product
Standard 0.62 (18.00) - 4.00 (114.00) Bead Probe
BTP-1C-4
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard Gain Horn Pyramidal Horn Antenna
Elva’s SGPH series of standard gain horn antennas cover the frequency range of 18 to 220 GHz in ten waveguide bands. They can be issued with rectangular or circular waveguide. Lens technology significantly allows decreasing mechanical sizes of horns and correcting beam for the best performance. These horns are ideal solution for measurement gain of other antennas, short range radars and radiometers.
-
product
Standard DIP Socket with Solder Tail Bifurcated Contacts
Series 511
Standard DIP Sockets with Wire Wrap Bifurcated Contacts. Features: Standard DIP sockets are available with solder tail or wire wrap pins, all with bifurcated contacts. Consult Data Sheet No. 12005 for wire wrap pins. Aries offers these standard DIP sockets in more sizes than any other manufacturer.
-
product
Standard 1.00 (28.00) - 3.20 (91.00) General Purpose Probe
P2550-6
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,453Overall Length (mm): 36.91Rec. Mounting Hole Size (mil): 126Rec. Mounting Hole Size (mm): 3.20Recommended Drill Size: #30 or 3.20 mm
-
product
800MM 31.5In Digital Level Bevel Gauge w/ LCD Backlight Screen, Level Bubbles IP54 Standards
DL411
Advance Plus Trading Co., Ltd.
Model Number: DL411 Key Specifications/Special Features: 800MM 31.5INCH Digital Level with level bubbles, 2 hand shanks, LCD bright backlight display, IP54 standards 1. 800mm 31.5inch level with 2 bubbles, 800*28*64mm(L*W*H), net weight: 700g;2. Resolution: 0.05°;3. Horizontal level measuring range: 0 to 360°;4. Accuracy: ±0.3°;5. Measures angle in degrees, IN/FT, mm/m, % slope or pitch;6. Audible tone at level, plump and setting angle;7. Automatic shut-off after 3 minutes;8. Backlight LCD;9. Self checking accuracy;10. Self calibration;11. Hold-function to freeze the measurement;12. Memory recall (9 measurements);13. 2pcs Handshanks design, easy to take and use;14. 2pcs high accuracy horizontal & vertical bubbles, clearly to check;15. Operated by DC 3V (2*LR03 AAA 1.5V batteries, not included); 16. IP54 waterproof & dusyproof industrial standard.
-
product
IEC60335 Standard Electrical Temperature Tester
CX-w15
Shenzhen Chuangxin Instruments Co., Ltd.
Standard Test corner/room conform to IEC60335-1:2004. and GB4706.1-2005. can be used to the temperaturetest of all kinds of electronic products supply, in conformity with the standards requirement of the environmental conditions.
-
product
Standard 4.47 (127.00) - 12.00 (340.00) High Frequency Probe
K-50B-S
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 2.50Nominal Impedance (Ohms): 50Test Center (mil): 600Test Center (mm): 15.24Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 90Recommended Travel (mm): 2.29Overall Length (mil): 1,205Overall Length (mm): 30.61
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1Z1-4-S
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 1.02 (29.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-62H-4
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Four Terminal Pair Standard Resistor Set
42030A
The 42030A is a standard resistor set consisting of nine precision resistor standards which range from 1 mΩ to 100 kΩ. These resistors are primarily used for performance tests of Keysight's 4-terminal pair LCR meters and impedance analyzers. Refer to the instrument's operation/service manual for the method of using these standards.
-
product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2B40
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74T65
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
product
Standard Magnetizers
The selection of a magnetizing system begins with an analysis of the production requirements, including magnet material, magnet size, magnetizing orientation, number of poles, production speed, magnet measuring, and other operations that are necessary. After careful evaluations of these factors, and reviews of samples and/or drawings, our application engineers can recommend a system that will meet your requirements.
-
product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4H
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
product
Standard 1.10 (31.00) - 3.85 (109.00)General Purpose Probe
SPA-64-7
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3: 0,365″; Tip 8: 0,385″; Tip ,9,10: 0,363″
-
product
Standard & Top Paint Inspection Gauges
121/4
is a hand-held paint gauge that offers a quick, versatile method of coating examination and measurement in a portable, easy-to-use format.
-
product
Micropower Voltage References
Analog Devices offers a broad line precision micropower voltage references with extremely low quiescent currents (series references) or minimum shunt currents (shunt voltage references). All of our precision voltage references offer excellent initial accuracy and low temperature drift over time and temperature. Our Reference Plus products combine precision voltage references with comparators or amplifiers.
-
product
Bloomy Simulation Reference System
The Bloomy Simulation Reference System provides a hardware in-the-loop (HIL) test environment for dynamic, closed-loop testing of many aerospace and transportation control systems. The reference system integrates the computing, I/O, and software components needed for standalone use or to form the basis of a more complex test system.
-
product
Standard & Custom Test Fixtures
Both standard and custom Test Fixtures from OAI enable the user to integrate the solar cell with the I -V tester. Fixture configurations range from from simple hold down devices to temperature-controlled fixtures with front and back side contact. We invite you to contact an OAI Application Engineer for help with your fixture design. With our expert guidance, you can expect maximum performance from your I -V Tester and Solar Simulator.
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1T24-4
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
The Standard R&D Wafer-Lifetime Tool
WCT-120
Best available lifetime measurement accuracy. Measure lifetime and surface recombination for a wafer of any quality or crystallinity.
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1H-4
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Remote Radio Head Test, Reference Solution
The Remote Radio Head Test, Reference Solution provides the physical interfaces together with the vector signal analysis and vector signal generation you need to carry out comprehensive functional and performance testing of your RRH). Fully characterize the uplink and downlink, RF air-interface to and from the digital "front-haul".
-
product
Ultra-Low Noise, Precision Voltage Reference
ISL21090
The ISL21090 is an ultra-low noise, high DC accuracy precision voltage reference with a wide input voltage range. The ISL21090 uses Renesas' advanced bipolar technology to achieve sub 1.0µVP-P (1.25V option) 0.1Hz to 10Hz noise with an initial voltage accuracy of 0.02% (2.5V option).
-
product
Standard 1.50 (43.00) - 3.00 (85.00) General Purpose Probe
P2665G-1R1S
Current Rating (Amps): 15Average DC Resistance lower than (mOhm): 10Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,290Overall Length (mm): 32.77Overall Length Remark: Tip 2W: 1270 mil (32.26 mm)
-
product
SIM, Module, ITA, 90 Series, Fully Loaded with pairs of VTAC Standard Pass-Thru and Right Angle Inserts (610151106)
510171102
This fully loaded SIM module kit comes with 34 pairs of VTAC Standard Pass-Thru and Right Angle Inserts (610151106). This kit also includes two PCB brackets for securing module to PCB.
-
product
Standard RF Power Sensors
Coaxial Dynamics "Standard" line of RF Power Sensors provide DC currents proportional to the forward and reflected power flowing through the line. All models are designed to drive a 30A, 1400-Ohm meter, or provide approximately 100 millivolts across a 5K load.
-
product
IEC-IEEE-CSA-IS Standards
MOTOMEA RDS Automatic IEC-60034-2-1 Test Bench solutions are complete turnkey systems and provide a full implementation of the IEC 60034-2-1, IEEE 112-2004, CSA C390-10 standards
-
product
A Global Standard for Acoustic Absorption Measurements
Alpha Cabin
The Alpha Cabin has been especially designed for the measurement of acoustic absorption properties of materials and components used for the noise insulation of vehicles. The Alpha Cabin is significantly smaller than normal reverberation rooms and therefore ideally suited to use within limited space capacities. The acoustic absorption of the Alpha Cabin itself is also very low: Thanks to the high level of sound insulation, background noise in the frequency range of interest is kept to a minimum.