Resistance Standards
See Also: Resistance, Resistivity, Resistance Meters, Resistance Test
-
product
Panel-mount Type Resistivity Meter (Four-Wire Transmission, 2-channel)
HE-960RW
HE-960RW connects resistivity sensor(ERF sereies) and measures resistivity and temperature in the sample water.This resistivity meter is ideal for such applications as the high-precision water monitoring employed at ultra-pure water plants used in semiconductor manufacturing.They utilize newly designed, high-precision, high-stability temperature measurement circuitry and a vastly improved temperature compensation function, an important element for measuring the resistivity of ultra-pure water.
-
product
Battery Internal Resistance Tester
TOB-R-203
Xiamen Tob New Energy Technology Co., Ltd
Battery internal resistance tester used for lithium battery, lead-acid battery, Ni-Cd/Ni-MH battery and all kinds of batteries.
-
product
Micro-Ohmmeter and Loop Resistance Tester
LRT 6000
LRT 6000: The right solution for impedance resistance measurement in compliance with all aircraft specifications on plane, helicopter, rocket, army vehicles for both production andmaintenance. It is a very easy-to-use and versatile instrument. Its ergonomics allow the user to use it either placed on the ground or across one's shoulder or chest. Awide back-lit LCDdisplay combinedwith an intuitive keyboard ensures simple and easy operation.
-
product
Standard Gain Horn Antenna
KSHA-BJ260-25-2.92L
Standard Gain Horn Antenna, Frequency21.7~33GHz, Gain 25dBi, Linear Polarization, 2.92-Female
-
product
Standard 2.00 (57.00) - 3.60 (102.00) General Purpose Probe
P2664G-2R1S
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 10Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 114Full Travel (mm): 2.90Recommended Travel (mil): 84Recommended Travel (mm): 2.13Overall Length (mil): 895Overall Length (mm): 22.73Overall Length Remark: Tip 1C: 845 mil (21.46 mm) Tip 2R: 935 mil (23.75 mm)
-
product
Standard Tests
The following list contains only the most important standards and does not claim to be complete.EN 60204-1 Electrical equipment of machinesEN 60335-1 Electrical appliances for household and similar useEN 50106 Sampling test, routine tests (in conjunction with EN 60335-1)EN 60598-1 LuminariesEN 60601-1 Medical electrical equipmentEN 60730-1 Automatic electrical controlsEN 61010-1 Measuring, control and laboratory equipmentEN 61439-1 Switch cabinet and switchgearEN 62368-1 Equipment for audio/video, information and communication technologyEN 62841-1 Hand-held electric toolsEN 50191 Erection and operation of stationary and non-stationary electrical test equipmentLVD Low V oltage D irective _
-
product
20J3 SHEET RESISTANCE METER
Non-contact measurement of Ohms/sq, Ohms-cm, resistivity, thickness, and moreMeasures nearly all thin conductive materials or coatingsChoose a sensor in one of four ranges, from .005 Ohms/sq to 100,000 Ohms/sqadd other sensors laterFor benchtop or inline applicationsSimple one-button operationSmall footprint with detached sensor probeOptions include vacuum-ready probe, PC-based productivity software, Ethernet connectivity, stage, and more
-
product
Intex Beam Gauge & Standard Contacts
Developed to measure both internal and external diameters and lengths, the Intex gauge's aluminium extrusion beam gives it a rigid yet lightweight quality, making it ideal for shop-floor environments. The simple release of a locking thumbscrew enables the gauge's measuring direction to be changed quickly and easily.
-
product
Non-Contact (Pulse-Voltage Excitation Method) Ultra-Low Sheet Resistance Measurement System
PVE-80
*No damage measurement by non-contact Pulse-Voltage excitation method*Easy to measure & carry around, Removable stage plate*Easy operation and data processing by PC with Software*Measurement result can shown by 3 types of measurement unit (Sheet resistance[Ohm/Sq], Electric conductivity[S/cm], Electrical conduction[S])*Pulse-Voltage excitation method : Pat. No.5386394 Joint development with Chiba Univ.
-
product
Standard 1.90 (53.90) - 8.00 (226.80) High Frequency Probe
CSP-40L-013
Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Full Travel Remark: Shield: 275 (6.99) including travel of probesRecommended Travel (mil): 133Recommended Travel (mm): 3.38Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,151Overall Length (mm): 29.24
-
product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4E
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
product
Standard 1.55 (44.00) - 3.20 (91.00) General Purpose Probe
HPA-50T
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 590Overall Length (mm): 14.99
-
product
Standard Voltage 37 Pin D-Type Connector Blocks
The connector blocks and breakouts below are not compatible with Pickering products, however, are offered for developing a connection solution for use with other products.
-
product
Hydrogen Frequency & Time Standard
CH1-1007
Hydrogen frequency and time standard Ch1-1007 is designed to generate and reproduce precision, highly stable, spectrally pure frequency and time signals. Main areas of application: – in metrology when transferring the sizes of units of frequency and time, including as part of mobile measuring complexes; – in radio astronomy when conducting scientific research; - in radio navigation when working as part of automated measuring systems and complexes.
-
product
Standard 0.39 (11.00) - 1.39 (39.00) Replaceable General Purpose Probe
MEP-30J
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 30Test Center (mm): 0.76Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 690Overall Length (mm): 17.53
-
product
Multi-Test Resistivity Measurement System
Sheet resistance mapping of thin films with a collinear 4-point probe, Temperature co-efficient of resistance (TCR) of thin films with collinear 4-point probe, Precision temperature co-efficient of resistance (TCR) with 2-point Kelvin probes and precision surface temperature probe, resistor testing with 2-point Kelvin probes,Precision resistor testing with a Kelvin probe card, temperature co-efficient of resistance resistor test (TCR), and Standard TCR test of multiple resistors with Kelvin probes or a probe card.
-
product
Standard 2.90 (82.20) - 5.40 (153.00) Switch Probe
TSP157-H200-1
Current Rating (Amps): 10Average DC Resistance lower than (mOhm): 20Test Center (mil): 157Test Center (mm): 3.99Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 984Overall Length (mm): 25.00Switch Point (mil): 67Switch Point (mm): 1.70
-
product
Rubidium/GPS Frequency Standard
PXIe-3352
The Astronics Test Systems PXIe-3352 frequency standard module sets a new standard for high density functionality in a PXI module by combining a Rubidium oscillator with a GPS receiver into a single, compact instrument.
-
product
Standard Gain Horn Antenna
ZLB7-600-700-1846
Standard Gain Horn Antenna, Frequency0.6~1GHz, Gain10dBi, Power 200W, WR1150, Flange FDP8, Linear polarization, N type Female connector
-
product
Radius, Standard 0.61 (17.00) - 2.80 (79.00) General Purpose Probe
HPA-0D
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13
-
product
Standard 0.79 (23.40) - 1.75 (49.60) General Purpose Probe
HPA-40C
Current Rating (Amps): 2Average Probe Resistance (mOhm): 35Test Center (mil): 39Test Center (mm): 1.00Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 660Overall Length (mm): 16.76
-
product
Dytronic Primary Transfer Ultra Stable Standard
RD-22 Ultra
The RD-22 Dytronic Primary Transfer Ultra Stable Standard represents the state-of-the-art technology in a commercially available AC transfer reference. The Ultra Stable RD-22 is a variant of the RD-22 Primary Transfer Standard that has been optimized for 120/240 V @ 5A operation to provide optimum stability. In a stable test environment, repeatability for a 10-second test of ±0.6 µWh/VAh is attained at 120 V and 240 V at 5A inputs with a 95% confidence interval. A typical experimental 2 repeatability of less than ±0.25 µWh/VAh is achieved. In a stable test environment, a reproducibility of ±2 µWh/VAh over a five-day interval is attained at 120 V and 240 V at 5A inputs with 95% confidence interval.
-
product
High Precision Battery Internal Resistance Instrument
BT-9562
High-precision measurement of battery internal resistance and voltage.
-
product
Standard 0.30 (8.50) - 1.06 (30.00) Battery Probe
BIP-3
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 60Recommended Travel (mm): 1.52Mechanical Life (no of cyles): 250,000Overall Length (mil): 511Overall Length (mm): 12.98
-
product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2J40
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2C30
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
product
1KV Insulation Resistance Tester
2680
Shenzhen Chuangxin Instruments Co., Ltd.
1KV insulation resistance tester
-
product
Standard Voltage 9 Pin D-Type Cables - Calibration Cables for Pickering