonic Flow Meters
Dalian Taijia Technology Co.,Ltd
RS485 .4-20mA and OCT output● 4-20mA and PT100 platinum resistance input● 2×20 English letters LCD display● 4 key tactile-feedback membrane keypad● IP57● Operate with clamp on, insertion and flow-cell transducer● Pipe diameters from 15mm to 6000mm
-
product
Spectroelectrochemical Flow Cell
SEC-2F
Using the spectroelectrochemical flow cell, it is possible to have a different optical path length changing the gasket. We offer, as an optional item, a silicon and Teflon gasket with a 100, 250 and 500 m of the thickness. SEC-2F Spectroelectrochemical flow cell was designed to fit perfectly in the SEC2000 Spectrometer, and it eliminated the use of the optical fiber to connect the Spectrometer to the SEC-2F. Even for another brand of the spectrometer, you can connect the SEC-2F using the collimating lens and optical fiber.
-
product
Flow Cytometry
The iQue® Advanced Flow Cytometer allows researchers to acquire and analyze high content, multiplexed assays needed to assess immune cell function by combining cell immuno-phenotyping, cell health, and secreted protein (cytokine) analysis in every well of a microtiter plate. Accelerate your research by resolving complex cellular research questions via multiplexed analysis in a single well.
-
product
Thermal Flow Splitter
FS-3000
FS-3000 combines HORIBA STEC’s mass flow controller (MFC) and MuCube (Master controller). By controlling MFC from MuCube equipped with the HORIBA STEC’s proprietary control algorithm, FS-3000 achieves stable splitting control.
-
product
Melt Flow Indexers
Tinius Olsen is proud to introduce our latest evolution of melt indexer to meet almost every need. This new model, the MP1200, meets, and surpasses, all the requirements of Procedure A and Procedures B, C and D of ASTM D1238.
-
product
Cross Flow Cell
Working electrodes for flow cell are mounted on blocks of PEEK. This resin protects the electrodes from external noise and allows researchers to utilize them regardless the content of mobile phase of HPLC because of their hard, organic solvent-resistance. Glassy carbon is usually chosen for the redox reaction study on liquid chromatography. Platinum, Gold, Carbon paste and Nickel electrodes are utilized for special purposes. Thin Layer Cell has been used as a electrode for research such as flow injection analysis (FIA) and the HPLC.
-
product
Mass Flow Controller for Low Flow
HFM-200 / HFC-202
The HFM-200/HFC-202 is Teledyne Hastings' flexible, general purpose series of mass flow meters and controllers. Featuring reliability and stability, the 200 Series is chosen by OEM's for its very stable performance with varying ambient conditions. A wide choice of elastomer seals make this flow controller compatible with most gases.The HFM-200 / HFC-202 meters and controllers have flow ranges from 0-10 sccm to flows of 0-25 slm; provide analog outputs, are constructed of stainless steel and have normally closed valves. The full scale range is specified by the end user. A NIST traceable calibration certificate is standard. Many corrosive gases and pressures up to 1000 psig are easily measured. Cleaning for oxygen service is available.
-
product
Pitot Tube Flow Meter
PTFM-1000V2
The Pitot Tube Flow Meter, PTFM-1000V2 is a standalone interface for measuring exhaust gas flow rate of combustion engines. The system uses the tried-and-tested pitot tube principle with high-frequency transducers to accurately measure highly pulsating exhaust flows with a sampling rate of 1kHz. This rapid capture rate ensures that any pulsations or exotic behaviour in an engine is measured, and the unique design of the PTFM pitot tube means reverse flows can be measured with the same guarantee of sensitivity. The interface can be run standalone with a laptop, or seamlessly integrated to run alongside an analyser system without adding any more steps to the test cycle process.
-
product
Flow Measurement for Liquids
We provide reliable flow measurement devices for clean, slight and heavily polluted media as well as a very wide variety of sensors. Our hydraulic flow measurement systems as well as our radar and ultrasound-based flow measurement systems are supplemented by hydrostatic or ultrasonic level measurements.
-
product
Radiator Flow Test Machine
8601
The Radiator Flow Test Machine P/N 8601 meets all requirements of military specification MIL-F-45955A (AL). It is completely self contained and requires only connection to a source of shop electrical power to place in operation. A power cable complete with three prong grounding plug is permanently attached to the machine for this purpose. The unit consists of a water storage tank, a pumping system, a flow measuring system, a support and workstation, and the required hose adapters for connection to different size radiators. The complete unit is mounted on swiveling casters. The flow rate is infinitely adjustable from 0 to 120 gallons per minute by means of a panel mounted control valve. The machine is constructed from heavy 10 gauge steel, is double welded and is coated externally and internally with a water-resistant epoxy coating. Flow measurement is accomplished by a digital panel meter with a calibrated accuracy of plus or minus 3 percent of scale between 5 and 120 gallons per minute. Higher flows available on request.
-
product
Research Flow Cytometry
Flow cytometry is a powerful technique used to quantitively measure individual cells and other particles in suspension, at the rate of thousands of cells per second. Most commonly used in the context of Immunology, we have also started to see the adaption of flow cytometry for environmental studies, extracellular vesicle analysis, and the ability to use upwards of 30+ different parameters for more comprehensive analysis. Agilent flow cytometers offer excellent capabilities, high quality data, and an easy to use platform to save researchers time when acquiring and analyzing data. experiments.
-
product
Gas Flow Meters & Controllers
Accurate Mass Flow Measurement Sierra designs and manufactures a wide range of today's most advanced analog and digital gas flow meters, mass flow meters, controllers and switches across three core technologies: Capillary Thermal, Immersible Thermal, and Mass Vortex. Each gas flowmeter or controller meets exacting standards, and we can also customize your flow rate sensor to meet application requirements (often free of charge).
-
product
Flow Meter
V-Cone
The V-Cone Flow Meter is an advanced differential pressure instrument, which is ideal for use with liquid, steam or gas media in rugged conditions where accuracy, low maintenance and cost are important. With its DP built-in flow conditioning design, the V-Cone is especially useful in tight-fit and retrofit installations in which the long runs of straight pipe required by Orifice Plates, Venturi Tubes, and other technologies are either impractical or unavailable.
-
product
Hydraulic Flow Measurement
ND2
The new electronic NDW 2 inclinometer utilises a modern measurement method based on MEMS technology for gravitational inclination measurement (rotational angle measurement).
-
product
Flow Sensors
In flow measurement, the amount of material that flows through a certain pipe cross section per time unit is measured.
-
product
Radar Flow Meter
HR.FSL-1
HighReach Measuring & Controlling System Co.,Ltd
It is designed for combination with water flow detection for hydrological monitoring. It is designed for surface flow monitoring of natural rivers, canals/cules/pipes, etc., and flood monitoring in urban Seasons Flood, SUCH AS Low-lying Areas. Water Flow, Flow Rate Monitoring Drain, etc. of The Product Planar absorbs The 24GHz Radar Technology of a microstrip InnoSenT of Germany, and Adopts ITS own Back-End Processing Technology to Accurately The Water Extract Flow Speed , which can realize non-contact and unmanned automatic monitoring.
-
product
Flow Leak Testers
If you need high-quality air flow testers, you’ve come to the right place. We carry equipment for mass flow and leak testing, laminar flow, and continuous flow. You have the option of choosing touch screen or standard digital. All our equipment is compact and includes high-performing, state-of-the-art technology. Begin testing your equipment with our premium-grade flow testing equipment. Explore our amazing selection of flow testing equipment.
-
product
Mass Flow Controllers for Gases
Sensirion''s mass flow controllers are characterized by fast and accurate control of gas flow over a wide dynamic range. Based on the innovative CMOSens Technology, the heart of these mass flow controllers is a calorimetric microsensor (MEMS), which is integrated with the complete signal conditioning electronics on one single chip. While the flow is measured using the thermal measurement principle, efficient control is provided by an analog controlling circuit. This unique integrated technological approach results in excellent performance and reliability - at a very attractive cost.
-
product
M2730 DIGITAL PORTABLE FLOW CALIBRATOR
M2730 is the new digital portable calibrator of ForTest® M series. Enclosed in a container of anodized aluminium with shatterproof plexiglass front, we find a completely new circuit board and a mass flow meter sensor, for direct measurement of leaks. Coupled to the micrometer nozzle supplied, they are designed to simulate the desired leakage, facilitating the procedure for programming and verification of leak test instruments.
-
product
Stopped-flow/quench Flow
QFM-4000.
A unique design enables the QFM-4000 to trap and identify reaction intermediates. The device is also commonly used for analysing enzymatic reactionq, DNA cleavage or single turnover reactions.





























