IEPE
standard for accelerometers.
-
Product
Special Accelerometers
-
Metra Meß- und Frequenztechnik Radebeul GmbH & Co. KG
This page shows vibration sensors for special applications.The Seat Pad Accelerometer Model KS963B100-S was developed for measuring whole body vibration transmitted by driver seats of building machines and other vehicles in compliance with ISO 10326-1 and ISO 7096. The sensor has an IEPE output for robust signal transmission.
-
Product
Hardware
-
Metra Meß- und Frequenztechnik Radebeul GmbH & Co. KG
*Compact measuring modules *Connect two IEPE accelerometers to your PC*USB-Interface facilitates installation*No settings necessary*Power supply via USB
-
Product
ECAT MiniModules
AD4 ECAT MM Series
-
Designed specifically for use with IEPE sensors. With up to 100 kHz per channel, the high-speed EtherCAT® measurement modules simplify your application.
-
Product
IEPE Triaxial High Sensitivity Accelerometer 10V/g
HDBV-1000
-
HDBV-1000 is a tri-axial accelerometer for the measurement of human exposure to whole-body vibrations, according to ISO 2631 and ISO 8041.
-
Product
PCI-4461, 204.8 kS/s, 118 dB, 3.4 Hz AC/DC Coupled, 2-Input/2-Output Sound and Vibration Device
779307-01
Sound and Vibration
The PCI‑4461 is a high-accuracy data acquisition module specifically designed for sound and vibration applications. It provides simultaneous two-channel dynamic signal generation and simultaneous two-channel dynamic signal acquisition with six gain settings to configure the input range. The PCI‑4461 also includes software-configurable AC/DC coupling and integrated electronic piezoelectric (IEPE) conditioning to ensure precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. Common applications include audio test; automotive test; noise, vibration, and harshness (NVH) analysis; and machine condition monitoring.
-
Product
PXI Sound and Vibration Module
Sound and Vibration
PXI Sound and Vibration Modules are designed specifically for applications like audio test and measurement, noise and vibration diagnostics, machine condition monitoring, automotive test, noise, vibration, and harshness(NVH) analysis, and laboratory research. They provide software-configurable AC/DC coupling, antialiasing filters, and IEPE conditioning to ensure precision measurements with microphones, accelerometers, and other transducers with large dynamic ranges.
-
Product
PXIe-4492, 204.8 kS/s, 113 dB, 2 Gains, 0.5 Hz AC/DC-Coupled, 8-Input PXI Sound and Vibration Module
781490-01
Sound and Vibration
204.8 kS/s, 113 dB, 2 Gains, 0.5 Hz AC/DC-Coupled, 8-Input PXI Sound and Vibration Module - The PXIe‑4492 is designed for sound and vibration applications. With 24-bit analog inputs and IEPE constant current signal conditioning, the module is ideal for making precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. The PXIe‑4492 delivers simultaneous sample on all channels. In addition, it includes built-in antialiasing filters that automatically adjust to your sample rate, software-selectable input gains, and TEDS smart sensor support for error-free setup. Common applications include noise, vibration, and harshness (NVH) analysis; large microphone arrays; and dynamic structural test.
-
Product
128 KS/s, 24-Bit, 8-Ch PCIE Card For IEPE Sound And Vibration
PCIE-1803
Sound and Vibration
8 simultaneously sampled analog inputs, up to 128 kS/s24-bit resolution ADCs with -102 dB total harmonic distortion plus noise (THD+N)
-
Product
8-CH 24-Bit High-Resolution Dynamic Signal Acquisition Module
PXIe-9529
Signal Module
The ADLINK PXIe-9529 is a high-performance, high density, 8-CH analog input dynamic signal acquisition module. The PXIe-9529 features eight 24-bit simultaneously sampling analog input channels. The 24-bit sigma-delta ADC provides a sampling rate of 192 kS/s at high resolution, making it ideal for higher dynamic range signal measurement. All channels are sampled simultaneously and accept input range up to ??10V, and the analog inputs support software-selectable AC or DC coupling and 4 mA bias current for integrated electronic piezoelectric (IEPE) sensors. The module is especially designed to meet the requirements of vibration analysis and audio testing.
-
Product
EMX-4XXX Product Family
-
The EMX-4xxx product family contains high-performance breakout boxes (EMX-4008 and EMX-4016), smart high density dynamic signal analyzers (EMX-4250 and EMX-4251), smart PXIe 625 KSA/s 4-channel digizers (EMX-4350), and charge and IEPE PXIe 625 KSA/s 4-channel digitizers (EMX-4380).
-
Product
Condition Monitoring
MVX & MV-120
-
The MVX and MV-120 are powerful and intelligent, real-time, multi-channel data analyzers. The MVX and MV-120 gather multiple data-types, including vibration, IEPE, and voltage, in real-time, giving you the power to stop machine failures before they happen.
-
Product
NI-9230, 3-Channel, 12.8 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module
783824-02
Sound and Vibration
3-Channel, 12.8 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module - The NI‑9230 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The NI‑9230 is also compatible with smart TEDS sensors. The NI‑9230 incorporates software-selectable AC/DC coupling, IEPE open/short detection, and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. When used with NI software, this module provides processing functionality for condition monitoring such as frequency analysis and order tracking.
-
Product
PXIe-4464 , 204.8 kS/s, 119 dB, 6 Gains, AC/DC-Coupled, 4-Input PXI Sound and Vibration Module
783087-01
Analog Input Module
204.8 kS/s, 119 dB, 6 Gains, AC/DC-Coupled, 4-Input PXI Sound and Vibration Module—The PXI‑4464 delivers simultaneous sampling on all channels. In addition, the PXI‑4464 includes built-in antialiasing filters that automatically adjust to your sampling rate, six software-selectable input gains ranges, and TEDS smart sensor support for error-free setup. The IEPE excitation circuit can deliver current for high-power sensors and strong data integrity over long sensor cable runs.
-
Product
NI-9234, 4-Channel, 51.2 kS/s/channel, ±5 V, C Series Sound and Vibration Input Module
779680-01
Sound and Vibration
4-Channel, 51.2 kS/s/channel, ±5 V, C Series Sound and Vibration Input Module - The NI‑9234 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The NI‑9234 is also compatible with smart TEDS sensors. The NI‑9234 delivers a wide dynamic range and incorporates software-selectable AC/DC coupling and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. When used with NI software, this module provides processing functionality for condition monitoring such as frequency analysis and order tracking.
-
Product
MINITAURs - 8-channel universal DAQ system
MINITAUR-S
-
Mixed signal 8-channel data acquisition system and multichannel data logger with cutting-edge technology at an attractive price. Universal analog inputs can accommodate various signals like strain gage, IEPE, voltage, current, RTD, thermocouple, and LVDT.
-
Product
NI-9232, 3-Channel, 102.4 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module
782000-01
Sound and Vibration
3-Channel, 102.4 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module - The NI‑9232 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The NI‑9232 is also compatible with smart TEDS sensors. The NI‑9232 incorporates software-selectable AC/DC coupling, IEPE open/short detection, and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. When used with NI software, this module provides processing functionality for condition monitoring such as frequency analysis and order tracking.
-
Product
IEPE Triaxial Accelerometer – 1000 mV/g
HDP356B18
-
Triaxial accelerometer high sensitivity, ICP, 1V/g, weight 25g, range 5 g pk
-
Product
PCB High Sensitivity, 100mV/g, ICP® (IEPE) Accelerometer
780989-01
-
The PCB HSTC33 helps you acquire sound and movement data with supported PXI Sound and Vibration Modules, C Series Sound and Vibration Input Modules, and USB-based Sound and Vibration Devices. This sensor uses the Integrated Electronics Piezo-Electric (IEPE) current excitation. The PCB HSTC33 features a sensitivity range of 100 mV/g and requires a low-noise coaxial cable.
-
Product
PCI-4462, 204.8 kS/s, 118 dB, 3.4 Hz AC/DC Coupled, 4-Input Sound and Vibration Device
779309-01
Sound and Vibration
The PCI‑4462 is a high-accuracy data acquisition module specifically designed for sound and vibration applications. It provides simultaneous four-channel dynamic signal acquisition with six programmable gain settings for making high-accuracy, frequency-domain measurements. The PCI‑4462 also includes software-configurable AC/DC coupling and integrated electronic piezoelectric (IEPE) conditioning to ensure precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. Common applications for dynamic signal acquisition devices include audio test; automotive test; noise, vibration, and harshness (NVH) analysis; and machine condition monitoring.