Reference Standards
See Also: References, Reference Antennas, Reference Decoders, Reference Jumpers, Reference Sources, Reference Transformers, Reference Transmitters, Acoustical References, Frequency References, Solar Reference Cells
-
product
Standard Test Systems
WaveCore™ Products
Textron Systems’ WaveCore family offers a variety of standard test systems with a primary application of satellite payload lab testing. Our systems can be deployed affordably for both production and engineering applications, providing industry-leading levels of data correlation with high system mean time between failures and low mean time to repair.
-
product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2F
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4J
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
product
Portable Three-Phase Energy Standard
PEWM-3C
The three-phase energy standard PEWM-3C is used for quick on-site tests of all types of electricity meters – for active, reactive or apparent energy, two-, three- or four-wire connection. Three voltages and three currents are measured at the same time. The current can be measured either via direct connection up to 10A (class 0.1), or with three current clamps (CC) to 120A, 150A or 1000A (class 0.2).
-
product
Reference Magnets
Reference Magnets provide a stable and convenient method to verify the accuracy and calibration of Hall Effect Gaussmeters, Teslameters, and Probes.
-
product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25L18-4
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard Accessory Replacement Kit for PP017/PP018
PKIT4-5MM-101
Standard Accessory Replacement Kit for PP017/PP018.
-
product
Standard Resistor Oil Bath
9400
Measurements International Ltd.
Measurements International’s series of fluid baths are used for the maintenance of standard resistors and shunts. The 9400 has been designed after compiling years of customer feedback on existing resistor oil baths.
-
product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2C40
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35 Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
product
Industry Standard in Noise Measurement
PN9000
The PN9000 is a simple and fast Automatic Phase Noise Test System covering a very wide frequency range(2 MHz to 140 GHz). Its modular architecture allows optimum configuration, multiple measurement techniques and future growth in a compact instrument.
-
product
5G Channel Sounding, Reference Solution
The 5G Channel Sounding, Reference Solution is a combination of hardware, software, and measurement expertise providing the essential components to accelerate 5G sounding research. This reference solution enables researchers and design engineers to use, enhance, or modify the test platform as required to meet specific test application needs including scalable channel count, flexibility to transmit and measure in mmWave frequencies, wide transmit and analysis bandwidths, and real-time data processing.
-
product
Inductance Standard
1482 Series
The GenRad 1482 Standard Inductors are the standard of choice in metrology labs. Used today by national metrology institutes and primary standards bodies around the world, these inductors have no peer or equivlent.
-
product
NI Real-Time Test Cell Reference System
778820-35
DIAdem Advanced with DAC Bundle, Perpetual License, Include 1 Year SSP
-
product
Standard 1.09 (31.00) - 4.50 (128.00) Long Travel Bead Probe
BPLT-1C-4.5
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,450Overall Length (mm): 36.83Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, High Spring: 350 mil / 8,89 mm
-
product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3A
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Shunt Voltage References
Analog Devices offers a broad line of shunt precision voltage references that combine excellent accuracy and temperature stability with low noise and small packages. These devices operate in a manner that is functionally equivalent to a Zener diode. The bias current must be set higher than the sum of the maximum quiescent current of the voltage reference and the maximum expected load current. Since shunt voltage references are typically biased with a resistor, the voltage reference can operate on a wide range of input voltages.
-
product
Electronic AC Potential Standard
PMT25010
Power Measurement Technologies Inc.
Provides the electronic equivalent of a standard potential transformer as typically required for instrumentation potential transformer accuracy testing.
-
product
Standard 6.13 (174.00) - 16.00 (456.00) General Purpose Probe
EPA-5A
Current Rating (Amps): 8Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,420Overall Length (mm): 36.07
-
product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50B-QG-75
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,575Overall Length (mm): 40.00
-
product
Standard 1.53 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-72I40-4
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
product
Standard Voltage 9 Pin D-Type Connectors for Pickering
The connectors below are suitable to use with Pickering cards and modules that utilize a standard voltage 9-pin D-type connector.
-
product
Spectral Radiance / Luminance Calibration Standards
Standard lamps calibrated in luminance and spectral radiance. Traceable calibrations in the wavelength range from 250 nm to 2500 nm.
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1I8-4-S
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
RF Reference Sources
The 27 GHz 96270A and 4 GHz 96040A Low Phase Noise Reference Sources are designed specifically for RF calibration, featuring a calibration-oriented interface, precision signal level and attenuation, high signal purity and precision low distortion modulation. Both instruments simplify the process of RF calibration by reducing the amount of equipment and simplifying the calculations required.
-
product
Standard Mechanical Calibration Kit, DC To 9 GHz, 3.5 Mm
85033E
85033E Standard Mechanical Calibration Kit, DC to 9 GHz
-
product
300nA NanoPower Voltage References
ISL21080
The ISL21080 analog voltage references feature low supply voltage operation at ultra-low 310nA typ, 1.5µA max operating current. Additionally, the ISL21080 family features guaranteed initial accuracy as low as ±0.2% and 50ppm/°C temperature coefficient.
-
product
Standard Voltage 37-Pin D-Type Connector & Cable Accessories
The Standard Voltage 37-Pin D-Type connector is used on PXI switching products to provide a medium density connector solution.Connection solutions for modules with High Voltage Rating D-Type connectors are also available.
-
product
ACCUplace Macro Calibration Standard
AP-M Series
With both X & Y axis metric scales, these dual axis targets are ideal for calibrating optical magnification in microscopes, linear distance, stage motion and squareness. In addition, with the larger area calibration scale, the calibration of low power optical systems over the longer distances can be easily carried out. The AP-M is offered on two standard materials; Glass (CG) and Opal (OP).
-
product
Turbidity And Standard Meters
Accurately measure the cloudiness of a fluid caused by suspended particles with turbidity meters and standards from HF scientific. Our turbidity meters and standards instruments include features that simplify installation, maintenance, and data access.We offer reliable turbidity meters including an online turbidity meter, handheld turbidity meter, and benchtop turbidity meter.
-
product
Open Standard Module (OSM)
ROM-2860
Advantech ROM-2860 OSM 1.1 Computer-on-Module is powered by Qualcomm QCS6490/5430 SoC which includes up to Arm v8 Cortex® in combination with Andreo GPU 643 and Andreo VPU 633 graphics engine. It provides PCIe, USB 3.2, Giga Ethernet, MIPI-CSI, I2C, SPI, GPIO, PWM and eDP, DP, MIPI-DSI display for embedded applications.





























