Insertion Loss & Return Loss
-
Product
Ethernet/AFDX/BroadR-Reach PXI Fault Insertion Switch - 4 Channel
40-201-004
Fault Insertion Unit
This high bandwidth differential fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
Product
PXI Dual Bus 64-Chan 2A Fault Insertion Switch
40-190B-102
Fault Insertion Unit
The Dual Bus, 64 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
Battery Fault Insertion Unit
Fault Insertion Unit
The Battery Fault Insertion Unit (FIU) provides intelligent switching of cell-simulation channels for the Battery Simulator 1200. The switching capability enables simulation of open-circuit and short-to-rail fault conditions on any cell channel for the purposes of battery management system (BMS) testing. Additionally, a four-wire auxiliary input allows you to connect an external digital multimeter (DMM) instrument to any cell channel for very high-accuracy bypass current and cell voltage measurements. Each FIU provides 24 independently-programmable cell-switching channels for one or two 12-cell Battery Simulator 1200 units. Additional Battery Simulator 1200 and FIU instruments can extend functionality up to 120 series-connected cell channels.
-
Product
Optical Return Loss Meter
ORL
-
•Four functions in one•Power meter and light source•Return loss meter and insertion loss meter•3 wavelength detection(1310/1490/1550nm)•Rugged, shock and water-proof for field use•Compact size, lightweight and cost-effective•Quick and easy to operate
-
Product
PXI 22-Channel 2A Fault Insert Switches
40-202-001
Fault Insertion Unit
This is the 22 Channel version of the 40-202 Fault Insertion Switch. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test.
-
Product
PXI Fault Insertion Switch, 6-channel, Two Fault Buses, 10 A, Hardware Interlock
40-192A-012-HI
Fault Insertion Unit
The 40-192A-012-HI is a PXI fault insertion switch with hardware interlock using solid state switching elements and is capable of switching current up to 10A. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test:
-
Product
Signal, Module Insert, Receiver, i2 MX, 84 Position, QuadraPaddle, Crimp
510143002
Receiver Module Insert
Signal, Module Insert, Receiver, i2 MX, 84 Position, QuadraPaddle, Crimp.
-
Product
Signal, Module Insert, ITA, i2 MX, TriPaddle ,33 Position
510144006
ITA Module Insert
Signal, Module Insert, ITA, i2 MX, TriPaddle ,33 Position.
-
Product
High Speed Insert, Receiver/ITA, SIM, VTAC, Retention Insert
610151105
SIM Insert
The miniature size of the SIM PCB Adapter greatly benefits from the addition of the VTAC Retention Insert. The VTAC Retention Insert helps to provide rigidity and reinforce the connections between 610151103 and 610151104. Works with Right Angle VTAC.
-
Product
Micro Power, Insert, ITA, SIM, 2 Pos, 2 Slot
510181102
SIM Insert
This insert contains 2 micropower contacts and is part of the Infinity Connector system. It is used in the 90 Series SIM Module and occupies 2 of the 34 slots in this module.
-
Product
PXI 5A Fault Insertion Switch 20-Chan 2-Bus
40-198-002
Fault Insertion Unit
The 40-198 is a 20 Channel Fault Insertion switch, primarily designed for the simulation of fault conditions in automotive/avionics applications involving the reliability testing of safety critical controllers.
-
Product
PXI Single Bus 74-Ch 2A Fault Insertion Switch
40-190B-001
Fault Insertion Unit
The Single Bus, 74 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
Signal, Insert, Receiver, QuadraPaddle, SIM, Pass-Thru, 4 Pos, 1 Slot
510180105
SIM Insert
Signal, Insert, Receiver, QuadraPaddle, SIM, Pass-Thru, 4 Pos, 1 Slot.
-
Product
Micro Power or Micro Coax, Insert, Receiver, SIM, 2 Pos, 2 Slot (not loaded)
510180104
SIM Insert
Not loaded. Micro Power or Micro Coax patchcords need to be purchased separately.
-
Product
QuadraPaddle Signal Insert, ITA, SIM, 4 Position (not Loaded- For Discrete Wiring Only)
510181101
SIM Insert
QuadraPaddle Signal Insert, ITA, SIM, 4 Position (not loaded- for discrete wiring only)
-
Product
PXI Single Bus 32-Ch 2A Fault Insertion Switch, N/O Through Relays
40-190B-501
Fault Insertion Unit
The Single Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
VTAC, Insert Bundle, Receiver/ITA, SIM, Right Angle and Pass-Thru
610151106
SIM Insert
VTAC, Insert Bundle, Receiver/ITA, SIM, Right Angle and Pass-Thru.
-
Product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 3-Channel
42-203-001
Fault Insertion Unit
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
Product
Tool, Vertical Insertion, VTAC, ICon
910112135
Insert Kit
Tool, Vertical Insertion, VTAC, iCon
-
Product
PXI Fault Insertion Switch, 7-Channel, One Fault Bus, 20 A, Hardware Interlock
40-193A-001-HI
Fault Insertion Unit
The 40-193A-001-HI is a 7-Channel Fault Insertion switch with hardware interlock and one fault bus, designed for the simulation of fault conditions in automotive systems. The module is capable of switching current up to 20A.
-
Product
Loss Test Set, Return Loss Test Set
LTS1315, LTS1315R
-
The KD Optics LTS1315 is a combined mains / battery powered laser source and power meter designed to make attenuation testing in the field easy, reliable and most importantly, consistent. The LTS1315R incorporates return loss measurement (RLM) capability with the ability to switch very easily between dBrel and return loss.
-
Product
Signal/Mini Power/ Mini Coax, Module Insert, ITA, i2 MX, TriPaddle, 8/8 Position
510144005
ITA Module Insert
Signal/Mini Power/ Mini Coax, Module Insert, ITA, i2 MX, TriPaddle, 8/8 Position
-
Product
Single Bus 75-Channel 2A PCI Fault Insertion Switch
50-190-001
Fault Insertion Unit
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
Product
PXI/PXIe Fault Insertion Switch, 64-Chan 2A, N/C Through Relays, Fault Buses on M & U
40-190C-112
Fault Insertion Unit
The 40-190C-112 (PXI) and 42-190C-112 (PXIe) are fault insertion switches with 64 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
Blank Insert Kit, Receiver/ITA, SIM, VTAC, 10 Pieces
610151102
Insert Kit
Blank inserts are for unused VTAC module slots. One blank insert fills 1 slot in a VTAC insert-compatible module.
-
Product
48-Ch 2A-250VAC 2-Bus Fault Insertion
YAV90076
Fault Insertion Unit
48 channels2A 250V 2 Fault Insertion BusesSwitching up to 60CAN Control (or Ethernet with Ethernet to CAN Gateway)Drivers dll & VIs available
-
Product
Dual Bus 36-Channel 2A PCI Fault Insertion Switch
50-190-202
Fault Insertion Unit
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
Product
Signal, Module Insert, Receiver, i2 MX, 84 Position, QuadraPaddle, Fully Loaded w/ Twin Female Contacts (p/n 610138200)
510143003
Receiver Module Insert
Signal, Module Insert, Receiver, i2 MX, 84 Position, QuadraPaddle, Fully Loaded w/ Twin Female Contacts (p/n 610138200)
-
Product
PXI/PXIe Fault Insertion Switch, 64-Chan 2A, N/C Through Relays, Fault Buses on M & U
42-190C-112
Fault Insertion Unit
The 40-190C-112 (PXI) and 42-190C-112 (PXIe) are fault insertion switches with 64 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
Optical Return Loss (ORL) Meter
OPTOWARE-S300 (FOTS-ORL Meter Systyem)
-
The Optical Return Loss(ORL) Meter is an efficient system for the characterization and test of optical components and systems to be performed in high quality.