Transfer Standards
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-510-015
-
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-515-013
-
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
PXI Hybrid Coaxial Switch: DC to 40 GHz, Dual Transfer
M9156CH40
Switch Module
The Keysight M9156CH40 PXI hybrid dual transfer switch module provides an exceptional 0.03 dB insertion loss repeatability, high isolation, low SWR with a long operating life up to 10 million cycles.
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-315-013
-
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
PXI Microwave Transfer Switch, Single, 26.5GHz, 50Ω, SMA
40-782B-531
Switch Module
The 40-782B-531 (PXI) and 42-782B-531 (PXIe) single transfer switches are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50Ω and a maximum operating frequency of 26.5GHz. Connections are made via front panel mounted high quality SMA coaxial connectors.
-
Product
Standard Connectors
-
C.C.P. Contact Probes Co., LTD.
The Standard Connector Series aims to offer a comprehensive selection of internationallycompatible connectors. Its smart design and simple structure makes it very cost effectiveeven at small volumes.
-
Product
Standard Industrial Ovens
-
ESPEC offers two types of standard models: the space-saving PV vertical ovens and the PH horizontal ovens. Both provide horizontal airflow for even exposure to all samples. Control constancy as low as ±0.1°C and uniformity as low as ±0.5°C ensures accurate operation. An exhaust damper is included to ventilate the oven and allow quick cool-down.
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-210-008
-
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
IEC Standard Burden Sets (Current)
IEC Burden Sets
-
Testing and calibrating current transformers often requires standard burdens of reliable accuracy and stability, and burdens that are immune to stray fields and harmonics. These burden sets have been carefully designed to meet these requirements. They also provide the standard burdens required for the testing of current transformers for metering service, and for the testing (within the current rating provided by the sets) of current transformers for relaying applications, all as called for by IEC (International Electrotechnical Commission) Publication 185: 1987.
-
Product
PCI Standard Programmable Resistor Cards
-
Pickering's PCI Standard Programmable Resistor Cards include fully programmable resistor and potentiometer cards for applications such as sensor emulation that require fine adjustment with a resolution down to 0.25 Ohm. All of our Programmable Resistor Cards can easily be formed to make Programmable Potentiometers by connecting two channels in series, using the unconnected terminals as the A and B connections and the link between the two channels as the wiper connection.
-
Product
Power And Data Transfer
-
Cable reels & slip ring assemblies for reliable power and data transfer in mining, construction and material handling applications.
-
Product
Standard Accessory Replacement Kit for PP017/PP018
PKIT4-5MM-101
-
Standard Accessory Replacement Kit for PP017/PP018.
-
Product
PXI Dual Transfer Switch 18GHz 50Ω SMA
40-782-522
Switch Module
The 40-780 Microwave switching module consists of one, two, three or four changeover switches capable of switching frequencies to 18GHz (optionally to 67GHz) in 50Ω or 2.5GHz in 75Ω. The 40-782 module consists of one or two microwave transfer switches. It has a characteristic impedance of 50Ω and is available in versions with maximum operating frequencies of 18GHz, 26.5GHz or 40GHz.
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-510-003
-
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-215-007
-
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-510-012
-
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-310-014
-
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-215-001
-
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
PXI/PXIe Microwave Transfer Switch, Dual, 50GHz, 50Ω, SMA-2.4
40-782B-552
Switch Module
The 40-782B-552 (PXI) and 42-782B-552 (PXIe) dual transfer switches are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50Ω and a maximum operating frequency of 50GHz. Connections are made via front panel mounted high quality SMA-2.4 coaxial connectors.
-
Product
PXI Dual Transfer Switch 40GHz 50Ω SMA-2.9
40-782-542
Switch Module
The 40-780 Microwave switching module consists of one, two, three or four changeover switches capable of switching frequencies to 18GHz (optionally to 67GHz) in 50Ω or 2.5GHz in 75Ω. The 40-782 module consists of one or two microwave transfer switches. It has a characteristic impedance of 50Ω and is available in versions with maximum operating frequencies of 18GHz, 26.5GHz or 40GHz.
-
Product
Multiparameter CTD with a Wide Choice of Standard Sensors.
MIDAS CTD+
-
Featuring Valeport’s latest 400 Series electronics, the CTD+ will sample all fitted sensors at exactly the same instant, at up to 8Hz. Advanced setup software allows a variety of sampling regimes including burst modes, delay starts and conditional sampling. Available with up to 64Mbyte memory and internal battery pack, as well as a selection of real-time output formats, the CTD+ may be used with Valeport’s own water bottle carousel.
-
Product
Time & Frequency Standards
Meridian II Precision TimeBase
-
The Meridian II Precision TimeBase is a modular, network-centric, time & frequency standard that provides the most precise and stable, GPS-synchronized, time & frequency outputs in the world. Unlike our competitors, we fully specify the performance of Meridian II and back it up with published data measured at NIST.
-
Product
Serv-U Managed File Transfer Server
-
Enhance security and control over file transfers in and outside your organization
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2J40
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
LXI 50Ω Microwave Transfer Switch
60-808-315-014
-
These LXI (Ethernet-controlled) Microwave Transfer Switches are suitable for routing 50 Ω signals up to 50 GHz. With up to 16 switch banks, they are ideal for constructing complex microwave switching systems for many applications. Connection is by front panel mounted SMA. SMA 2.9 or SMA 2.4 connectors.
-
Product
Standard 1.68 (48.00) - 3.20 (91.00) General Purpose Probe
HPA-52D
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 250,000Overall Length (mil): 629Overall Length (mm): 15.98
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50L-QG-75R
High Frequency Probe
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,637Overall Length (mm): 41.58
-
Product
Pyranometer First Class standard (ISO 9060 / WMO)
CMP 6
-
The CMP 6 pyranometer is intended for routine global solar radiation measurement research on a plane/level surface.Fully compliant with ISO-9060 specification for a First Class pyranometer, the CMP 6 features a sixty-four thermocouple junction (series connected) sensing element. The sensing element is coated with a highly stable carbon based non organic coating, which delivers excellent spectral absorption and long term stability characteristics
-
Product
Automatic Transfer Of Measured Data
imc LINK
-
Around the corner, out in the garage, or across the globe, with imc LINK you can have full access to your data without the hassle and expense of traveling to your test site, or tracking down your test vehicles.





























