IEPE
standard for accelerometers.
-
product
IEPE Triaxial Accelerometer – 1000 mV/g
HDWBV-100
IEPE tri-axial accelerometer for the measurement of vibration transmitted to whole body.
-
product
PCB High Sensitivity, 100mV/g, ICP® (IEPE) Accelerometer
784170-01
The PCB HSTA15 helps you acquire sound and movement data with supported PXI Sound and Vibration Modules, C Series Sound and Vibration Input Modules, and USB-based Sound and Vibration Devices. This sensor uses the Integrated Electronics Piezo-Electric (IEPE) current excitation. The PCB HSTA15 features a sensitivity range of 10 mV/g and requires a 4-socket plug-to-3 BNC plug cable.
-
product
IEPE Triaxial High Sensitivity Accelerometer 10V/g
HDBV-1000
HDBV-1000 is a tri-axial accelerometer for the measurement of human exposure to whole-body vibrations, according to ISO 2631 and ISO 8041.
-
product
IEPE Signal Conditioning Amplifiers
Although IEPE (Integrated Electronics Piezoelectric) sensors is not a new technology there are a wide variety of applications where the measurement instrumentation is not configured with IEPE signal conditioning built in. In these situations it is necessary for the IEPE supply to be provided by an external source. Usually this type of instrument will also provide th user with the option to add gain to the signal being conditioned. The Kemo range of IEPE signal conditioning instruments can be used as stand alone conditioners/amplifiers are many of them can also be integrated with filters.
-
product
IEPE Monoaxial Accelerometer – 100 mV/g
HDP352C34
Monoaxial accelerometer general purpose, ICP, 100mV/g, weight 5,8 g, range 50 g pk
-
product
PXI Sound and Vibration Module
PXI Sound and Vibration Modules are designed specifically for applications like audio test and measurement, noise and vibration diagnostics, machine condition monitoring, automotive test, noise, vibration, and harshness(NVH) analysis, and laboratory research. They provide software-configurable AC/DC coupling, antialiasing filters, and IEPE conditioning to ensure precision measurements with microphones, accelerometers, and other transducers with large dynamic ranges.
-
product
NI-9234, 4-Channel, 51.2 kS/s/channel, ±5 V, C Series Sound and Vibration Input Module
779680-03
4-Channel, 51.2 kS/s/channel, ±5 V, C Series Sound and Vibration Input Module - The NI‑9234 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The NI‑9234 is also compatible with smart TEDS sensors. The NI‑9234 delivers a wide dynamic range and incorporates software-selectable AC/DC coupling and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. When used with NI software, this module provides processing functionality for condition monitoring such as frequency analysis and order tracking.
-
product
NI-9234 and cDAQ-9171 USB Sound and Vibration Measurement Bundle
865664-01
NI-9234 and cDAQ-9171 USB Sound and Vibration Measurement Bundle - The USB Sound and Vibration Measurement Bundle with NI-9234 and cDAQ-9171 includes the NI-9234 C Series Sound and Vibration Input Module and the cDAQ-9171 CompactDAQ Chassis for sound and vibration measurements. This bundle provides a portable, USB-based sensor measurement system that helps you measure signals from integrated electronic piezoelectric (IEPE) and non IEPE sensors such as accelerometers, tachometers, and proximity probes. The included NI-9234 features 4 channels with built-in anti-aliasing filters that automatically adjust to your sample rate. Additionally, when used with NI software, the bundle provides processing functionality for condition monitoring such as frequency analysis and order tracking.
-
product
NI-9230, 3-Channel, 12.8 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module
783824-02
3-Channel, 12.8 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module - The NI‑9230 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The NI‑9230 is also compatible with smart TEDS sensors. The NI‑9230 incorporates software-selectable AC/DC coupling, IEPE open/short detection, and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. When used with NI software, this module provides processing functionality for condition monitoring such as frequency analysis and order tracking.
-
product
PC USB Noise & Vibration Measurement Systems
IEPE Sensor Based Measurement Systems, Charge Amplifier Based Measurement Systems, All-in-One Integrated Vibration Measurement Systems
-
product
IEPE Triaxial Accelerometer – 1000 mV/g
HDP356B18
Triaxial accelerometer high sensitivity, ICP, 1V/g, weight 25g, range 5 g pk
-
product
PCB IMID01, 100 mV/g, IEPE, 2-Pin, Accelerometer, Industrial Vibration Sensor
784175-01
The PCB IMID01 is an industrial Vibration Sensor designed for permanent installations. This sensor helps you acquire sound and movement data with supported PXI Sound and Vibration Modules, C Series Sound and Vibration Input Modules, and USB-based Sound and Vibration Devices. The PCB IMID01 features a sensitivity range of 100 mV/g and uses the Integrated Electronics Piezo-Electric (IEPE) current excitation. The sensor supports the IMI Industrial Accelerometer Cable as well as the MIL2M-Breakout Cable.
-
product
NI-9230, 3-Channel, 12.8 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module
783824-01
3-Channel, 12.8 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module - The NI‑9230 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The NI‑9230 is also compatible with smart TEDS sensors. The NI‑9230 incorporates software-selectable AC/DC coupling, IEPE open/short detection, and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. When used with NI software, this module provides processing functionality for condition monitoring such as frequency analysis and order tracking.
-
product
Signal Conditioners
Metra Mess- und Frequenztechnik in Radebeul e.K.
Metra has been manufacturing amplifiers for piezoelectric transducers for over 50 years. We offer economic charge amplifiers and signal conditioners for IEPE transducers including microphones.
-
product
PCB GPTC03, 10 mV/g, IEPE, Accelerometer, General-Purpose Vibration Sensor
780988-01
The PCB GPTC03 helps you acquire sound and movement data with supported PXI Sound and Vibration Modules, C Series Sound and Vibration Input Modules, and USB-based Sound and Vibration Devices. This sensor uses the … Integrated Electronics Piezo-Electric (IEPE) current excitation. The PCB GPTC03 features a sensitivity range of 10 mV/g and requires a low-noise coaxial cable.
-
product
PXIe-4480, 1.25 MS/s, 3.4 Hz AC/DC-Coupled, 6-Input PXI Sound and Vibration Module
784277-01
1.25 MS/s, 3.4 Hz AC/DC-Coupled, 6-Input PXI Sound and Vibration Module—The PXIe‑4480 is designed for high-bandwidth audio, acoustic, and vibration measurements. It provides six channels of dynamic signal acquisition, and you can use one of four gain settings to configure your input range. The PXIe‑4480 also includes software-configurable AC/DC coupling, charge measurement, voltage excitation, IEPE excitation, and TEDS support, making it ideal for measuring acoustic transducers, pressure sensors, and hydrophones. Common applications include audio test; noise, vibration, and harshness (NVH) analysis; and underwater acoustic measurements. For measuring sudden changes, such as high speed blast and pressure events, the PXIe-4480 can sample up to 20 MS/s per channel in time-domain mode.
-
product
PXIe-4497, 204.8 kS/s, 114 dB, 2 Gains, AC/DC-Coupled, 16-Analog Input PXI Sound and Vibration Module
781369-01
204.8 kS/s, 114 dB, 2 Gains, AC/DC-Coupled, 16-Analog Input PXI Sound and Vibration Module - The PXIe‑4497 is designed for high‑channel‑count sound and vibration applications. With 24-bit analog inputs and IEPE constant current signal conditioning, the PXIe‑4497 is ideal for making precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. The PXIe‑4497 delivers simultaneous sample on all channels. In addition, the module includes built-in antialiasing filters that automatically adjust to your sample rate, software-selectable input gain, and TEDS smart sensor support for error-free setup. Common applications include noise, vibration, and harshness (NVH) analysis; large microphone arrays; and dynamic structural test.
-
product
Charge Amplifier
ZET 440
Charge amplifier ZET 440 for piezoelectric detectors is intended for:*amplification and conversion of output signals of primary piezoelectric transducers with charge output;*amplification and conversion of output signals of primary transducers with the IEPE type in-built electronics to voltage;*gain ratios: 1, 10, 100;*LPF: 0.1, 1, 10 Hz
-
product
Impulse Hammers/Impedance Heads
Impulse hammer excite from the smallest of structures to various civil engineering structures. The Dytran model 5800SL is an ultra miniature IEPE impulse hammer used to excite structures or machinery with a definable impulse force in modal and structural analysis of very light structures and impulse testing of very low mass, high resonant frequency components.
-
product
NI-9250, 2-Channel, 102.4 kS/s/ch Simultaneous, ±5 V, C Series Sound and Vibration Input Module
783827-01
2-Channel, 102.4 kS/s/ch Simultaneous, ±5 V, C Series Sound and Vibration Input Module - The NI‑9250 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers and microphones. The NI‑9250 is also compatible with smart TEDS sensors. The NI‑9250 delivers a wide dynamic range and incorporates software-selectable AC/DC coupling and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. When used with NI software, this module provides processing functionality for condition monitoring such as frequency analysis and order tracking.
-
product
NI-9232, 3-Channel, 102.4 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module
782000-02
3-Channel, 102.4 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module - The NI‑9232 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The NI‑9232 is also compatible with smart TEDS sensors. The NI‑9232 incorporates software-selectable AC/DC coupling, IEPE open/short detection, and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. When used with NI software, this module provides processing functionality for condition monitoring such as frequency analysis and order tracking.
-
product
4-CH 24-Bit 128kS/s Dynamic Signal Acquisition USB 2.0 Module
USB-2405
The USB-2405 is a 24-bit high-performance dynamic signal acquisition USB module equipped with 4 analog input channels providing simultaneous-sampling at up to 128 kS/s per channel. The USB-2405 also features software selectable AC or DC coupling input configuration and built-in high precision 2 mA excitation current to measure integrated electronic piezoelectric (IEPE) sensors such as accelerometers and microphones.
-
product
PCB High Sensitivity, 100mV/g, ICP® (IEPE) Accelerometer
780989-01
The PCB HSTC33 helps you acquire sound and movement data with supported PXI Sound and Vibration Modules, C Series Sound and Vibration Input Modules, and USB-based Sound and Vibration Devices. This sensor uses the Integrated Electronics Piezo-Electric (IEPE) current excitation. The PCB HSTC33 features a sensitivity range of 100 mV/g and requires a low-noise coaxial cable.
-
product
NI-9231, 8-Channel, 51.2 kS/s/channel, -5 V to 5 V, C Series Sound and Vibration Input Module
783610-01
8-Channel, 51.2 kS/s/channel, -5 V to 5 V, C Series Sound and Vibration Input Module - The NI-9231 is a high-density sound and vibration module that can measure signals from integrated electronic piezoelectric (IEPE) and non-IEPE sensors such as accelerometers, tachometers, and proximity probes. It can perform the high dynamic range measurements necessary for modern measurement microphones and accelerometers and features simultaneous sampling. The NI-9231 incorporates both a TEDS input path and 2 mA of IEPE signal excitation source that can be turned on and off, removing the need for external sensor power and reducing the complexity of the data acquisition system.
-
product
Amplifier
AC-100
The voltage amplifier for connecting piezoelectric acceleration meters, microphones, and other primary voltage output transducers to FFT spectrum analyzers with the IEPE standard current output (ZET 017-U2, ZET 017-U8, A19-U2).
-
product
PCI-4462, 204.8 kS/s, 118 dB, 3.4 Hz AC/DC Coupled, 4-Input Sound and Vibration Device
779309-01
The PCI‑4462 is a high-accuracy data acquisition module specifically designed for sound and vibration applications. It provides simultaneous four-channel dynamic signal acquisition with six programmable gain settings for making high-accuracy, frequency-domain measurements. The PCI‑4462 also includes software-configurable AC/DC coupling and integrated electronic piezoelectric (IEPE) conditioning to ensure precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. Common applications for dynamic signal acquisition devices include audio test; automotive test; noise, vibration, and harshness (NVH) analysis; and machine condition monitoring.
-
product
PCB TA01, 5 mV/g, IEPE, Accelerometer, Triaxial Vibration Sensor
780990-01
5 mV/g, IEPE, Accelerometer, Triaxial Vibration Sensor - The PCB TA01 helps you acquire sound and movement data with supported PXI Sound and Vibration Modules, C Series Sound and Vibration Input Modules, and USB-based Sound and Vibration Devices. This sensor uses the Integrated Electronics Piezo-Electric (IEPE) current excitation. The PCB TA01 features a sensitivity range of 5 mV/g.
-
product
PXIe-4464, 204.8 kS/s, 119 dB, 6 Gains, AC/DC-Coupled, 4-Input PXI Sound and Vibration Module
783087-02
204.8 kS/s, 119 dB, 6 Gains, AC/DC-Coupled, 4-Input PXI Sound and Vibration Module—The PXI‑4464 delivers simultaneous sampling on all channels. In addition, the PXI‑4464 includes built-in antialiasing filters that automatically adjust to your sampling rate, six software-selectable input gains ranges, and TEDS smart sensor support for error-free setup. The IEPE excitation circuit can deliver current for high-power sensors and strong data integrity over long sensor cable runs.
-
product
Condition Monitoring
MVX & MV-120
The MVX and MV-120 are powerful and intelligent, real-time, multi-channel data analyzers. The MVX and MV-120 gather multiple data-types, including vibration, IEPE, and voltage, in real-time, giving you the power to stop machine failures before they happen.
-
product
Compact IEPE Sensor Interface
Plug.n.DAQ Lite
ROGA Instruments Plug.n.DAQ Lite is a compact IEPE sensor interface for linux or windows with 2 input channels. It offers the USB PC interface and requires no drivers for installation. The operating system such as LINUX or Windows recognizes the device as an external usb audio card.





























