Insertion Loss & Return Loss
-
Product
Bench-top 12 Cores Or 24 Chanels MPO/MTP Insertion Loss & Return Loss Tester
-
Anfkom International Co.,Limited
This test station do the auto-testing on 12 core(24 core) for insertion loss and return loss, highly efficient multi-core fiber insertion and return loss measurement and make high precision on the measurement result with OTDR mandrel free technical adopting.
-
Product
Insertion Loss & Return Loss Test Station
-
Anfkom International Co.,Limited
High sensitivity, large dynamic rangeDual channelsFor lab&manufacturing optic testing
-
Product
12/24 CH Insertion Loss/Return Loss Automatic Testing System
CA3201
-
UC INSTRUMENTS CA3201 12/24 CH INSERTION LOSS/RETURN LOSS AUTOMATIC TESTING SYSTEM is special designed for MPO/MTP fiber cable and multi-channel fiber optical devices like PLC device. It also can be easy changed into AWG DWDM devices testing system ifwe change 1310 /1550 nm light source into UC INSTRUMENTS’ tunable laser source.
-
Product
Test Services
-
D-Coax offers RF/Microwave test services for your researchprojects, as well as, production quantities tests. We have available resources and expertise in the high frequency interconnects testing that will benefit your research and products. We will work with you to make your requested tests the most accurate and reliable and we'll complete them in a timely fashion. The following parameters can be characterized or tested to specifications with our test services: Time Domain: Impedance, Impedance profile, rise time, propagation delay, skew and more. Frequency Domain: S21 - Insertion loss, S11- Return loss, S12 - Reverse Insertion loss (port 2 insertion loss), S22 - Reverse Return loss (port 2 return loss) and more.
-
Product
Signal, Insert, Receiver, QuadraPaddle, SIM, Pass-Thru, 4 Pos, 1 Slot
510180105
SIM Insert
Signal, Insert, Receiver, QuadraPaddle, SIM, Pass-Thru, 4 Pos, 1 Slot.
-
Product
VTAC, Insert, Receiver/ITA, SIM, Vertical Header, 8 Pos
610151107
SIM Insert
The VTAC vertical header insert contains 8 VTAC high speed contacts and is designed to mount directly to a PCB. It can be configured as a backplane connector and daughterboard connector. Also sold as a set with 610151108.
-
Product
Combo Test Lead Kit
U8201A
Insert Kit
Designed for use with U3606A DMM | DC power supply; includes leads, probes, alligator clips, SMT grabbers, and banana plugs
-
Product
PXI Fault Insertion Switch, 6-channel, Two Fault Buses, 10 A, Hardware Interlock
40-192A-012-HI
Fault Insertion Unit
The 40-192A-012-HI is a PXI fault insertion switch with hardware interlock using solid state switching elements and is capable of switching current up to 10A. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test:
-
Product
Signal, Module, ITA, i2 MX, 84 position, QuadraPaddle, Crimp
510144002
ITA Module Insert
Signal, Module, ITA, i2 MX, 84 position, QuadraPaddle, Crimp
-
Product
Signal/Micro Power/ Micro Coax, Module Insert, Receiver, TriPaddle, i2 MX, 9/9 Position
510143004
Receiver Module Insert
Signal/Micro Power/ Micro Coax, Module Insert, Receiver, i2 MX, TriPaddle ,9/9 Position.
-
Product
PXI Fault Insertion Switch, 7-Channel, One Fault Bus, 20 A, Hardware Interlock
40-194A-001-HI
Fault Insertion Unit
The 40-194A-001 is a 7-Channel PXI Fault Insertion switch with hardware interlock and one fault bus, designed for the simulation of fault conditions in automotive systems. As well as high current handling of 20A, very low currents can also be switched.
-
Product
64-Ch 1-Bus Fault Insertion
YAV91082
Fault Insertion Unit
64 channels 1 thread 2A 250V 1 Fault Insertion Buses Switching up 60W CAN Control (or Ethernet with Ethernet to CAN Gateway) Drivers dll & VIs available
-
Product
Dual Bus 36-Channel 2A PCI Fault Insertion Switch
50-190-202
Fault Insertion Unit
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
Product
PXI Fault Insertion Switch, 7-Channel, Two Fault Buses, 20 A, Hardware Interlock
40-193A-002-HI
Fault Insertion Unit
The 40-193A-002-HI is a 7-Channel Fault Insertion switch with hardware interlock and two fault buses, designed for the simulation of fault conditions in automotive systems. The module is capable of switching current up to 20A.
-
Product
PXI 30A Fault Insertion Switch 6-chan 2-bus
40-191-012
Fault Insertion Unit
The 40-191-012 is a PXI fault insertion switch using solid state switching elements and is capable of carrying 40A on single channel or 30A on all channels at the same time and provides a robust solution to high current fault insertion.
-
Product
20/26 Ghz Coax, Module Insert, ITA, i2 MX, 5 Position
510144008
ITA Module Insert
20/26 Ghz Coax, Module Insert, ITA, i2 MX, 5 Position.
-
Product
Insertion / Return Loss Tester
JW8301
-
Shanghai Joinwit Optoelectronic Tech,co.,Ltd
JW8301 Insertion/Return Loss Test Station is a professional instrument, which is designed for CWDM device, multi-wavelength devices, PLC, fiber cable. It is a new high precise optical test instrument, which combines many years experiences of passive device ,configured with VFL and 850nm Optical Light Source. It supports the judgment of threshold, Multi wavelength automatic testing, system integration, upper computer monitor solution etc.
-
Product
Micro Power or Micro Coax, Insert, ITA, SIM, 2 Pos, 2 Slot (not loaded)
510181104
SIM Insert
Not loaded. Micro Power or Micro Coax patchcords need to be purchased separately.
-
Product
Micro Power, Header Insert, Receiver/ITA, SIM, Right Angle, 2 Pos, 2 Slot
510181103
SIM Insert
This header insert contains 2 right-angle micropower contacts and is designed for soldering directly to a PCB as part of the Infinity Connector system. It is used in the 90 Series SIM Module and occupies 2 of the 34 slots in this module.
-
Product
Signal, Insert Bundle, ITA, QuadraPaddle, SIM, Right Angle and Pass-Thru
510181107
SIM Insert
Signal, Insert Bundle, ITA, QuadraPaddle, SIM, Right Angle and Pass-Thru.
-
Product
PXI 10GBase-T1 Ethernet MEMS Fault Insertion Switch, 8 Channel
40-205-008
Fault Insertion Unit
The 40-205-008 (PXI) is a 8-channel fault insertion switches designed to simulate common faults on high speed two wire communication interfaces such as xBaseT1 Ethernet. They available with 4 or 8 channels of two wire serial connections and can be used for simulating faults on 10BaseT1, 100BaseT1, 1000BaseT1 and 10GBaseT1 Ethernet interfaces. Any wire can be set as open circuit and shorts can be applied across wire pairs. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to supply voltage or ground.
-
Product
Ethernet/AFDX/BroadR-Reach PCI Fault Insertion Switch - 8 Channel
50-201-008
Fault Insertion Unit
This high bandwidth differential PCI fault insertion card is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This card supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground.
-
Product
VTAC, Insert, Receiver/ITA, SIM, Pass-Thru, 8 Pos, 1 Slot
610151103
SIM Insert
VTAC, Insert, Receiver/ITA, SIM, Pass-Thru, 8 Pos, 1 Slot VTAC inserts are reversible and can be used as a Receiver or ITA insert.VPC's revolutionary high speed VTAC insert contains 8 gold-plated, self-aligning contacts and is designed to reduce crosstalk. With a data transfer rate of more than 12.5 Gbps per differential pair and a cycle life of over 150,000, VTAC has set the standard for high speed interconnect solution requirements. Sold in individual quantities.Use with VPC's right angle VTAC insert (p/n 610151104) or VPC's vertical header (p/n 610151107) to connect directly to a PCB.
-
Product
Module Insert, Blank, I2 MX, ITA
510143007
ITA Module Insert
This blank module insert can be used to fill a blank position in the i2 MX ITA.
-
Product
PXI Fault Insertion Switch, 7-Channel, One Fault Bus, 20 A
40-194A-001
Fault Insertion Unit
The 40-194A-001 is a 7-Channel PXI Fault Insertion switch with one fault bus, designed for the simulation of fault conditions in automotive systems. As well as high current handling of 20A, very low currents can also be switched.
-
Product
Ethernet/AFDX/BroadR-Reach PXI Fault Insertion Switch - 8 Channel
40-201-008
Fault Insertion Unit
This high bandwidth differential PXI fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
Product
PXI 5A Fault Insertion Switch 5-Channel
40-196-101
Fault Insertion Unit
The 40-196 is a 10 Channel 5A Fault Insertion Switch, primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert different fault conditions between the test fixture and the equipment under test: Open-Circuit, Short-Circuit between signal pairs, Short-Circuit between signal pairs and user applied fault conditions e.g. Power or GND. Shorting relays on each channel enable UUT signals to be subjected to external user applied fault conditions or to be shorted to the adjacent signal in the same channel. Relays in line with the signal allow open circuit conditions to be simulated on either side or both sides of a channel signal pair. The switching topology of the 40-196 allows channels to be interconnected so that complex fault insertion systems can be constructed.
-
Product
PXI 5A Fault Insertion Switch 10-Channel
40-196-001
Fault Insertion Unit
The 40-196 is a 10 Channel 5A Fault Insertion Switch, primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert different fault conditions between the test fixture and the equipment under test: Open-Circuit, Short-Circuit between signal pairs, Short-Circuit between signal pairs and user applied fault conditions e.g. Power or GND. Shorting relays on each channel enable UUT signals to be subjected to external user applied fault conditions or to be shorted to the adjacent signal in the same channel. Relays in line with the signal allow open circuit conditions to be simulated on either side or both sides of a channel signal pair. The switching topology of the 40-196 allows channels to be interconnected so that complex fault insertion systems can be constructed.
-
Product
PXI 10A Fault Insertion Switch 10-Chan 2-Bus
40-199-002
Fault Insertion Unit
The 40-199 is a 10 Channel Fault Insertion switch designed for the simulation of fault conditions in automotive/avionics applications, involving the reliability testing of safety critical controllers.
-
Product
Pin Insertion Tool For Scorpion Connectors With Crimp Pins
C020AFR-2CP-2A-I
Insert Tool
Extractor tool for crimp pins fitted into a Scorpion connector housing.