Banks
-
Product
Mobile App Testing Company
-
ImpactQA’s Mobile Testing services offer comprehensive testing strategies that attend to device and network infrastructure. We offer an effective combination of manual and automated tools to cover functional and non-functional software issues. Selecting the right mobile test automation strategy is crucial for creating optimal mobile applications. At ImpactQA, we make sure you have the best options and choose the correct tools and processes suited for testing your mobile websites and native mobile apps. ImpactQA has wide experience in mobile testing for varied domains such as Insurance, Banking, Retail, Healthcare, E-learning, Media, BFSI, E-commerce, and Real Estate leveraging leading industry best practices and tools.
-
Product
PXI/PXIe RF Multiplexer, Dual 8-Channel, 3GHz, 75Ω, MCX
42-834A-102
Multiplexer Module
The 40-834A-102 (PXI) and 42-834A-102 (PXIe) are 75 Ohm 8 to 1 RF multiplexers with 2 banks in a single slot. They have been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss. The design of the 40/42-834A minimizes the injection of noise and unwanted signals into the signal path by careful attention to the mechanical and electrical design.
-
Product
4 2/3 Digital Resistance Meter
CS2-RS
-
CS2-RS Resistance Indicator has been designed with high accuracy measurement, display and communication of Ohm (2 wire) as like as Coil of motor or transformer.The meter supports Field Calibration function. It can be calibrated with sensor (Resistance) to meet machinery structure.We build flexible function as like as 3 bank (for multi-range scaling and set point) and 3 external control inputs meet to various testing equipment inquiry.They are also building in 4 Relay outputs, 3 External Control Inputs, 1 Analogue output and 1 RS485(Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission and communication for a wide range of machinery and testing equipments applications.
-
Product
Capacitive Bank Load
-
Supreme Instrument Laboratories
Capacitive Bank Load Three phase suitable for operation on 415/440 volts three phase AC 50Hz housed in well ventilated sheet steel cabinet with bakelite front panel, complete with indicating lamps, voltmeter to indicate the input voltage and Ammeters to indicate, the load. ON/OFF switch, discharge switch etc. available in continuously variable type.
-
Product
PXI MUX 1 Bank of 128 Channel 1 Pole
40-610-022-1/128/1
Multiplexer Module
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
Product
PXI Solid State MUX, 4 bank, 40 channel
40-680-004
Multiplexer Module
Based on FET switches, the multiplexers have no wear out mechanism and include fault protection that ensures the multiplexer automatically disconnects when PXI power is not applied. Available configurations for the 40-680 range vary from a single 160 to 1 MUX to a 20-bank, 8 to 1 MUX in a single PXI module.
-
Product
PXI Very High Density Versatile 2 Amp Multiplexer
40-612A-002
Multiplexer Module
The 40-612A Very High Density Versatile Multiplexer module features a wide range of software selectable switching configurations. It is especially useful where a number of high density multiplexers are required with the option of easily altering the channel count as a test system evolves. Typical applications include signal routing in ATE and data acquisition systems. The 40-612 module uses high quality electro-mechanical relays, connections are made via a front panel 160 pin DIN41612 connector. The module can be software configured into one of a large number of different multiplexer modes. Relays allow the multiplexer banks to be set in 1 or 2 pole mode and inter-bank switching enables the channel count to be increased up to a maximum of 128
-
Product
LXI Microwave Multiplexer, SP4T, 9-Bank, 40GHz, 50Ω, SMA-2.92, Terminated
60-803-509
Multiplexer Module
Our 60-803-509 is a 9 bank terminated SP4T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 40GHz. The 60-803 range is capable of supporting up to 14 banks of terminated 4 channel multiplexers it is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
PXI/PXIe RF Matrix, Dual 2x2, 2.5GHz, 75Ω, SMB
40-837A-002
Matrix Switch Module
The 40-837A-002 (PXI) and 42-837A-002 are 75Ω 2x2 RF matrices with 2 banks in a single slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40/42-837A modules.
-
Product
5KVA to 100KVA Industrial UPS (3Ø – 1Ø)
NSP Series 5KVA to 100KVA
-
- Designed for powering critical Industrial and IT systems- DSP controlled IGBT based PWM technology- Design topology enables N+1 parallel redundancy- Industrial grade high speed CAN bus communication- User Friendly Matrix LCD and LED mimic front control and digital monitoring- Fully rated make before break maintenance bypass operation- Optional break-less load transfer via static switch- Low harmonic distortion- High crest factor tolerance and dynamic stability- Lower TCO- Continuous full rated power at ambient as high as 45°C- N+1 Parallel operation of UPS without any common hardware- Advanced Communication Capability (RS485/Modbus/SNMP)- High branch fuse clearing capacity- On-line battery bank test without load disconnection- Compact, elegant, and light weight enclosure- Easy installation with wheels for maneuverability and front bottom terminals
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-215-016
Microwave Transfer Switch
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
PCI-6510, 32-Channel, ±30 VDC, Sink/Source Inputs, Bank-Isolated Digital I/O Device
779081-01
Digital I/O
The PCI-6510 is an industrial digital input interface, with a single bank of isolated channels. If a computer or application fault occurs, the PCI-6510 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions. Programmable input filters eliminate glitches/spikes and provide debouncing for digital switches/relays through a software-selectable digital filter.
-
Product
Perseus SDR HF Receiver
-
PERSEUS is a VLF-LF-HF receiver made by Microtelecom is based on a outstanding direct sampling digital architecture. It features a 14 bit 80 Ms/s analog-to-digital converter with an exceptional 76 dB SNR (BW = 40 MHz), an high-performance configurable FPGA digital down-converter with an up to 1 MS/s output sampling rate and a 480 MBit/s, high-speed USB 2.0 PC interface. Unlike in lower class direct sampling receivers, the PERSEUS RF analog front-end has been carefully designed for the most demanding users and includes a 0-30 dB, 10 dB steps attenuator, a low-loss 10 bands pass-band RF preselector filters bank, and an high dynamic preamplifier with a top-class input third-order Intercept Point of more than 30 dBm. The resulting third-order dynamic range is 103 dB for SSB signals (2.4 KHz BW) and 107 dB for CW signals (500 Hz BW).
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-415-001
Microwave Transfer Switch
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
LXI Microwave Multiplexer, SP6T, 9-Bank, 26.5GHz, 50Ω, SMA
60-800-309
Multiplexer Module
Our 60-800-309 is a 9 bank terminated SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 26.5GHz. The 60-800 range is capable of supporting up to 14 banks of 6 channel terminated multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
PXI/PXIe RF Multiplexer, Dual 4-Channel, Terminated Common, 3GHz, 50Ω, MCX
42-876A-102
Multiplexer Module
The 40-876A-102 (PXI) and 42-876A-102 (PXIe) are 50 Ohm 4 to 1 RF multiplexers with 2 banks in a single slot. Additionally, extra switching allows the common connection to be terminated into 50 Ohm, maintaining signal integrity. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
Product
LXI Microwave Multiplexer, 50Ω 6-Channel 7-Bank 26.5GHz SMA
60-801-307
Multiplexer Module
The 60-801-307 is a 6-channel, 7-bank RF multiplexer suitable for switching 50Ω signals up to 26.5GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
Product
LXI Microwave Multiplexer, SP4T, 9-Bank, 18GHz, 50Ω, SMA
60-803-109
Multiplexer Module
Our 60-803-109 is a 9 bank terminated SP4T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 18GHz. The 60-803 range is capable of supporting up to 14 banks of terminated 4 channel multiplexers it is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
LXI Microwave Multiplexer, 50Ω 6-Channel 1-Bank 26.5GHz SMA
60-801-301
Multiplexer Module
The 60-801-301 is a 6-channel, 1-bank RF multiplexer suitable for switching 50Ω signals up to 26.5GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
Product
PXI/PXIe RF Multiplexer, Dual 4-Channel, 3GHz, 75Ω, MCX
40-832A-102
Multiplexer Module
The 40-832A-102 (PXI) and 42-832A-102 (PXIe) are 75 Ohm 4 to 1 RF multiplexers with 2 banks in a single slot. They have been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss.
-
Product
AC Load Banks
-
Guangdong EMAX Electrical Co., Ltd.
We offer AC load banks in a variety of capacities and any voltage combination, with custom models including resistive, inductive, capacitive or resistive/reactive combination loads, all tailored to meet any load testing requirement.
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-210-010
Microwave Transfer Switch
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
PXI 36 Channel Data Comms MUX, 96-pin SCSI
40-735-912
Multiplexer Module
The 40-735 data communications multiplexer is designed for switching the data lines of serial interfaces (RS232, USB). Careful attention to the design of the module ensures that the switching system minimizes its impact on the transmission distance of USB1.1 interfaces. The MUX is available in 36:1 or 18:1 formats and enables a single source of serial data to be switched to one of 36 or 18 devices under test. This allows the data source to load information to, or receive information from, the device under test. This 36:1 version can be software configured into two independent 18 way MUXs enabling two separate sources of serial data to be connected to separate banks of 18 devices. The module is ideal for performing bulk testing of any device that relies on a serial data communications port to load software or control the device operation. It can also be used for a variety of other applications where ever a 2-pole low power MUX is required.
-
Product
LXI Microwave Multiplexer, 50Ω 6-Channel 12-Bank 40GHz SMA-2.9
60-801-412
Microwave Multiplexer
The 60-801-412 is a 6-channel, 12-bank RF multiplexer suitable for switching 50Ω signals up to 40GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
Product
PXI MUX 1 Bank of 64 Channel 1 Pole
40-610-021-1/64/1
Multiplexer Module
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
Product
LXI Microwave Multiplexer, 50Ω 4-Channel 5-Bank 6GHz SMA
60-802-005
Multiplexer Module
The 60-802-005 is a 4-channel, 5-bank RF multiplexer suitable for switching 50Ω signals up to 6GHz. It is part of a range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for between 1 and 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
Product
PXI/PXIe High Voltage Multiplexer, Quad 5-Channel, 2-Pole
42-321-121-HI
Multiplexer Module
The 40-321-121-HI (PXI) and 42-321-121-HI (PXIe) are quad 5-channel 2-pole high voltage multiplexers capable of hot or cold switching up to 1000 V peak. They are also available in a range of bank sizes with 1 or 2 poles and channel counts between 4 and 48. High quality reed relays are used throughout.
-
Product
Acute High Voltage Differential Probe, 50x/500x, 25MHz, 3500V
ADP5025
-
*USB Powered (or Power Bank)*Bandwidth up to 25 MHz*Overrange Indicator*Audible Overrange Alarm*Bandwidth Limit : 5 MHz / Full*Can be used by any DSO which has the USB port(s).*EC Declaration: EN 61010-031:2002 +A1:2008*Double-layer wire for power insulation
-
Product
LXI Microwave Multiplexer, SP4T, 11-Bank, 50GHz, 50Ω, SMA-2.4
60-803-711
Multiplexer Module
Our 60-803-711 is a 11 bank terminated SP4T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 50GHz. The 60-803 range is capable of supporting up to 14 banks of terminated 4 channel multiplexers it is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
PXI/PXIe High Voltage Multiplexer, Dual 23-Channel, 2-Pole
40-321-128-HI
Multiplexer Module
The 40-321-128-HI (PXI) and 42-321-128-HI (PXIe) are dual 23-channel 2-pole high voltage multiplexers capable of hot or cold switching up to 1000 V peak. They are also available in a range of bank sizes with 1 or 2 poles and channel counts between 4 and 48. High quality reed relays are used throughout.