Humidity
-
product
Digital Hygro-thermometer With Clock Alarm Function
KM 918A
Kusam Electrical Industries Limited
• Temperature range : -10 ~ 60°C / (14 ~ 140°F)• Temperature accuracy : ± 1°C / (± 1.8°F)• Temperature resolution : 0.1°C / °F• Humidity range : 20% RH ~ 95 % RH• Humidity resolution : 1 % RH• Humidity Accuracy : 8% RH• Clock, temperature and humidity display• Room temperature• Room Humidity display• Maximum or minimum memorization function• Alarm clock function at a desired hour• Power : Single 1.5V DC AAA battery
-
product
Multilogger
M1140
Universal datalogger with 4 hardware MiniDIN inputs for connecting temperature and humidity probes. Multilogger can be installed permanently to Ethernet network or work as portable device. Included is traceable calibration certificate in accordance with EN ISO/IEC17025.
-
product
Temperature Humidity Vibration Combined Environmental Test Chamber
Guangdong Bell Experiment Equipment Co.,Ltd
DGBell's Temperature Humidity Vibration Combined Test Chamber meets national standards and meets specific testing requirements. It is widely used in electrical and electronic products, automotive parts, materials, etc.
-
product
Medium Enterprise Environment Monitoring System
ENVIROMUX-5D
The ENVIROMUX-5D supports 5 external configurable sensors, 5 digital inputs, 2 output relays for control of external devices. The system also includes two internal sensors: temperature and humidity. It features 4 USB ports for USB modem, USB flash drive, or USB LCD screen. Linux inside.
-
product
Dial Indicators
1. Always select the dial test indicator that best fits the application.2. Care should be taken while using a dial test indicator, try not to jolt the indicator, should you be unfortunate and drop a dial test indicator, get it re-calibrated/repaired before reusing it.3. Replace worn contact points only with those of a similar length from the centre of the ball stylus to the abutment shoulder.4. Always clean dial test indicators after use with a lint free paper or cloth and store the indicator in its box or in a dust free area.5. When using a dial test indicator, always position the dial test indicator in a horizontal plane to the surface media.6. Always use a rigid stand for mounting the dial test indicator.7. When measuring a rotating object, either between centres or in a vee block, ensure that the object is rotating in the correct direction. Never rotate the workpiece towards the contact point.8. When measuring a sliding object, only take readings when the object is moving directly towards the contact point, never away from the contact point or in a sideways manner.9. Avoid parallax errors by reading the dial directly from the front and square on to the dial.10. Never oil a dial test indicator as this attracts contamination, should the movement become erratic then the dial test indicator should be submitted to a reputable repair agent.11. Try not to expose dial test indicators to direct sunlight or in a high humidity environment.12. Never use a dial test indicator that has not been calibrated, if in doubt consult an appropriate authority.
-
product
Damp-Heat Tester
King Design Industrial Co., Ltd.
1. Technical index:*Power: 380V, 3-, 50/60HZ 110A*Temperature range: 50°C~120°C*Humidity range: 20%~95% RH*Accuracy: 1) temperature ± 0.3°C;2) humidity ± 2.5% RH*Uniformity: 1) temperature ± 2.0°C;2) humidity ± 3.0% RH*Uniformity test: measured at T=85°C, RH=85%; set 9 points for temperature measurement and 2 points for humidity.*Inner wall is above 50 cm; within 20 min after temperature/humidity meets the setting value, the distribution uniformity of temperature/humidity can meet the aforesaid requirement.
-
product
CO2 Concentration Transmitter
H5424
The regulators are designed for online measurement of temperature (C or F), relative humidity and carbon dioxide concentration of air without aggressive ingredients. Measured temperature and relative humidity are recomputed to following humidity expression: dew point temperature, absolute humidity, specific humidity, mixing ratio and specific enthalpy.
-
product
Relative Humidity Kelvin Probe
RHC
The Relative Humidity Kelvin Probe (RHC) systems are the ideal solution for monitoring samples in a controlled atmosphere for contact potential difference (CPD)/work function (Φ) measurements.
-
product
CompactPCI 3U Module
CPCI-1553-DDC
Operating temperatureCommercial: 0 to +55 °COptional: -25°C to +80°C• Non-operating: -40°C to 85 °C• Airflow requirement: .5 CFM• Humidity: 5 to 90% (non-cond.)• Altitude: 0 to 10’000 ft
-
product
Calibrating Equipment
Stability DC : < 0.01 %FS / 3 min, AC : < 0.02 %FS / 3 minRipple : < 0.2 %Power Supply : 230 VAC, 50 (60) HzPower Consumption : < 250 VAOperating Temperature : 5ºC to 35ºCRelative Humidity : ≤ 80 %Distortion : < 0.5 %Display : 51/2 Digit LED Digital DisplayStep adjustment of Output Signal : 100 %FS / N, 10 %FS / N,%FS / N, 0.1 %FS / N (N = 4, 5, 6, 10 and 15)Dimensions : 190mm (H) x 480mm (W) x 545mm (D)Total Weight : 22.5 kgs (approx.)
-
product
Thermo Hygrometer & Hygro Anemometer
This instrument is a portable easy use and compact digitalThermo-Hygrometer designed for simple one handoperation. It uses thermistor as temperature sensor, and adigitalized humidity sensor as the hygrometer sensor withexcellent long term stability
-
product
Temperature & Humidity Testing
Trialon routinely test products for the automotive, military, medical, aerospace, heavy truck and customer markets in our facilities in Michigan and Indiana.
-
product
Resistors
A passive two-terminal electrical component that implements electrical resistance as a circuit element. In electronic circuits, resistors are used to reduce current flow, adjust signal levels, to divide voltages, bias active elements, and terminate transmission lines, among other uses. High-power resistors that can dissipate many watts of electrical power as heat may be used as part of motor controls, in power distribution systems, or as test loads for generators. Fixed resistors have resistances that only change slightly with temperature, time or operating voltage. Variable resistors can be used to adjust circuit elements (such as a volume control or a lamp dimmer), or as sensing devices for heat, light, humidity, force, or chemical activity.
-
product
Thermometer Hygrometer Data Logger
S3120
Data logger is designed for record of temperature and humidity. Values are stored to a non volatile electronic memory. Data transfer to the personal computer for further analysis is performed via USB, RS232, GSM or Ethernet interface by means of a proper communication adapter.
-
product
Sulphur Dioxide Test Chambers
The Sulphur Dioxide Test Chambers from Weiber are Corrosion Test Chambers used for testing the corrosion resistance of metallic surfaces and outer protective layer of coatings. They are used to create a highly corrosive environment rich in corrosive gases and natural humid conditions to induce accelerated corrosion in protective coatings of machines and equipments, electrical items, electronic parts and components, mechanical constructions, automobile and aircraft parts and components etc. Since the corrosive action of Sulphur dioxide also depends on specific temperature and humidity conditions and the presence of other contaminants, the Weiber Sulphur Dioxide Test Chambers are designed to create optimal conditions of temperature and humidity and also make provisions for introducing impurities and contaminants. These equipments operate across a wide temperature range, creating variations in the working temperature to mimic a natural weathering environment.
-
product
UV Accelerated Weathering Testers
Dongguan Amade Instruments Technology Co., Ltd
UV accelerated weather tester is also well known as UV test chamber, which is a type of environmental test chamber using fluorescent UV as light source to determine the resistance of plastics, leathers, rubbers, fabrics and so on to weathering under the specified conditions. We know that Ultraviolet light only accounts for 7% of the total sunlight, but it plays a core role in deterioration of materials. Not only does the ultraviolet, but UV test machine also can simulate dewing, high temperature, high humidity, black environment to be reappeared as a circulation. So UV weathering test is an essential measure for people to research and know the degradation state of specimens in advance as the time goes on.
-
product
Thermo-Hygrometer
C3121-2
Thermometer, hygrometer is designed for direct measurement of temperature, relative humidity.
-
product
Drug Stability Test Chamber
Sanwood Environmental Chambers Co ., Ltd.
If you want find complete details about Integrated drug stability test chamber, Drug stability test chamber, Chemical drug stability test chamber, New designed integrated drug chamber, Good quality integrated drug test chamber - China Sanwood Environmental Chambers Co., Ltd. The scientific method to create a drug for a long time to failure evaluation of stable temperature, humidity and light environment for pharmaceutical enterprises to accelerate drug test, long-term test, high humidity and strong light test, is the best choice for pharmaceutical companies and drug stability test program.
-
product
3 Axis Magnetic Field Meters
Display: 4 digits LCD, maximum reading 9999 Range: 20/2000 mG,2/20/200TResolution: 0.1/1 mG or 0 .001/0 .01/0 .1 TAccuracy: (2.5%+5dgt) at 50Hz/60Hz (5.0%+5 dgt) at 30Hz-2000HzSensor: Triple AxisFrequency response: 30Hz to 2000HzOperating temperature & humidity: 5'Cto 40'C, below 80% RHWeight: About 230g
-
product
Indicators
Watlow Electric Manufacturing Company
Watlow''s temperature and process indicators are ideal for displaying measurements of temperature and other process variables; such as flow, pressure and relative humidity. They are moisture resistant and include bright, four-character LED displays, user-selectable temperature units, sensor break protection, agency approvals including UL®, CE, RoHS compliance and multiple mounting options such as DIN-rail or panel mount configurations.
-
product
Interchangeable Probe Active Transmitters
HD2717T… Series
The instruments of the HD2717T… series are transmitters, indicators, and ON/OFF regulators with data logging functions, they measure temperature and humidity.
-
product
SparkFun Atmospheric Sensor Breakout
BME280 (with Headers)
The SparkFun BME280 Atmospheric Sensor Breakout with Headers is the easy way to measure barometric pressure, humidity, and temperature readings all without taking up too much space. Basically, anything you need to know about atmospheric conditions you can find out from this tiny breakout. The BME280 Breakout has been designed to be used in indoor/outdoor navigation, weather forecasting, home automation, and even personal health and wellness monitoring.
-
product
Criterion Temperature & Humidity Benchtop Chambers
BTL-433
The Criterion temperature/humidity chamber series provides an economical and space-saving solution for a variety of testing requirements. The chamber's interior size is 3.5 inches wider than traditional benchtops, yet the exterior is 20% narrower. The BTL-433 model uses 115V power, meaning no special power hook-ups.
-
product
Temperature and Humidity Transmitter
T3319-2
Humidity, temperature probe on a cable. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy.
-
product
Mini-Test Station
Mini-Test Station for low current fuel cell testing. The test station includes Analog mass flow controllers for Anode and Cathode gas streams, humidity bottles with preheaters and temperature controllers and a cell temperature controller. The test station is designed to use the customer's Potentiostat to load the cell. Manual backpressure is provided for pressures from 0-60 psig. The Mini-Test station is basically our Analog Mass Flow Controlled Low Flow Humidification System with all the options.
-
product
Outdoor Nodes
The upgraded Outdoor Nodes have been developed by the NITLab team and support MIMO operation. The new version of the Outdoor Nodes are equipped with 802.11a/b/g and 802.11a/b/g/n wireless interfaces. They also feature 2-core Intel cpus, new generation solid state drives and usb web cameras. Last but not least, each node is equipped with light, temperature and humidity sensors.
-
product
Load Cell Amplifier
Xiamen Elane Electronics Company, Ltd
: 0-50 degrees. Humidity: 30 to 80 percent, non-condensing.Power Supply Requirements:Power Supply voltage: 9 volts DC.Operating current: 5mA, plus bridge current.Bridge Input:Excitation voltage: 5 volts.Bridge Type: Full Wheatstone Bridge.Voltage Output Range: From 0 volts to 4.3 volts.
-
product
Web Sensor
P8552
The devices are equipped with two connectors for connection of the temperature and humidity external probes and three binary inputs for two-states signals. The dry contact or two-state voltage signal can be connect to the binary input.
-
product
Battery Test Chambers
Our battery test chambers are equipped with safety features conforming to industry safety standards enabling testing to a variety of conditions and specifications including extreme temperature cycling, humidity, vibration, and/or altitude. Russells Technical Products battery test chambers are used in a wide range of battery testing applications including lithium ion, battery packs, lead acid batteries, modules and more.