Product
4-Ch Analog Output EtherCAT Slice IO Module
AMAX-5024
EtherCAT Slice IO Module
Channels: 4Output Type: V, mV, mAOutput Range: 0~5V, 0~10V, ±5V, ±10V, 4~20mA, 0~20mAResolution: 16-bit with accuracy, 0.01% FSR@25°CSlew Rate: ConfigurableDrift: ± 50 ppm/°CCurrent Load Resistor: Max. 500 ΩVoltage Load Resistor: Min. 1KΩ
-
Product
High Speed-Large Current DC Electronic Load (CC/CV/CR/CP)
PLZ-4WL Series
-
While the PLZ-4WL series succeeds to the superior operability of our conventional model of the PLZ-4W series, the PLZ-4WL series realizes the high speed rise and fall time (slew rate of 50A/µs.) in the range of low voltage with large current. The PLZ-4WL offers six operation modes, and equips with various features such as sequence operation, switching operation, soft-start function, and time and voltage measurement. The PLZ-4WL applies not only for the conventional load test of the CPU power supply, but also it can be applied to even faster current response test. In addition, the PLZ-4WL is a space-saving design (about 50% less volume of the conventional model) that can save the facility space of the testing site, and it can be applied for the single cell testing of the large scale rechargeable battery.
-
Product
Wireless Remote Control System
Hydra Set
-
Hydra SetPrecision Load PositionerInstalled between the crane (or hoist) and the load, Hydra Set is a valuable positioning device that enables the operator to place heavy objects from 1/2-ton (450 kgs.) up to 250 tons (227,000 kgs.) with 0.001 inch (0.025mm) precision.
-
Product
On Load Tap Changer Analyzer
TAP-4-PLUS
-
The Tap-4-PLUS is the newest instrument by Zensol for OLTC testing. It has 2 more analog inputs than the TAP-4. The TAP-4-PLUS with the TAP-DRM accessory can perform dynamic resistance, vibration, and motor current recordings at the same time. Doing so will allow you to easily understand the vibration impacts.
-
Product
Load Module for SLSC
Load Module
Bloomy's 8-Channel Load Module provides isolated current and voltage measurements for eight on-board 5W loads or for eight off-board 120W loads. With built-in switching for calibration and fault injection, the module provides unsurpassed capability for Mil/Aero applications. The module also provides switching and connections to allow switching between a real load (e.g., actuator, valve, etc.) and the simulated load.
-
Product
PXI SPST Power Relay: 20-ch, 5A, 300W
M9135A
SPST Switch
The M9135A is a general purpose switch with 20 independent, single-pole, single-throw (Form A) switches in a single PXI module. This module is ideal for switching heavy loads or power supplies including voltages mains or DC current. The heavy-duty armature relays are rated for up to 5A and 300W, enough for inductive or capacitive loads. Choose from the heavy-duty power connector or an unterminated power cable.
-
Product
Programmable DC Electronic Load
-
Programmable DC electronic load is a device that precisely regulates the load voltage and current dissipation power consumption of electrical energy. There are several important parameters to consider when choosing programmable DC electronic load, including maximum power, maximum current, maximum voltage, current slope, and so on. Each indicator is related to the needs and applications we actually test.
-
Product
Passive Probe, 10:1, 200 MHz, 2-Pack
N2140A
Oscilloscope Probe
The Keysight N2140A is an extremely low-cost passive probe that provides a switchable 10:1 / 1:1 attenuation and up to 200 MHz bandwidth. It features a high input resistance of 10 MΩ (switchable to 1 MΩ) to address a wide range of measurement needs with low probe loading. The probe can be adjusted for both low-frequency compensation and high-frequency compensation. For the best measurements, you should compensate your probe to match its characteristics to the oscilloscope. This probe is compatible with Keysight InfiniiVision Series oscilloscopes with 1 MΩ input.
-
Product
Power Supply
-
High precision analog control loop power supplies for inductive loads such as electromagnets, superconducting coils, Helmholtz coils and others.Autonomous analog power supplies with digital controls, readouts and supervision. The interfaces are digital and analog
-
Product
Load Optimization
CENTRAX CU series
-
A line of advanced, multifunctional heavy-current measurement devices and power meters that integrate programmable logic controller (PLC) capabilities into a single housing.
-
Product
Portable Electricity Meter Testers
EE-120A-3S
-
The EE-120A-3S unit consists of a three-phase energy standard class 0.1 and current load up to 120A. The unit performs testing of all types of electricity meters using the voltages of the network. The meter error can be measured for active, reactive or apparent energy in Manual Mode or with predefined Test Plans using the keyboard and the LCD display on the panel. Maximum Demand Test, Register Test, Starting Current Test and No Load Test can be performed too. The energy standard of the system can be used without the phantom load to test meters with customer load and perform analysis of the three-phase network – with direct measurement or with optional current clamps.
-
Product
PXI 10A Power MUX, 2-Bank, 8-Channel
40-661-102
Multiplexer Module
The 40-661 is a single pole power multiplexer module, suitable for switching inductive/capacitive loads up to 10A with 125VDC/250VAC hot switching and 400VDC/250VAC cold switching. The multiplexer is available in 8-bank 4-channel, 5-bank 6-channel, 4-bank 8-channel, 2-bank 16-channel and 1-bank 32-channel formats. Also, 4-bank 4-channel, 2-bank 8-channel and 1-bank 16-channel half density configurations are available. Signal connections are made via front panel mounted 20-way GMCT plugs.
-
Product
PXIe-4145, 4-Channel, ±6 V, 500 mA Precision PXI Source Measure Unit
782435-01
Source Measure Unit
PXIe, 4-Channel, ±6 V, 500 mA Precision PXI Source Measure Unit - The PXIe-4145 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation, and each channel has integrated remote (4 wire) sensing for accurate measurements. The fast sample rate of the PXIe-4145 can reduce measurement times, capture transient device characteristics, and allow quick I V characterization of devices under test (DUTs). With a high-speed sequencing engine, you can synchronize all these SMUs with each other or with other instruments such as switches or high-speed digital test modules. Additionally, you can tune the PXIe-4145 response to any load to achieve optimum responses with maximum stability and minimum transients using SourceAdapt technology.
-
Product
PXI Solid State Multiplexer, 5 Amp, Single 24-Channel, 1-Pole
40-652A-101
Multiplexer Module
The 40-652-101 is a single 24-channel, 1-pole MUX and is part of our range of multiplexers uses solid state relays with high tolerance to surge currents and hot switching events. These multiplexers provides an isolation relay in the common to minimize capacitive loading when expanding the multiplexer across multiple modules. The 40-652 can sustain 30A for 300µs on hot or cold switching.
-
Product
Platforms
-
The use of switching systems to route instrumentation and stimulus signals to appropriate test points on a unit under test has a very crucial role to play in most electronics test systems. The sharing of test resources, connection of calibration references, load management, and many other functions are all managed by the switching system, the switching system acts as the interface between the unit under test (UUT) and the test equipment.
-
Product
Unclamped Inductive Load Tester
ITC55100C
-
The system has been designed around a very powerful micro-controller that gives it a timing resolution of 40ns, twenty times faster than the previous model. Its response time to the peak and zero current is improved ten times. Combined this gives greater accuracy for the charging and avalanche times and for the reported peak drain current.
-
Product
Tensile Strength Tester
-
Capacity of Tester with accuracy of 100g : 250 Kgf. and 500 Kgf.Capacity of Tester with accuracy of 10g : 20 Kgf, 50 Kgf and 100 KgfS Type Load Cell fixed with Top GripTraverse Speed: 300 & 100mm /min.Grip Separation: 1000 mmGrip Separation: 25 mmTop Grip is fixed and Bottom Grip is Movable Type.Elongation measurement by Steel Scale and Digital Counter Meter Both.Digital Display of Load and Elongation.Peak value of last test can be read.User friendly key panel with switch of zero setting and peak value of last testMotor: 1/2 HP single phase 220V 50 Hz. ( for Capacity up to 100 Kgf )Motor: 1 HP single phase 220 V 50 Hz ( for Capacity up to 500 Kgf)Power: 220 V AC 50 Hz.Safety device by limit switch to protect from over traverse.
-
Product
PXI 6U Power Relay Module
-
The SPDT Power Relay Module consists of 48 single pole changeover relays controlled by a PXI/CompactPCI interface. It is suitable for applications were conventional reed-relay based switching modules do not have sufficient voltage rating or current carrying capacity. All 48 contacts are electrically isolated from each other and are capable of switching resistive and inductive loads up to 2000VA at 240V AC. The module is built on a single width 6U PXI module and the interface is via a standard PXI/CompactPCI backplane. Connection to the switching contacts is via three 50-pin D-type male connectors mounted on the front panel. These are machined contact types with 7.5A current carrying capacity.
-
Product
PXI Programmable Power Supply, 0-48VDC
41-743-001
Programmable Power Supply
The 41-743 is a fully isolated programmable power supply capable of delivering output voltages to 48V with a voltage setting resolution of less than 1mV. The output is capable of delivering up to 40W to the user load and requires no external power supply – power is drawn from two PXI backplane slots.
-
Product
WaveLink ProBus2 Platform/Cable Assembly for 4-8 GHz WaveLink Amplifiers.
WL-PBUS2
-
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
Product
Dynamic Jack System
-
This is a structural fatigue testing machine for researching the dynamic behavior of full-size or model structures by applying repeated loads. The actuator that supplies the loads to the specimens can be installed on load frames, reaction floors, reaction walls, etc.
-
Product
Sound Quality Meter
-
OROS Sound Quality Meter is a dedicated solution for calculating psycho-acoustics metrics for Sound Quality studies. A signal file can be simply loaded. The first initial step is to listen to the signal that has been recorded. The second stage is to select the required parameters and to compute them
-
Product
Towing Dynamoters
-
From light passenger cars to heavy commercial truck vehicles, you can turn to us for a solution that saves you time and money by easily and reliably measuring attributes under a range of simulated load conditions, negative slopes and positive slopes up to 25% – all in a safe, controlled environment. Look to Taylor as the industry leader for a record of pioneering valuable towing dynamometer (dyno) advancements including:
-
Product
E84 Handheld Tester
E84
-
The E84 Handheld Tester is the most efficient tool available for quickly testing, trouble-shooting, and resolving E84 problems. This self-contained, battery operated tool integrates the industry-leading automated load and unload routines provided in the E84 Emulator.
-
Product
Single 4x4 1-Pole 16 Amp PXI Power Matrix
40-552-001
Matrix Switch Module
The 40-552 range of 16 Amp PXI power matrix modules is available in four configurations with matrix sizes of 8x2 and 4x4 and the ability to expand the matrix size with the Y-Axis loop-thru connections: e.g. 8x4, 12x4, 16x4, etc. (with 4x4 matrices) or 16x2, 24x2, 32x2, etc. (with 8x2 matrices). This range is capable of switching up to 16 Amps and up to 300VDC/250VAC hot switching and 400VDC/250VAC cold switching. These PXI power matrix modules are intended for switching heavy AC or DC loads or for the slave switching of large external relays, contactors, and solenoids.
-
Product
PXI 40Amp 14Volt 2xSPDT Automotive Relay
40-181-001
Relay
Models 40-180/181 are High Power Relay Modules available with 2 SPST, 4 SPST or 2 SPDT contacts. They are capable of switching inductive/capacitive loads up to 40A at 14VDC or 20A at 28VDC.The 40-180/181 High Power Relay Modules are suitable for switching heavy loads or for slaving large external relays, contactors and solenoids. In particular these relay modules are designed for automotive test applications requiring the switching of D.C. voltage at high current. The 28V version is suitable for truck system test applications.
-
Product
12-Ch 10A-250VAC RCV Power Distribution Unit
YAVAR438
Switch Module
- Hardware controlled Enable Input- 12 Power relays up to 10A 250VAC/DC and 300W or 2.700VA switching power- 12 10-mOhm shunt resistors.- 6 Switched 2-Pole sense channels- Single phase isolated or 3-Phases non-isolated switching capabilities, to or from the device under test (power or load)- VPC TriPaddle 96 pins connector.- NI LabView & TestStand driver.- .NET, C/C++, VB driver.- Soft Front panel for direct interface.- CAN Control or Ethernet (with Ethernet to CAN Gateway).- Self-test module available.- Form A
-
Product
CSI & DSI Protocol Generator
Envision X84 CSI&DSI
-
With comprehensive support for MIPI CSI-2v2 and DSI-2 specifications, Teledyne LeCroy’s Envision X84 generator platform provides the industry’s most accurate and reliable generation of MIPI camera and display protocols for fast debug, analysis and problem solving. The Envision X84 exerciser is loaded with innovative features that help uncover elusive protocol errors and is the intelligent choice for any camera and display validation needs. Using the same hardware platform as the Envision X84 C/D-PHY protocol analyzer, the Envision X84 offers the most flexible solution for MIPI Camera and Display validation and debug.
-
Product
Fault Locator
BIDOYNG
-
BIDOYNG fits into existing LV fuse positions using two LV fuses in parallel, creating a robust single-shot auto-recloser. The primary fuse carries the load current until a fault causes it to operate. Then, after a user programmed delay, the secondary fuse is switched in and the network re-energised without customer interruption.