Showing results: 1906 - 1920 of 2437 items found.

  • 3-Phase Programmable AC Source

    61700 - Chroma Systems Solutions, Inc.

    Power: 1500VA, 3 (61701); 3000VA, 3 (61702); 4500VA, 3 (61703); 6000VA, 3 (61704); 12000VA, 3 (61705)Voltage: 0~150V/0~300VFrequency: 15~1.2KHzPhase angle: 0~360Built-in PFC, provides input power factor over 0.98Advanced PWM technology delivers high power density in a compact rack-mountable packageBuilt-in output isolation relaysAC+DC output modeProgrammable slew rate setting for changing voltage (optional function)Turn on, turn off phase angle controlUser-definable power-on statusPower line disturbance (PLD) simulation capability (optional function)Comprehensive measurement capability: V, Irms, Ipk, I inrush, P, PF, CF of current etc.Programmable r.m.s. current limitFull protection: OP, OC, OV and OT protectionGPIB and RS-232C interface (optional)Easy-use software for operation

  • Earth Tester

    TAURUS PRECIOHM ET - Taurus Powertronics Systems

    The TAURUS PRECIOHM ET is one of the specially designed products by TAURUS to measure earth resistivity and earth resistance in a power station. These tests are performed based on 4 point (Wenner) and 3 point (fall of potential) methods respectively. All electrical equipment in the substation and power stations are electrically connected to station earth mat with earth electrodes. The earth electrode ensures that in the event over voltage on the system due to system fault or lighting discharges etc., the parts of the equipment which are normally ”dead” as far as voltages are concerned; do not attain dangerously high potentials. An earth electrode will only be effective so long it has a low resistance to the earth and can carry large currents without deteriorating. Thus the resistance of earth electrode should be low to give good protection and it must be continuously measured and monitored in all the substations and power stations.

  • Manual Flying Probe Test Systems

    atg Luther & Maelzer

    They provide flexible measurement technologies like Kelvin and high voltage tests in combination with low tooling costs. atg Luther & Maelzer offers a wide range of different systems starting from standard systems with 8 heads up to oversized systems with 24 test heads.

  • HV Rotary Switches

    B-1003 - ROSS ENGINEERING CORPORATION

    A key feature of our rotary switches is their simple mechanical design which results in conservative stress levels for trouble-free, long life use.  In addition, each rotary switch has a reinforced chassis design utilizing G-10 or G-11 fire retardant anti-tracking coated epoxy glass insulation.  G-7 silicone glass is used for special applications where RF or high temperatures are involved.  Heavy duty contacts, specifically designed to minimize corona in the Ross rotaries, are made of highly conductive yet weld resistant alloy with high contact closing force.  This high force gives our rotary switches high momentary current capability and a reputation for their ability to withstand high shock and vibration as well as other severe environmental conditions.  Ratings to 150kV, to 200A.  When immersed in insulating oil, fluid or gas, the voltage withstand value is at least doubled and the interrupt capability is much greater.  In a gas atmosphere, no modification is required. However, immersion in oil or fluid may require modification in some cases, at an extra cost (optional).  Each unit is either manually or electrically operated.  One SPDT contact is standard on most units.  The auxiliary contact is used as an interlock for protection against "Switching Hot".

  • Dry Arc Resistance Tester

    SCR ELEKTRONIKS

    Dry Arc Resistance Tester is designed to conduct high voltage,low current Arc Resistance test on solid electrical insulation material as per:ASTM standard D495-99 (2004) and UL 746A. Why Arc Resistance Test? Many Cases of insulator failure are due to deterioration of its surface because of sustained electrical discharge or Arc. This test method is intended to test the resistance of insulating material when a high -Voltage low -current Arc close to the surface of insulation, intending to form a conducting path therein or in causing the material to become conducting due to decomposition and erosion.AdvantagesThis Test ensures that your products meet high standards of quality & safety. This product is meant for all Switchgears/ insulator/ Polymer/ electro plastic manufacturers and manufacturers who use insulators in their products e.g. Wiring Accessories, Appliances, HT/LT line insulators etc.

  • LVDS (Low Voltage Differential Signaling) Drivers and Receivers

    Analog Devices Inc.

    LVDS (Low Voltage Differential Signaling) Drivers and Receivers from Analog Devices offers designers robust, high speed signaling for single-ended to differential solutions for point-to-point applications. Our selection of products conform to the TIA/EIA-644 LVDS standard and contain the first LVDS transceivers to meet 8 kV IEC ESD performance standards - important for robust, interboard applications where the connectors can be exposed to more harsh electrostatic environments. Companion differential line receivers and differential line drivers support up to 600Mbps. LVDS greatly improves noise immunity and minimizes emissions for high speed point-to-point data transmission and is a low power alternative to emitter-coupled logic (ECL) or positive emitter-coupled logic (PECL) signaling.

  • PXI/PXIe High Resolution Waveform Digitizer Family

    PXD(e)721x - VX Instruments GmbH

    The PXD(e)721x High Resolution Digitizer- Family features up to two 100MS/s simultaneously sampled input channels with 16 Bit resolution, input voltages up to ±60V and a bandwidth of 50MHz (100MHz with option DBW).Every digitizer channel has its own 2MB memory which allows up to 1 million samples. Depending on the amount of channels and the isolated option, the digitizers are built into a compact 3U PXI device for 1 or 2 slots. All isolated devices have a high common mode rejection ratio (CMRR). A great number of trigger capabilities results in multiple instrument and channel synchronization possibilities.Data can be acquired before and after the trigger event with a programmable sample counter, that controls the number of data points.

  • PXI 40Amp 14Volt 2xSPST Automotive Relay

    40-180-001 - Pickering Interfaces Ltd.

    Models 40-180/181 are High Power Relay Modules available with 2 SPST, 4 SPST or 2 SPDT contacts. They are capable of switching inductive/capacitive loads up to 40A at 14VDC or 20A at 28VDCThe 40-180/181 High Power Relay Modules are suitable for switching heavy loads or for slaving large external relays, contactors and solenoids. In particular these relay modules are designed for automotive test applications requiring the switching of D.C. voltage at high current. The 28V version is suitable for truck system test applications.

  • PXI 20Amp 28Volt 2xSPST Automotive Relay

    40-180-011 - Pickering Interfaces Ltd.

    Models 40-180/181 are High Power Relay Modules available with 2 SPST, 4 SPST or 2 SPDT contacts. They are capable of switching inductive/capacitive loads up to 40A at 14VDC or 20A at 28VDC.The 40-180/181 High Power Relay Modules are suitable for switching heavy loads or for slaving large external relays, contactors and solenoids. In particular these relay modules are designed for automotive test applications requiring the switching of D.C. voltage at high current. The 28V version is suitable for truck system test applications.

  • PXI 40Amp 14Volt 4xSPST Automotive Relay

    40-180-101 - Pickering Interfaces Ltd.

    Models 40-180/181 are High Power Relay Modules available with 2 SPST, 4 SPST or 2 SPDT contacts. They are capable of switching inductive/capacitive loads up to 40A at 14VDC or 20A at 28VDC. The 40-180/181 High Power Relay Modules are suitable for switching heavy loads or for slaving large external relays, contactors and solenoids. In particular these relay modules are designed for automotive test applications requiring the switching of D.C. voltage at high current. The 28V version is suitable for truck system test applications.

  • PXI 20Amp 28Volt 2xSPDT Automotive Relay

    40-181-011 - Pickering Interfaces Ltd.

    Models 40-180/181 are High Power Relay Modules available with 2 SPST, 4 SPST or 2 SPDT contacts. They are capable of switching inductive/capacitive loads up to 40A at 14VDC or 20A at 28VDC. The 40-180/181 High Power Relay Modules are suitable for switching heavy loads or for slaving large external relays, contactors and solenoids. In particular these relay modules are designed for automotive test applications requiring the switching of D.C. voltage at high current. The 28V version is suitable for truck system test applications.

  • PXI 20Amp 28Volt 4xSPST Automotive Relay

    40-180-111 - Pickering Interfaces Ltd.

    Models 40-180/181 are High Power Relay Modules available with 2 SPST, 4 SPST or 2 SPDT contacts. They are capable of switching inductive/capacitive loads up to 40A at 14VDC or 20A at 28VDC.The 40-180/181 High Power Relay Modules are suitable for switching heavy loads or for slaving large external relays, contactors and solenoids. In particular these relay modules are designed for automotive test applications requiring the switching of D.C. voltage at high current. The 28V version is suitable for truck system test applications.

  • PXI 40Amp 14Volt 2xSPDT Automotive Relay

    40-181-001 - Pickering Interfaces Ltd.

    Models 40-180/181 are High Power Relay Modules available with 2 SPST, 4 SPST or 2 SPDT contacts. They are capable of switching inductive/capacitive loads up to 40A at 14VDC or 20A at 28VDC.The 40-180/181 High Power Relay Modules are suitable for switching heavy loads or for slaving large external relays, contactors and solenoids. In particular these relay modules are designed for automotive test applications requiring the switching of D.C. voltage at high current. The 28V version is suitable for truck system test applications.

  • C Series Temperature Input Module

    NI

    The C Series Temperature Input Module features up to 16 channels of temperature input from either thermocouples or RTDS. This module can include anti-aliasing filters, open-thermocouple detection, and cold-junction compensation. Additionally, the module also feature isolation for safety, noise immunity, and high common-mode voltage range.The C Series Temperature Input Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.

  • DC Electronic Load

    M9822/M9822B - Lisun Electronics Inc.

    M9822/M9822B is newly designed circuit adopts rapid AD and DA technology to achieve rapid measurements with high accuracy. And the resolution of 0.1mV/0.1mA can effectively display the minor change of voltage and current, so the instrument has a wider application field and achieves better test results. Meanwhile your operation becomes much more comfortable and easy by equipping the high-light VFD, the simple menu and displayed contents and the operation state indicators on all keys. Otherwise the complete and humanized test functions will greatly improve your productivity.